Biomechanical analysis of four augmented fixations of plate osteosynthesis for comminuted mid-shaft clavicle fracture: A finite element approach

被引:7
|
作者
Ni, Ming [1 ,2 ]
Zhang, Fangfang [3 ]
Mei, Jiong [3 ]
Lin, Chia-Ying James [2 ]
Gruber, Stacey M. S. [2 ]
Niu, Wenxin [4 ]
Wong, Duo Wai-Chi [5 ,6 ]
Zhang, Ming [5 ,6 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Dept Orthopaed, Pudong New Area PeoplesHosp, Shanghai 201299, Peoples R China
[2] Univ Cincinnati, Coll Engn & Appl Sci, Dept Biomed Engn, Cincinnati, OH 45221 USA
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Orthopaed, 600 Yishan Rd, Shanghai 200233, Peoples R China
[4] Tongji Univ, Yangzhi Rehabil Hosp, Res Ctr Disabled Rehabil Med, Sch Med, Shanghai 200129, Peoples R China
[5] Hong Kong Polytech Univ, Dept Biomed Engn, Kowloon, Hong Kong 999077, Peoples R China
[6] Hong Kong Polytech Univ, Shenzhen Res Inst, Shenzhen 518057, Guangdong, Peoples R China
关键词
clavicle fracture; internal fixation; plate; interfragmentary screw; cerclage wiring; biomechanics; finite element simulation; LAG SCREW; COMPLICATIONS; SUPERIOR;
D O I
10.3892/etm.2020.8898
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Sufficient stabilization of comminuted mid-shaft clavicle fractures via plate fixation is difficult to achieve. Various augmentations, including interfragmentary screws and cerclage wiring, have been adopted to reinforce fixation stability. The present study aimed to assess the biomechanical stability of augmented plate fixations using the finite element method. First, a clavicle fracture model was created from CT data. Fixation was then induced using a locking compressive plate (LCP) with the following four augmentations: i) Double inner cerclage wirings (DICW), ii) double outer cerclage wirings (DOCW), iii) a single interfragmentary screw (SIS) and iv) double interfragmentary screws (DIS). Compressive and bending forces of 100 N were subsequently applied at the acromial region of the clavicle. The stress distribution, displacement and fracture micro-motions of the model were assessed and compared. The DOCW resulted in the highest stress exerted on the LCP, followed by SIS, DICW and DIS. For the clavicle fracture, DICW, DOCW and SIS resulted in high stress levels. However, DIS fixation alone resulted in levels of stress that were below the yield strength of cortical bone. Displacement analysis revealed that DOCW fixation resulted in the greatest degree of displacement and fracture micro-motions, followed by SIS, DICW and DIS. The results indicated that SIS, DIS and DOCW may be used as augmentations of LCP fixation for comminuted mid-shaft clavicle fractures. However, DIS was the recommended augmentation due to it exerting the lowest stress and the highest stability compared with the other fixations. The DICW may be used to aid fracture reduction and plate placement in surgery but should be avoided for permanent fixation.
引用
收藏
页码:2106 / 2112
页数:7
相关论文
共 50 条
  • [21] Comparison of supraclavicular nerve injuries after clavicle mid-shaft surgery via minimally invasive plate osteosynthesis versus open reduction and internal fixation
    Sang-Hun Ko
    Myung-Seo Kim
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1895 - 1902
  • [22] Management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis
    Yanbin Zhu
    Ye Tian
    Tianhua Dong
    Wei Chen
    Fei Zhang
    Yingze Zhang
    International Orthopaedics, 2015, 39 : 319 - 328
  • [23] Comparison of supraclavicular nerve injuries after clavicle mid-shaft surgery via minimally invasive plate osteosynthesis versus open reduction and internal fixation
    Ko, Sang-Hun
    Kim, Myung-Seo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (08) : 1895 - 1902
  • [24] Management of the mid-shaft clavicle fractures using plate fixation versus intramedullary fixation: an updated meta-analysis
    Zhu, Yanbin
    Tian, Ye
    Dong, Tianhua
    Chen, Wei
    Zhang, Fei
    Zhang, Yingze
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (02) : 319 - 328
  • [25] Screw Stress Distribution in a Clavicle Fracture with Plate Fixation: A Finite Element Analysis
    Alito, Angelo
    Fenga, Domenico
    Tropeano, Giada
    Milardi, Demetrio
    Leonetti, Danilo
    Migliorato, Alba
    Tisano, Adriana
    D'Andrea, Danilo
    Filardi, Vincenzo
    BIOENGINEERING-BASEL, 2023, 10 (12):
  • [26] Intramedullary devices fixation versus plate fixation for adult displaced mid-shaft clavicle fractures: an update meta-analysis
    Zhang, Xiao
    Geng, Tao
    Xue, Haitao
    Zhang, Wenqiang
    Yin, Yingchao
    Jiang, Zhen
    Hu, Zeqing
    Luo, Tong
    Zhang, Guisheng
    Xu, Yi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (02): : 1840 - 1846
  • [27] Biomechanical efficacy of four different dual screws fixations in treatment of talus neck fracture: a three-dimensional finite element analysis
    Zhengrui Fan
    Jianxiong Ma
    Jian Chen
    Baocheng Yang
    Ying Wang
    Haohao Bai
    Lei Sun
    Yan Wang
    Bin Lu
    Ben-chao Dong
    Aixian Tian
    Xinlong Ma
    Journal of Orthopaedic Surgery and Research, 15
  • [28] Biomechanical efficacy of four different dual screws fixations in treatment of talus neck fracture: a three-dimensional finite element analysis
    Fan, Zhengrui
    Ma, Jianxiong
    Chen, Jian
    Yang, Baocheng
    Wang, Ying
    Bai, Haohao
    Sun, Lei
    Wang, Yan
    Lu, Bin
    Dong, Ben-chao
    Tian, Aixian
    Ma, Xinlong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [29] Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
    Jung-Soo Lee
    Kwang Gi Kim
    Yong-Cheol Yoon
    Scientific Reports, 13
  • [30] Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
    Lee, Jung-Soo
    Kim, Kwang Gi
    Yoon, Yong-Cheol
    SCIENTIFIC REPORTS, 2023, 13 (01)