Pupil Center as a Function of Pupil Diameter

被引:1
|
作者
Ahmed, Zaheer [1 ]
Mardanbegi, Diako [1 ]
Hansen, Dan Witzner [1 ]
机构
[1] IT Univ Copenhagen, Copenhagen, Denmark
关键词
image processing; eye tracking; gaze estimation; pupil dynamics; human computer interaction;
D O I
10.1145/2857491.2857536
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We investigate the gaze estimation error induced by pupil size changes using simulated data. We investigate the influence of pupil diameter changes on estimated gaze point error obtained by two gaze estimation models. Simulation data show that at wider viewing angles and at small eye-camera distances, error increases with increasing pupil sizes. The maximum error recorded for refracted pupil images is 2:4 degrees of visual angle and 1:5 degrees for non-refracted pupil projections.
引用
收藏
页码:283 / 286
页数:4
相关论文
共 50 条
  • [31] Dark-adapted Pupil Diameter as a Function of Age Measured With the NeurOptics Pupillometer
    Bradley, Jay C.
    Bentley, Karl C.
    Mughal, Aleem I.
    Bodhireddy, Hari
    Brown, Sandra M.
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (03) : 202 - 207
  • [32] Pupil diameter measurement errors as a function of gaze direction in corneal reflection eyetrackers
    Julie Brisson
    Marc Mainville
    Dominique Mailloux
    Christelle Beaulieu
    Josette Serres
    Sylvain Sirois
    Behavior Research Methods, 2013, 45 : 1322 - 1331
  • [33] Exploring the Effect of Virtual Depth on Pupil Diameter
    Iskander, Julie
    Attia, Mohammed
    Saleh, Khaled
    Abobakr, Ahmed
    Nahavandi, Darius
    Hossny, Mohammed
    Nahavandi, Saeid
    2019 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC), 2019, : 1849 - 1854
  • [34] Investigation of the Pupil Diameter Differences in Anisometropic Amblyopia
    Kocamis, Sucattin Ilker
    Cakmak, Hasan Basri
    Cagil, Nurullah
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (01): : 45 - 50
  • [35] EFFECT OF NARCOTIC ANTAGONISTS ON PUPIL DIAMETER OF NONADDICTS
    ELLIOTT, HW
    WAY, EL
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1961, 2 (06) : 713 - &
  • [36] Blood pressure and pupil diameter measures of deception
    Kircher, J
    Podlesny, J
    Bernhardt, P
    Bell, B
    Packard, T
    PSYCHOPHYSIOLOGY, 2000, 37 : S19 - S19
  • [37] The relationship between pupil diameter and decentration in myopia
    Nuzzi, R
    Finazzo, C
    Francone, L
    EYE, 1997, 11 (5) : 729 - 732
  • [38] Automatic Stress Classification With Pupil Diameter Analysis
    Pedrotti, Marco
    Mirzaei, Mohammad Ali
    Tedesco, Adrien
    Chardonnet, Jean-Remy
    Merienne, Frederic
    Benedetto, Simone
    Baccino, Thierry
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2014, 30 (03) : 220 - 236
  • [39] A pupil diameter measurement system for accident prevention
    Shinoda, Takayuki
    Kato, Masami
    2006 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS, VOLS 1-6, PROCEEDINGS, 2006, : 1699 - +
  • [40] THE EFFECT OF PUPIL CENTRATION AND DIAMETER ON OCULAR PERFORMANCE
    WALSH, G
    CHARMAN, WN
    VISION RESEARCH, 1988, 28 (05) : 659 - 665