Surgical reduction of symptomatic, circumferential, filtering blebs

被引:12
|
作者
Anis, Sarah
Ritch, Robert
Shihadeh, Wisam
Liebmann, Jeffrey
机构
[1] New York Eye & Ear Infirm, Glaucoma Serv, Dept Ophthalmol, New York, NY 10003 USA
[2] New York Med Coll, Valhalla, NY 10595 USA
[3] Manhattan Eye Ear & Throat Hosp, New York, NY 10021 USA
[4] NYU Med Ctr, New York, NY 10016 USA
关键词
D O I
10.1001/archopht.124.6.890
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We describe methods and outcomes of surgical reduction of symptomatic, circumferential, filtering blebs after trabeculectomy with antifibrotic agents. The medical records of 15 eyes of 14 patients with symptomatic, circumferential blebs who underwent surgical bleb reduction for bleb dysesthesia under topical anesthesia were reviewed. Each bleb was incised segmentally and the cut edges of the conjunctiva and Tenon capsule were sutured to the underlying sclera. Outcome measures included symptomatic relief, retention of bleb function, and intraocular pressure maintenance. Fourteen eyes had successful reduction of bleb size, symptomatic relief, and cosmetically acceptable appearance. One eye continued to have dysesthesia and 1 had a transient bleb leak that resolved spontaneously. Surgical reduction of circumferential, symptomatic, filtering blebs is a safe and effective technique to reduce bleb dysesthesia and improve cosmesis without loss of bleb function.
引用
收藏
页码:890 / 894
页数:5
相关论文
共 50 条
  • [31] Sutureless revision of overhanging filtering blebs
    Anis, Sarah
    Ritch, Robert
    Shihadeh, Wisam
    Liebmann, Jeffrey
    ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (09) : 1317 - 1320
  • [32] Functional proteomics of failed filtering blebs
    Kanamoto, Takashi
    Souchelnytskyi, Nazariy
    Kiuchi, Yoshiaki
    MOLECULAR VISION, 2009, 15 (291-92): : 2762 - 2770
  • [33] LENSECTOMY AND VITRECTOMY IN THE PRESENCE OF FILTERING BLEBS
    PEYMAN, GA
    CARNEY, MD
    HIGGINBOTHAM, EJ
    INTERNATIONAL OPHTHALMOLOGY, 1987, 10 (03) : 143 - 147
  • [34] Ultrasound biomicroscopic evaluation of filtering blebs
    Avitabile, T
    Uva, MG
    Russo, V
    Ott, JP
    Paulick, B
    Reibaldi, A
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (02) : 101 - 105
  • [35] Spontaneous inferior subconjunctival haemorrhages in association with circumferential drainage blebs
    A P Wells
    J Marks
    P T Khaw
    Eye, 2005, 19 : 269 - 272
  • [36] Spontaneous inferior subconjunctival haemorrhages in association with circumferential drainage blebs
    Wells, AP
    Marks, J
    Khaw, PT
    EYE, 2005, 19 (03) : 269 - 272
  • [37] Remodeling filtering blebs with the Neodymium:YAG laser
    Lynch, MG
    Roesch, M
    Brown, RH
    OPHTHALMOLOGY, 1996, 103 (10) : 1700 - 1705
  • [38] SURGICAL REPAIR OF LEAKING BLEBS
    GALIN, MA
    HUNG, PT
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1977, 83 (03) : 328 - &
  • [39] Fitting contact lenses in eyes with filtering blebs
    Grohe, RM
    Wyse, TB
    JOURNAL OF GLAUCOMA, 1998, 7 (06) : 439 - 445
  • [40] REPAIR OF FILTERING BLEBS FOLLOWING CATARACT SURGERY
    CHRISTENSEN, RE
    RUNDLE, HL
    ARCHIVES OF OPHTHALMOLOGY, 1970, 84 (01) : 8 - +