Dosimetric comparison between intra-cavitary breast brachytherapy techniques for accelerated partial breast irradiation and a novel stereotactic radiotherapy device for breast cancer: GammaPodTM

被引:11
|
作者
Oden, Jakob [1 ]
Toma-Dasu, Iuliana [2 ,3 ]
Yu, Cedric X. [4 ,5 ]
Feigenberg, Steven J. [5 ]
Regine, William F. [5 ]
Mutaf, Yildirim D. [5 ]
机构
[1] Karolinska Univ Hosp, Dept Med Phys, Stockholm, Sweden
[2] Stockholm Univ, S-10691 Stockholm, Sweden
[3] Karolinska Inst, Stockholm, Sweden
[4] Xcision Med Syst LLC, Columbia, MD USA
[5] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 13期
关键词
CONTURA MULTILUMEN BALLOON; MAMMOSITE; MULTICATHETER; TOXICITY; CATHETER; SKIN;
D O I
10.1088/0031-9155/58/13/4409
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The GammaPod (TM) device, manufactured by Xcision Medical Systems, is a novel stereotactic breast irradiation device. It consists of a hemispherical source carrier containing 36 Cobalt-60 sources, a tungsten collimator with two built-in collimation sizes, a dynamically controlled patient support table and a breast immobilization cup also functioning as the stereotactic frame for the patient. The dosimetric output of the GammaPod (TM) was modelled using a Monte Carlo based treatment planning system. For the comparison, three-dimensional (3D) models of commonly used intra-cavitary breast brachytherapy techniques utilizing single lumen and multi-lumen balloon as well as peripheral catheter multi-lumen implant devices were created and corresponding 3D dose calculations were performed using the American Association of Physicists in Medicine Task Group-43 formalism. Dose distributions for clinically relevant target volumes were optimized using dosimetric goals set forth in the National Surgical Adjuvant Breast and Bowel Project Protocol B-39. For clinical scenarios assuming similar target sizes and proximity to critical organs, dose coverage, dose fall-off profiles beyond the target and skin doses at given distances beyond the target were calculated for GammaPod (TM) and compared with the doses achievable by the brachytherapy techniques. The dosimetric goals within the protocol guidelines were fulfilled for all target sizes and irradiation techniques. For central targets, at small distances from the target edge (up to approximately 1 cm) the brachytherapy techniques generally have a steeper dose fall-off gradient compared to GammaPod (TM) and at longer distances (more than about 1 cm) the relation is generally observed to be opposite. For targets close to the skin, the relative skin doses were considerably lower for GammaPod (TM) than for any of the brachytherapy techniques. In conclusion, GammaPod (TM) allows adequate and more uniform dose coverage to centrally and peripherally located targets with an acceptable dose fall-off and lower relative skin dose than the brachytherapy techniques considered in this study.
引用
下载
收藏
页码:4409 / 4421
页数:13
相关论文
共 50 条
  • [41] Comparison of survival and regional failure between accelerated partial breast irradiation and whole breast irradiation
    Shah, Chirag
    Ben Wilkinson, J.
    Lyden, Maureen
    Mbah, Alfred
    Keisch, Martin
    Beitsch, Peter
    Vicini, Frank A.
    BRACHYTHERAPY, 2012, 11 (04) : 311 - 315
  • [42] Comparison of accelerated partial breast irradiation via multicatheter interstitial brachytherapy versus whole breast radiation
    Ferraro, Daniel J.
    Garsa, Adam A.
    DeWees, Todd A.
    Margenthaler, Julie A.
    Naughton, Michael
    Aft, Rebecca
    Gillanders, William E.
    Eberlein, Timothy
    Matesa, Melissa A.
    Zoberi, Imran
    RADIATION ONCOLOGY, 2012, 7
  • [43] Comparison of accelerated partial breast irradiation via multicatheter interstitial brachytherapy versus whole breast radiation
    Daniel J Ferraro
    Adam A Garsa
    Todd A DeWees
    Julie A Margenthaler
    Michael Naughton
    Rebecca Aft
    William E Gillanders
    Timothy Eberlein
    Melissa A Matesa
    Imran Zoberi
    Radiation Oncology, 7
  • [44] ACCELERATED PARTIAL BREAST IRRADIATION: A DOSIMETRIC COMPARISON OF PERI- AND POSTOPERATIVE IMPLANTS
    Loessl, K.
    Cihoric, N.
    Isaak, B.
    Terribilini, D.
    Aebersold, D. M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S250 - S250
  • [45] Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
    Rault, Erwann
    Lacornerie, Thomas
    Hong-Phuong Dang
    Crop, Frederik
    Lartigau, Eric
    Reynaert, Nick
    Pasquier, David
    RADIATION ONCOLOGY, 2016, 11
  • [46] Possibility of replacement of whole breast radiotherapy with accelerated partial breast irradiation for treatment of early stage breast cancer
    Utehina, O.
    Popovs, S.
    Berzins, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S287 - S288
  • [47] Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
    Erwann Rault
    Thomas Lacornerie
    Hong-Phuong Dang
    Frederik Crop
    Eric Lartigau
    Nick Reynaert
    David Pasquier
    Radiation Oncology, 11
  • [48] Dosimetric characteristics of accelerated partial breast irradiation by interstitial multicatheter brachytherapy with intraoperative free-hand implantation in the treatment of early breast cancer
    Li, Chuan
    Lin, Jia-Fu
    Yeh, Hui Ling
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 27 - 34
  • [49] A Dosimetric Comparison for Adaptive Cone-Beam CT and MRI Based Radiotherapy for Stereotactic Partial Breast Irradiation
    Parsons, D.
    Chen, L.
    Lee, H.
    Zhang, Y.
    Cai, B.
    Zhuang, T.
    Hrycushko, B.
    Park, C.
    Gonzalez, Y.
    Zhong, X.
    Visak, J.
    Nwachukwu, C.
    Kim, N.
    Alluri, P.
    Rahimi, A.
    Lin, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E712 - E712
  • [50] Dosimetric experience with accelerated partial breast irradiation using image-guided interstitial brachytherapy
    Major, Tibor
    Froehlich, Georgina
    Loevey, Katalin
    Fodor, Janos
    Polgar, Csaba
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 48 - 55