Prospective, multicenter experience with the Ventana Fenestrated System for juxtarenal and pararenal aortic aneurysm endovascular repair

被引:41
|
作者
Quinones-Baldrich, William J. [1 ]
Holden, Andrew [2 ]
Mertens, Renato [3 ]
Thompson, Matt M. [4 ]
Sawchuk, Alan P. [5 ]
Becquemin, Jean-Pierre [6 ]
Eagleton, Matthew [7 ]
Clair, Daniel G. [7 ]
机构
[1] Univ Calif Los Angeles, Med Ctr, Dept Surg, Los Angeles, CA 90025 USA
[2] Auckland City Hosp, Dept Surg, Auckland, New Zealand
[3] Pontificia Univ Catolica Chile, Dept Surg, Santiago, Chile
[4] St Georges Inst, Dept Surg, London, England
[5] Indiana Univ, Dept Surg, Indianapolis, IN 46204 USA
[6] Hop Henri Mondor, Dept Surg, Paris, France
[7] Cleveland Clin Fdn, Dept Surg, Cleveland, OH 44195 USA
关键词
ENDOGRAFTS; OUTCOMES; GRAFTS; OPTION;
D O I
10.1016/j.jvs.2012.12.065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study assessed preliminary results of the Ventana Fenestrated System (Endologix, Irvine, Calif) as an off-the-shelf integrated device for juxtarenal aortic aneurysm (JAA) or pararenal aortic aneurysm (PAA) endovascular repair. Methods: From November 2010 to April 2012, seven centers enrolled 31 patients with JAAs or PAAs in an international clinical trial of the Ventana Fenestrated System. Clinical and laboratory evaluations were done predischarge and at 1 month, with continuing follow-up through 5 years. Core laboratory computed tomography imaging assessments were performed at 1 month and at each subsequent follow-up. Results: Patients (mean age, 73 years; 90% male) presented with mean aneurysm sac diameter of 6.0 cm. One patient with a short, reversed tapered infra-superior mesenteric artery (SMA) neck was enrolled under a protocol waiver. Among the 31 patients, one of five Ventana devicemodels was used to preservemain renal arteries, the SMA, and celiac arteries; 20 patients (65%) received the same Ventana device (aligned fenestrations, 28-mm diameter). Median fluoroscopy and procedure times were 49 and 197 minutes, respectively; median hospital length of stay was 3.0 days. The 1-month clinical success rate was 94% (29 of 31), with no perioperative mortality. One intervention on day 26 was done to resolve limb kink/occlusion. A type IA endoleak and renal occlusion secondary to procedural device damage led to a reintervention on day 52 and dialysis at 5 months. During follow-up to 23 months, three non-aneurysm-related deaths occurred. No aneurysm rupture or conversion to open repair has occurred. One late migration with endoleak and covered renal stent fracture/occlusion occurred at 8 months in the patient with a short, reverse tapered infra-SMA neck performed under a protocol waiver, which was managed successfully with bilateral renal bypasses and endovascular repair of the endoleak. Another patient underwent late endovascular interventions to resolve bilateral renal stenosis. Conclusions: The multicenter experience of the Ventana Fenestrated System supports its safety and early-term to midterm effectiveness for the endovascular repair of JAAs and PAAs. This off-the-shelf integrated system permits endovascular treatment of JAAs or PAAs; however, further expanded clinical experience and longer-term follow-up are needed to more fully assess this device system.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Monocentric Evaluation of Chimney Versus Fenestrated Endovascular Aortic Repair for Juxtarenal Abdominal Aortic Aneurysm
    Caradu, Caroline
    Morin, Julien
    Poirier, Mathieu
    Midy, Dominique
    Ducasse, Eric
    ANNALS OF VASCULAR SURGERY, 2017, 40 : 28 - 38
  • [22] Fenestrated endovascular aortic repair to eliminate a juxtarenal abdominal aortic aneurysm with concomitant horseshoe kidney
    Ali, Almahdi
    Hirzallah, Muhannad
    Langer, Stephan
    GEFASSCHIRURGIE, 2023, 28 (05): : 385 - 389
  • [23] Endovascular repair of abdominal aortic aneurysm using a pararenal fenestrated stent-graft
    Faruqi, RM
    Chuter, TAM
    Reilly, LM
    Sawhney, R
    Wall, S
    Canto, C
    Messina, LM
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (04): : 354 - 358
  • [24] Fenestrated endovascular repair for juxtarenal aortic pathology DISCUSSION
    Dosluoglu, Hasan
    Kristmundsson, Thorarinn
    Gloviczki, Peter
    Resch, Timothy
    Lanziotti, Luiz
    Chuter, Timothy
    JOURNAL OF VASCULAR SURGERY, 2009, 49 (03) : 574 - 575
  • [25] Experience With Fenestrated Endovascular Repair of Juxtarenal Abdominal Aortic Aneurysms at a Single Center
    Hu, Zhongzhou
    Li, Yue
    Peng, Ran
    Liu, Jie
    Zhang, Tao
    Guo, Wei
    MEDICINE, 2016, 95 (10)
  • [26] Clinical experience with a customized fenestrated endograft for juxtarenal abdominal aortic aneurysm repair
    Uflacker, Renan
    Robison, Jacob D.
    Schonholz, Claudio
    Ivancev, Krassi
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (12) : 1935 - 1942
  • [27] Effects of Iliac Tortuosity Index on Fenestrated Endovascular Aortic Aneurysm Repair for Pararenal and Thoracoabdominal Aortic Aneurysms
    Jordano, Lia
    Robinson, Emilie C.
    Mirza, Aleem
    Skeik, Nedaa
    Stanberry, Larissa
    Manunga, Jesse
    JOURNAL OF ENDOVASCULAR THERAPY, 2025, 32 (02) : 382 - 388
  • [28] Open repair versus fenestrated endovascular aneurysm repair of juxtarenal aneurysms
    Rao, Rohini
    Lane, Tristan R. A.
    Franklin, Ian J.
    Davies, Alun H.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 242 - U591
  • [29] Significant aortic neck dilation occurs after repair of juxtarenal aneurysms with fenestrated endovascular aneurysm repair
    Zettervall, Sara L.
    Dansey, Kirsten
    Kline, Brenda
    Singh, Niten
    Starnes, Benjamin W.
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (04) : 1090 - +
  • [30] Endovascular repair of complex Juxtarenal aortic aneurysm using a combined fenestrated endograft and chimney technique
    Fanari, Zaher
    Goswami, Nilesh J.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (05) : 532 - 535