Analytical ultracentrifuge for the characterization of detergent in solution

被引:22
|
作者
Salvay, Andres G. [1 ,2 ]
Ebel, Christine [1 ]
机构
[1] CNRS, Inst Biol Struct, Lab Mol Biophys, CEA,UMR 5075,UJF, 41 rue Jules Horowitz, F-38027 Grenoble 01, France
[2] Univ Nacl La Plata, Inst Fis Liquidos & Sist Biol, CC 565, RA-1900 La Plata, Argentina
来源
ANALYTICAL ULTRACENTRIFUGATION VIII | 2006年 / 131卷
关键词
analytical ultracentrifugation; detergents; membrane; proteins;
D O I
10.1007/2882_006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have characterized the hydrodynamic behaviour in H2O and D2O of two detergents, dodecyl-beta-D-maltoside (DDM) and octaethylene glycol monododecyl ether (C12E8), by analysing sedimentation velocity profiles obtained with interference optics in terms of continuous particle distribution and non-interacting species. The analysis in H2O provides values for the sedimentation and diffusion coefficients that give aggregation numbers of 130 and 115 for DDM and C12E8, respectively, close to that given in the literature. The analysis of the number of interference fringes as a function of detergent concentration gave values for the critical micelle concentration and refractive index increments that are also in good agreement with published values. The values of the partial specific volumes of DDM and C12E8, obtained by sedimentation in H2O and D2O - where C12E8 floats - are identical to those obtained from density measurements. These results indicate that sedimentation velocity has good potential for proper characterisation of detergent-solubilized proteins.
引用
收藏
页码:74 / +
页数:3
相关论文
共 50 条
  • [31] LASER LIGHT-SOURCE FOR ANALYTICAL ULTRACENTRIFUGE
    WILLIAMS, RC
    ANALYTICAL BIOCHEMISTRY, 1972, 48 (01) : 164 - &
  • [32] DYNAMIC ERRORS OF PHOTOELECTRICAL SCANNER OF AN ANALYTICAL ULTRACENTRIFUGE
    LOTTS, YA
    MARGOLIN, AK
    SAMBURSKII, AI
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA A, 1975, 17 (05): : 1181 - 1186
  • [33] A light intensity measurement system for the analytical ultracentrifuge
    Laue, Thomas M.
    Austin, Joseph B.
    Rau, David A.
    ANALYTICAL ULTRACENTRIFUGATION VIII, 2006, 131 : 1 - +
  • [34] 2 EXPERIMENTS IN ONE RUN WITH THE ANALYTICAL ULTRACENTRIFUGE
    BON, WF
    RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS-JOURNAL OF THE ROYAL NETHERLANDS CHEMICAL SOCIETY, 1958, 77 (11): : 1135 - 1137
  • [35] Analytical Ultracentrifuge and Its Utilization in Biochemical Laboratory
    Vanek, Ondrej
    Bezouska, Karel
    CHEMICKE LISTY, 2010, 104 (12): : 1155 - 1162
  • [36] Analytical ultracentrifuge study of micellization of surfactant mixtures
    Lu, Shaohua
    Somasundaran, P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [37] BAND-FORMING CENTERPIECES FOR ANALYTICAL ULTRACENTRIFUGE
    VINOGRAD, J
    RADLOFF, R
    BRUNER, R
    BIOPOLYMERS, 1965, 3 (04) : 481 - &
  • [38] Challenges for the modern analytical ultracentrifuge analysis of polysaccharides
    Harding, SE
    CARBOHYDRATE RESEARCH, 2005, 340 (05) : 811 - 826
  • [39] The analytical ultracentrifuge as a probe for interface transport phenomena
    Harding, SE
    Tombs, MP
    BIOTECHNOLOGY & GENETIC ENGINEERING REVIEWS, VOL 19, 2002, 19 : 55 - 69
  • [40] Prototype fluorimeter for the XLA/XLI analytical ultracentrifuge
    Laue, TM
    Anderson, AL
    Weber, BJ
    ULTRASENSITIVE BIOCHEMICAL DIAGNOSTICS II, PROCEEDINGS OF, 1997, 2985 : 196 - 204