MR to ultrasound registration for image-guided prostate interventions

被引:130
|
作者
Hu, Yipeng [1 ]
Ahmed, Hashirn Uddin [2 ]
Taylor, Zeike [1 ]
Allen, Clare [3 ]
Emberton, Mark [2 ]
Hawkes, David [1 ]
Barratt, Dean [1 ]
机构
[1] UCL, Ctr Med Image Comp, London, England
[2] UCL, Dept Urol, Div Surg & Intervent Sci, London, England
[3] Univ Coll London Hosp, Dept Radiol, London, England
基金
英国工程与自然科学研究理事会;
关键词
Image registration; Biomechanical modelling; Statistical shape modelling; Minimum-invasive interventions; Prostate cancer; INTENSITY-FOCUSED ULTRASOUND; FINITE-ELEMENT-ANALYSIS; FOCAL THERAPY; RADICAL PROSTATECTOMY; DEFORMABLE REGISTRATION; AUTOMATIC SEGMENTATION; SURGICAL SIMULATION; CANCER; BIOPSY; TIME;
D O I
10.1016/j.media.2010.11.003
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A deformable registration method is described that enables automatic alignment of magnetic resonance (MR) and 3D transrectal ultrasound (TRUS) images of the prostate gland. The method employs a novel "model-to-image" registration approach in which a deformable model of the gland surface, derived from an MR image, is registered automatically to a TRUS volume by maximising the likelihood of a particular model shape given a voxel-intensity-based feature that represents an estimate of surface normal vectors at the boundary of the gland. The deformation of the surface model is constrained by a patient-specific statistical model of gland deformation, which is trained using data provided by biomechanical simulations. Each simulation predicts the motion of a volumetric finite element mesh due to the random placement of a TRUS probe in the rectum. The use of biomechanical modelling in this way also allows a dense displacement field to be calculated within the prostate, which is then used to non-rigidly warp the MR image to match the TRUS image. Using data acquired from eight patients, and anatomical landmarks to quantify the registration accuracy, the median final RMS target registration error after performing 100 MR-TRUS registrations for each patient was 2.40 mm. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:687 / 703
页数:17
相关论文
共 50 条
  • [1] Two Solutions for Registration of Ultrasound to MRI for Image-Guided Prostate Interventions
    Moradi, Mehdi
    Janoos, Firdaus
    Fedorov, Andriy
    Risholm, Petter
    Kapur, Tina
    Wolfsberger, Luciant D.
    Nguyen, Paul L.
    Tempany, Clare M.
    Wells, William M.
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1129 - 1132
  • [2] System for MR image-guided prostate interventions: Canine study
    Susil, RC
    Krieger, A
    Derbyshire, JA
    Tanacs, A
    Whitcomb, LL
    Fichtinger, G
    Atalar, E
    [J]. RADIOLOGY, 2003, 228 (03) : 886 - 894
  • [3] MR to Ultrasound Image Registration for Guiding Prostate Biopsy and Interventions
    Hu, Yipeng
    Ahmed, Hashim Uddin
    Allen, Clare
    Pendse, Doug
    Sahu, Mahua
    Emberton, Mark
    Hawkes, David
    Barratt, Dean
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 787 - +
  • [4] Automatic Deformable MR-Ultrasound Registration for Image-Guided Neurosurgery
    Rivaz, Hassan
    Chen, Sean Jy-Shyang
    Collins, D. Louis
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 366 - 380
  • [5] A MR-TRUS Registration Method for Ultrasound-Guided Prostate Interventions
    Yang, Xiaofeng
    Rossi, Peter
    Mao, Hui
    Jani, Ashesh B.
    Ogunleye, Tomi
    Curran, Walter J.
    Liu, Tian
    [J]. MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [6] THE USE OF A PROSTATE STENT FOR MR-CT REGISTRATION IN IMAGE-GUIDED RADIOTHERAPY OF PROSTATE CANCER
    Oestergaard, L. R.
    Eskildsen, S. F.
    Nielsen, J.
    Holmberg, A.
    Larsen, E. Hojkjaer
    Fabrin, K.
    Fisker, R.
    Carl, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S417 - S418
  • [7] Navigation concepts for MR image-guided interventions
    Moche, Michael
    Trampel, Robert
    Kahn, Thomas
    Busse, Harald
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (02) : 276 - 291
  • [8] Image-guided robotic interventions for prostate cancer
    Sridhar, Ashwin N.
    Hughes-Hallett, Archie
    Mayer, Erik K.
    Pratt, Philip J.
    Edwards, Philip J.
    Yang, Guang-Zhong
    Darzi, Ara W.
    Vale, Justin A.
    [J]. NATURE REVIEWS UROLOGY, 2013, 10 (08) : 452 - 462
  • [9] Image-guided robotic interventions for prostate cancer
    Ashwin N. Sridhar
    Archie Hughes-Hallett
    Erik K. Mayer
    Philip J. Pratt
    Philip J. Edwards
    Guang-Zhong Yang
    Ara W. Darzi
    Justin A. Vale
    [J]. Nature Reviews Urology, 2013, 10 : 452 - 462
  • [10] Image-to-Physical Registration for Image-Guided Interventions Using 3-D Ultrasound and an Ultrasound Imaging Model
    King, Andrew P.
    Ma, Ying-Liang
    Yao, Cheng
    Jansen, Christian
    Razavi, Reza
    Rhode, Kawal S.
    Penney, Graeme P.
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 188 - 201