MEASUREMENT OF ANKLE PLANTAR FLEXOR SPASTICITY FOLLOWING STROKE: ASSESSMENT OF A NEW QUANTITATIVE TOOL

被引:3
|
作者
Chino, Naoichi [1 ]
Muraoka, Yoshihiro [1 ]
Ishihama, Hiroki [1 ]
Ide, Masaru [1 ]
Ushijima, Riousuke [1 ]
Basford, Jeffrey R. [2 ]
机构
[1] Eisei Kai Rehab Res & Dev Ctr, Hachioji, Tokyo 1930942, Japan
[2] Mayo Clin, Dept Phys Med & Rehabil, Rochester, MN USA
关键词
Modified Ashworth Scale; muscle tone; measurement; spasticity; QUANTIFICATION;
D O I
10.2340/16501977-1991
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the ability of a newly developed portable instrument (the Electric Spastic Ankle Measure (E-SAM)) to quantitatively measure ankle plantar flexor muscle tone and spasticity. Design: Comparison of quantitative measurements of the ESAM with those obtained manually with the Modified Ashworth Scale (MAS). Participants: Seven adult men with stroke of more than 8 months' duration with a MAS score of 3, and 7 healthy age-matched control subjects. Main outcome measures: Quantitative measurements of the reactive and viscoelastic components of muscle tonus and spasticity. Results: Analysis of the pooled data of all subjects revealed 2 components: an initial negative peak (indicating viscoelasticity), and subsequent positive peaks (denoting reactive contractions of the plantar flexor muscles). Positive, reactive contraction, peaks of the subjects with stroke were significantly higher than those of age-matched controls (p<0.01, t-test). Conclusion: The E-SAM appears to provide meaningful information on muscle tone and spasticity that is more specific and quantitative than that obtained with the MAS. While further study is necessary, this instrument shows promise as an easy-to-use clinical and research tool for the measurement of spasticity and muscle viscosity.
引用
收藏
页码:753 / 755
页数:3
相关论文
共 50 条
  • [21] Assessment of post-stroke elbow flexor spasticity in different forearm positions
    Sengul, Ilker
    Askin, Ayhan
    Bayram, Korhan
    Tosun, Aliye
    SOMATOSENSORY AND MOTOR RESEARCH, 2018, 35 (3-4): : 218 - 222
  • [22] Assessment of Spasticity With Sonoelastography Following Stroke: A Feasibility Study
    Kesikburun, Serdar
    Yasar, Evren
    Adiguzel, Emre
    Guzelkucuk, Umut
    Alaca, Ridvan
    Tan, Arif Kenan
    PM&R, 2015, 7 (12) : 1254 - 1260
  • [23] Reliability of the Modified Ashworth Scale in the assessment of plantar flexor muscle spasticity in patients with traumatic brain injury
    Allison, SC
    Abraham, LD
    Petersen, CL
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1996, 19 (01) : 67 - 78
  • [24] Changes in the activation and function of the ankle plantar flexor muscles due to gait retraining in chronic stroke survivors
    Knarr, Brian A.
    Kesar, Trisha M.
    Reisman, Darcy S.
    Binder-Macleod, Stuart A.
    Higginson, Jill S.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2013, 10 : 12
  • [25] The Ankle Lunge Test for measurement of dorsiflexion in individuals following stroke; reliability, validity and evaluation of change following intervention for spasticity of the lower limb
    Simondson, Janine
    Simondson, David
    Formby, Claire
    Brock, Kim
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2022, 27 (01)
  • [26] Changes in the activation and function of the ankle plantar flexor muscles due to gait retraining in chronic stroke survivors
    Brian A Knarr
    Trisha M Kesar
    Darcy S Reisman
    Stuart A Binder-Macleod
    Jill S Higginson
    Journal of NeuroEngineering and Rehabilitation, 10
  • [27] KAPS (kinematic assessment of passive stretch): a tool to assess elbow flexor and extensor spasticity after stroke using a robotic exoskeleton
    Centen, Andrew
    Lowrey, Catherine R.
    Scott, Stephen H.
    Yeh, Ting-Ting
    Mochizuki, George
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14
  • [28] KAPS (kinematic assessment of passive stretch): a tool to assess elbow flexor and extensor spasticity after stroke using a robotic exoskeleton
    Andrew Centen
    Catherine R. Lowrey
    Stephen H. Scott
    Ting-Ting Yeh
    George Mochizuki
    Journal of NeuroEngineering and Rehabilitation, 14
  • [29] RELIABILITY OF A NEW SCALE FOR MEASUREMENT OF SPASTICITY IN STROKE PATIENTS
    Li, Fang
    Wu, Yuedi
    Xiong, Li
    JOURNAL OF REHABILITATION MEDICINE, 2014, 46 (08) : 746 - 753
  • [30] Reliability of a new scale for the measurement of spasticity in stroke patients
    Li, F.
    Wu, Y.
    Li, X.
    PROCEEDINGS OF THE 7TH WORLD CONGRESS OF INTERNATIONAL SOCIETY OF PHYSICAL AND REHABILITATION MEDICINE, 2013, : 3 - 4