In vivo real-time monitoring system of electroporation mediated control of transdermal and topical drug delivery

被引:62
|
作者
Blagus, Tanja [1 ]
Markelc, Bostjan [1 ]
Cemazar, Maja [1 ,2 ]
Kosjek, Tina [3 ]
Preat, Veronique [4 ]
Miklavcic, Damijan [5 ]
Sersa, Gregor [1 ]
机构
[1] Inst Oncol Ljubljana, Dept Expt Oncol, SI-1000 Ljubljana, Slovenia
[2] Univ Primorska, Fac Hlth Sci, SI-6310 Izola, Slovenia
[3] Jozef Stefan Inst, Dept Environm Sci, SI-1000 Ljubljana, Slovenia
[4] Catholic Univ Louvain, Louvain Drug Res Inst, B-1200 Brussels, Belgium
[5] Univ Ljubljana, Fac Elect Engn, SI-1000 Ljubljana, Slovenia
关键词
Electroporation; Transdermal drug delivery; Topical drug delivery; Multi-array electrodes; Monitoring system; Controlled delivery; SKIN ELECTROPORATION; PLASMID DNA; GENE ELECTROTRANSFER; PHYSICAL ENHANCER; INSULIN DELIVERY; ELECTRIC PULSES; VOLTAGE PULSE; EX-VIVO; THERAPY; ELECTROCHEMOTHERAPY;
D O I
10.1016/j.jconrel.2013.09.030
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electroporation (EP) is a physical method for the delivery of molecules into cells and tissues, including the skin. In this study, in order to control the degree of transdermal and topical drug delivery, EP at different amplitudes of electric pulses was evaluated. A new in vivo real-time monitoring system based on fluorescently labeled molecules was developed, for the quantification of transdermal and topical drug delivery. EP of the mouse skin was performed with new non-invasive multi-array electrodes, delivering different amplitudes of electric pulses ranging from 70 to 570 V, between the electrode pin pairs. Patches, soaked with 4 kDa fluorescein-isothiocyanate labeled dextran (FD), doxorubicin (DOX) or fentanyl (FEN), were applied to the skin before and after EP. The new monitoring system was developed based on the delivery of FD to and through the skin. FD relative quantity was determined with fluorescence microscopy imaging, in the treated region of the skin for topical delivery and in a segment of the mouse tail for transdermal delivery. The application of electric pulses for FD delivery resulted in enhanced transdermal delivery. Depending on the amplitude of electric pulses, it increased up to the amplitude of 360 V, and decreased at higher amplitudes (460 and 570 V). Topical delivery steadily enhanced with increasing the amplitude of the delivered electric pulses, being even higher than after tape stripping used as a positive control. The non-invasive monitoring of the delivery of DOX, a fluorescent chemotherapeutic drug, qualitatively and quantitatively confirmed the effects of EP at 360 and 570 V pulse amplitudes on topical and transdermal drug delivery. Delivery of FEN at 360 and 570 V pulse amplitudes verified the observed effects as obtained with FD and DOX, by the measured physiological responses of the mice as well as FEN plasma concentration. This study demonstrates that with the newly developed non-invasive multi-array electrodes and with the varying electric pulse amplitude, the amount of topical and transdermal drug delivery to the skin can be controlled. Furthermore, the newly developed monitoring system provides a tool for rapid real-time determination of both, transdermal and topical delivery, when the delivered molecule is fluorescent. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:862 / 871
页数:10
相关论文
共 50 条
  • [21] Real-time monitoring of drug release
    Weinstain, Roy
    Segal, Ehud
    Satchi-Fainaro, Ronit
    Shabat, Doron
    CHEMICAL COMMUNICATIONS, 2010, 46 (04) : 553 - 555
  • [22] Monitoring drug levels in real-time
    Parks, Lisa
    BIOANALYSIS, 2014, 6 (08) : 1046 - 1046
  • [23] Real-time monitoring system
    不详
    ANTI-CORROSION METHODS AND MATERIALS, 1997, 44 (02) : 137 - 137
  • [24] Recruitment of endocytosis in sonopermeabilization-mediated drug delivery: a real-time study
    Derieppe, Marc
    Rojek, Katarzyna
    Escoffre, Jean-Michel
    de Senneville, Baudouin Denis
    Moonen, Chrit
    Bos, Clemens
    PHYSICAL BIOLOGY, 2015, 12 (04)
  • [25] Multi-wavelength pulse plethysmography for real-time drug delivery monitoring
    Adhikari, Pratik
    Magana, Isidro B.
    O'Neal, D. Patrick
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
  • [26] Development of Sonophoresis Mediated Transdermal Drug Delivery System for Propranolol
    Guo, Lei
    Wang, Pei-Pei
    Li, Qian-Qian
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (09): : 2041 - 2049
  • [27] Real-Time Verification of VMAT Delivery by An Automated Beam Monitoring System
    Farrokhkish, M.
    Islam, M.
    Heaton, R.
    Norrlinger, B.
    Jaffray, D.
    MEDICAL PHYSICS, 2017, 44 (06) : 2879 - 2879
  • [28] A microsensing system for the in vivo real-time detection of local drug kinetics
    Ogata, Genki
    Ishii, Yuya
    Asai, Kai
    Sano, Yamato
    Nin, Fumiaki
    Yoshida, Takamasa
    Higuchi, Taiga
    Sawamura, Seishiro
    Ota, Takeru
    Hori, Karin
    Maeda, Kazuya
    Komune, Shizuo
    Doi, Katsumi
    Takai, Madoka
    Findlay, Ian
    Kusuhara, Hiroyuki
    Einaga, Yasuaki
    Hibino, Hiroshi
    NATURE BIOMEDICAL ENGINEERING, 2017, 1 (08): : 654 - 666
  • [29] A microsensing system for the in vivo real-time detection of local drug kinetics
    Genki Ogata
    Yuya Ishii
    Kai Asai
    Yamato Sano
    Fumiaki Nin
    Takamasa Yoshida
    Taiga Higuchi
    Seishiro Sawamura
    Takeru Ota
    Karin Hori
    Kazuya Maeda
    Shizuo Komune
    Katsumi Doi
    Madoka Takai
    Ian Findlay
    Hiroyuki Kusuhara
    Yasuaki Einaga
    Hiroshi Hibino
    Nature Biomedical Engineering, 2017, 1 : 654 - 666
  • [30] Online Real-Time Water Quality Monitoring and Control System
    Duffy, Paul
    Woods, Gerry
    Walsh, James
    Kane, Michael
    IMCIC 2010: INTERNATIONAL MULTI-CONFERENCE ON COMPLEXITY, INFORMATICS AND CYBERNETICS, VOL II, 2010, : 318 - 323