Dynamic CT of solitary pulmonary nodules: comparison of contrast medium distribution characteristic of malignant and benign lesions

被引:15
|
作者
Ye, X. -D. [1 ,2 ]
Ye, J. -D. [1 ]
Yuan, Z. [3 ,4 ]
Li, W. -T. [3 ]
Xiao, X. -S. [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Radiol, Shanghai Chest Hosp, Shanghai 200030, Peoples R China
[2] Second Mil Med Univ, Dept Radiol, Changzheng Hosp, Shanghai 200003, Peoples R China
[3] Fudan Univ, Dept Radiol, Shanghai Canc Ctr, Shanghai 200032, Peoples R China
[4] Nanjing Univ, Dept Radiol, Nanjing Jinling Hosp, Clin Sch Med Coll, Nanjing 210002, Jiangsu, Peoples R China
来源
CLINICAL & TRANSLATIONAL ONCOLOGY | 2014年 / 16卷 / 01期
关键词
Diagnosis; Dynamic CT; Lung cancer; Nodules; Washout; MULTIDETECTOR ROW CT; ORGANIZING PNEUMONIA; WASHOUT CHARACTERISTICS; ADRENAL MASSES; POTENTIAL ROLE; LUNG-CANCER; ENHANCED CT; FEATURES; PET; TOMOGRAPHY;
D O I
10.1007/s12094-013-1039-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To prospectively assess the role of the dynamic contrast-enhanced CT enhancement characteristics in distinguishing malignant form of benign solitary pulmonary nodules. The study included 87 patients (59 men, 28 women; median age, 59 years) with 87 solitary pulmonary nodules. In all cases, dynamic CT images were obtained before and 20, 30, 45, 60, 75, 90, 120 s, 3, 5, 9, 12, 15 and 20 min after injection of contrast medium. Peak enhancement attenuation value, net enhancement attenuation value, the slope of enhancement, enhancement ratio, outflow of contrast medium (washout), washout ratio and the slope of washout ratio were assessed. Statistical analyses were performed with the Mann-Whitney test, chi(2) test, and receiver-operating characteristic curves. There were 52 malignant and 35 benign nodules. There were no significant differences in net enhancement value, enhancement ratio and the slope of enhancement ratio between malignant and benign nodules (P > 0.05). Malignant nodules showed smaller outflow of contrast medium than did benign nodules. With 12.4HU or lower washout as a cutoff value, the sensitivity and specificity for malignancy were 52.5 and 65.0 %, respectively. With 18.9 % or lower washout ratio as a cutoff value, sensitivity and specificity for malignancy were 60.0 and 75.0 %, respectively. With 0.0180 %/s or lower slope of washout ratio as a cutoff value, sensitivity and specificity for malignancy were 60.0 and 80.0 %, respectively. Dynamic contrast-enhanced CT is helpful in differentiating malignant from benign solitary pulmonary nodules. Smaller washout of contrast enhancement is a predictor that a lesion is malignant.
引用
下载
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [41] Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest images
    Aoyama, M
    Li, Q
    Katsuragawa, S
    MacMahon, H
    Doi, K
    MEDICAL PHYSICS, 2002, 29 (05) : 701 - 708
  • [42] The value of BAL fluid LDH level in differentiating benign from malignant solitary pulmonary nodules
    Ali Emad
    Vahid Emad
    Journal of Cancer Research and Clinical Oncology, 2008, 134 : 489 - 493
  • [43] The Value of LDH Level of BAL Fluid in Differentiating Benign from Malignant Solitary Pulmonary Nodules
    Emad, A.
    Jannati, M.
    Amooee, S.
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2007, 32 (03) : 137 - 142
  • [44] Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest radiographs
    Aoyama, M
    Li, Q
    Abe, H
    Katsuragawa, S
    MacMahon, HM
    Doi, K
    RADIOLOGY, 2001, 221 : 545 - 546
  • [45] The value of BAL fluid LDH level in differentiating benign from malignant solitary pulmonary nodules
    Emad, Ali
    Emad, Vahid
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2008, 134 (04) : 489 - 493
  • [46] PATTERN OF CONTRAST ENHANCEMENT OF PULMONARY NODULES - EVALUATION WITH INCREMENTAL DYNAMIC CT
    MURATA, K
    TAKAHASHI, M
    MORI, M
    SHIMOYAMA, K
    MORITA, R
    RADIOLOGY, 1992, 185 : 267 - 267
  • [47] Value of the texture feature for solitary pulmonary nodules and mass lesions based on PET/CT
    Wang, Changmei
    Guan, Yihui
    Zuo, Chuantao
    Hua, Fengchun
    Chen, Limin
    Zhang, Wenqiang
    Pan, Yan
    Yuan, Yongsheng
    Zhou, Yuan
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [48] Dual time-point FDG PET/CT for differentiating benign from malignant solitary pulmonary nodules in a TB endemic area
    Sathekge, Mike Machaba
    Maes, Alex
    Pottel, Hans
    Stoltz, Anton
    van de Wiele, Christophe
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2010, 100 (09): : 598 - 601
  • [49] Distinguishing benign from malignant pulmonary nodules with helical chest CT in children with malignant solid tumors
    McCarville, MB
    Lederman, HM
    Santana, VM
    Daw, NC
    Shochat, SJ
    Li, CS
    Kaufman, RA
    RADIOLOGY, 2006, 239 (02) : 514 - 520
  • [50] Differential Diagnosis of Benign and Malignant Pulmonary Nodules in CT Images Based on Multitask Learning
    Song, Guanghui
    Dai, Qi
    Nie, Yan
    Chen, Genlang
    CURRENT MEDICAL IMAGING, 2024, 20