Evaluation of volatile eluents and electrolytes for high-performance liquid chromatography-electrospray ionization mass spectrometry and capillary electrophoresis-electrospray ionization mass spectrometry of proteins - II. Capillary electrophoresis

被引:63
|
作者
Huber, CG [1 ]
Premstaller, A [1 ]
Kleindienst, G [1 ]
机构
[1] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
基金
奥地利科学基金会;
关键词
buffer composition; capillary electrophoresis-mass spectrometry; electrospray ionization; polystyrene coating; coating; capillary columns; peptides; proteins;
D O I
10.1016/S0021-9673(99)00533-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peptides and proteins were separated by capillary electrophoresis (CE) in fused-silica capillaries coated with an irreversibly adsorbed monolayer of derivatized polystyrene nanoparticles. Whereas phosphate buffer, pH 3.10, enabled the highly efficient separation of basic proteins with plate counts up to 1 400 000 m(-1), volatile buffer components such as formic acid or acetic acid titrated with ammonia to the desired pH had to be used for the direct coupling of CE with electrospray ionization mass spectrometry (ESI-MS). Compared to 40 mM phosphoric acid-sodium hydroxide, pH 3.10, a background electrolyte containing 125 mM formic acid-ammonia, pH 4.00, was shown to yield equivalent separation efficiency. Investigation of the influence of buffered electrolytes on the ESI-MS signal of lysozyme at pH 2.70-4.00 showed that the charge state distribution shifted to lower charge states at higher pH with a concomitant five-fold decrease in signal intensity of the most abundant signal. The presence of trifluoroacetic acid in the background electrolyte greatly increased the level of baseline noise and completely inhibited the observation of any mass signals related to proteins. Full scan spectra could be acquired from 50-500 fmol amounts of proteins during coupled CE-ESI-NIS utilizing 100-125 mM formic acid-ammonia, pH 3.10. However, compared to UV detection, considerable band broadening is observed with ESI-MS detection which is mainly attributed to column overloading, band spreading in the interface, and scanning data acquisition. Finally, the major whey proteins beta-lactoglobulin A, beta-lactoglobulin B, and alpha-lactalbumin were identified in a whey drink by comparison of molecular masses determined by CE-ESI-MS to molecular masses calculated from the amino acid sequence. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 50 条
  • [11] Analysis of metal species by using electrospray ionization mass spectrometry and capillary electrophoresis electrospray ionization mass spectrometry
    Schramel, O
    Michalke, B
    Kettrup, A
    JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) : 231 - 242
  • [12] CAPILLARY ELECTROPHORESIS-ELECTROSPRAY MASS-SPECTROMETRY FOR RECOMBINANT PROTEINS
    TSUJI, K
    BACZYNSKYJ, L
    BRONSON, GE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 8 - ANYL
  • [13] Characterizing biomolecules by electrospray ionization mass spectrometry coupled to liquid chromatography and capillary electrophoresis
    Hutton, T
    Major, HJ
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1995, 23 (04) : 924 - 927
  • [14] A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides
    Ullsten, S
    Zuberovic, A
    Wetterhall, M
    Hardenborg, E
    Markides, KE
    Bergquist, J
    ELECTROPHORESIS, 2004, 25 (13) : 2090 - 2099
  • [15] Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry as an Alternative Proteomics Platform to Ultraperformance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry for Samples of Intermediate Complexity
    Li, Yihan
    Champion, Matthew M.
    Sun, Liangliang
    Champion, Patricia A. DiGiuseppe
    Wojcik, Roza
    Dovichi, Norman J.
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1617 - 1622
  • [16] A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tseng, MC
    Chen, YR
    Her, GR
    ELECTROPHORESIS, 2004, 25 (13) : 2084 - 2089
  • [17] Advantages of pressurization in capillary electrophoresis/electrospray ionization mass spectrometry
    Hau, J
    Roberts, M
    ANALYTICAL CHEMISTRY, 1999, 71 (18) : 3977 - 3984
  • [18] Determination of isoflavones by capillary electrophoresis electrospray ionization mass spectrometry
    Aramendia, MA
    Borau, V
    Garcia, I
    Jimenez, C
    Lafont, F
    Marinas, JM
    Porras, A
    Urbano, FJ
    JOURNAL OF MASS SPECTROMETRY, 1995, : S153 - S157
  • [19] Determination of isoflavones by capillary electrophoresis/electrospray ionization mass spectrometry
    Aramendia, M.A.
    Borau, V.
    Garcia, I.
    Jimenez, C.
    Lafont, F.
    Marinas, M.
    Porras, A.
    Urbano, F.J.
    Journal of Mass Spectrometry, 1995, (Special):
  • [20] Evaluation of the electrophoretic behaviour of opioid peptides -: Separation by capillary electrophoresis-electrospray ionization mass spectrometry
    Sanz-Nebot, Victoria
    Benavente, Fernando
    Hernandez, Elena
    Barbosa, Jose
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 68 - 76