A new tapered regenerator used for pulse tube refrigerator and its optimization

被引:7
|
作者
Liu Ying-wen [1 ]
He Ya-ling [1 ]
机构
[1] Xian Jiaotong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Pulse tube refrigerator; Tapered regenerator; Cryogenics; Numerical simulation; Enthalpy flow theory;
D O I
10.1016/j.cryogenics.2008.07.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
The results of numerical simulation and theoretical analysis of the local heat transfer coefficient and the average remaining gas mass with the length of a uniform cross-sectional regenerator are presented in this paper. It was found that there are some serious thermodynamic limitations in the uniform cross-sectional regenerator and thus the efficiency of the regenerator can not fully exert. In order to further reduce the loss of the regenerator and improve the heat transfer of the cold end, the authors bring forward a design principle: the variation trend of the cross-section of the regenerator will be consistent with the direction of the temperature gradient, and introduce two kinds of tapered regenerators including convergent and divergent in order to improve the performance of the pulse tube refrigerator. Two models were introduced with governing equations to simulate two kinds of pulse tube refrigerators with tapered regenerator. The simulation results showed that there exist an optimum cone angle for tapered regenerator. When the cone angle is close to a certain value, the pulse tube refrigerator with convergent type regenerator can improve the performance which means increasing the cooling power, decreasing the working power, and eliminating the DC-flow rate. But the divergent type regenerator deteriorates the performance. in order to further validate the feasibility of this structural design, based on the enthalpy flow theory, the mechanism of the improvement of the performance of a PTR with tapered regenerator is systemically analyzed. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:483 / 491
页数:9
相关论文
共 50 条
  • [41] Valved pulse tube refrigerator development
    Richardson, R.N., 1600, (29):
  • [42] Vibration generation in a pulse tube refrigerator
    Riabzev, S. V.
    Veprik, A. M.
    Vilenchik, H. S.
    Pundak, N.
    CRYOGENICS, 2009, 49 (01) : 1 - 6
  • [43] An experimental investigation of the pulse tube refrigerator
    Koh, DY
    Park, SJ
    Lee, SJ
    Yeom, HK
    Hong, YJ
    Jeong, SK
    CRYOCOOLERS 9, 1997, : 239 - 245
  • [44] ISOTHERMAL MODEL OF PULSE TUBE REFRIGERATOR
    ZHU, SW
    CHEN, ZQ
    CRYOGENICS, 1994, 34 (07) : 591 - 595
  • [45] Step piston pulse tube refrigerator
    Zhu, Shaowei
    CRYOGENICS, 2014, 64 : 63 - 69
  • [46] Thermoacoustic analysis of a pulse tube refrigerator
    Biwa, T.
    26TH INTERNATIONAL CONFERENCE ON LOW TEMPERATURE PHYSICS (LT26), PTS 1-5, 2012, 400
  • [47] Numerical method of inertance tube pulse tube refrigerator
    Zhu, SW
    Matsubara, Y
    CRYOGENICS, 2004, 44 (09) : 649 - 660
  • [48] Multi-objective optimization of a stirling-type pulse tube refrigerator
    Jafari, S.
    Mohammadi, B.
    Boroujerdi, A. A.
    CRYOGENICS, 2013, 55-56 : 53 - 62
  • [49] Optimization of a two stage pulse tube refrigerator for the integrated current lead system
    Maekawa, R.
    Matsubara, Y.
    Okada, A.
    Takami, S.
    Konno, M.
    Tomioka, A.
    Imayoshi, T.
    Hayashi, H.
    Mito, T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 101 - +
  • [50] Study for coating effect of various materials in pulse tube of pulse tube refrigerator
    Ki, Taekyung
    Jeong, Sangkwon
    CRYOGENICS, 2012, 52 (10) : 518 - 522