IDENTIFICATION OF COMPENSATORY ARTERIAL DYNAMICS IN SWINE USING A NON-INVASIVE SENSOR FOR LOCAL VASCULAR RESISTANCE

被引:0
|
作者
Wang, Lu [1 ]
Ansari, Sardar [1 ]
Ward, Kevin R. [1 ]
Najarian, Kayvan [1 ]
Oldham, Kenn R. [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
来源
PROCEEDINGS OF THE ASME 11TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2018, VOL 1 | 2018年
基金
美国国家科学基金会;
关键词
TONE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Autoregulatory dynamics of the cardiovascular system play an important role in maintaining oxygenated blood transportation throughout the human body. In this work, a feedback dynamics model of the cardiovascular system with respect to heartrate and peripheral vascular resistance effects on longer-term blood pressure changes in the systemic circulation is presented. The model is identified from data taken from a swine test subject, instrumented in part with a wearable, non-invasive sensor for estimating peripheral arterial radius. Comparative simulations for the open and close loop model highlight significantly changed hemodynamics after hemorrhage.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Non-Invasive Respiration Monitoring Sensor Using UWB-IR
    Higashikaturagi, Kenji
    Nakahata, Youichiro
    Matsunami, Isamu
    Kajiwara, Akihiro
    2008 IEEE INTERNATIONAL CONFERENCE ON ULTRA-WIDEBAND, VOL 1, PROCEEDINGS, 2008, 1 : 101 - 104
  • [42] Photoacoustic Sensor Using Silicon Piezoresistor for Non-Invasive Measurement of Glucose
    Noda K.
    Tsukagoshi T.
    Shimoyama I.
    IEEJ Transactions on Sensors and Micromachines, 2023, 143 (07) : 171 - 175
  • [43] Non-invasive cell type selective in vivo monitoring of insulin resistance dynamics
    Paschen, Meike
    Moede, Tilo
    Leibiger, Barbara
    Jacob, Stefan
    Bryzgalova, Galyna
    Leibiger, Ingo B.
    Berggren, Per-Olof
    SCIENTIFIC REPORTS, 2016, 6
  • [44] Hemoglobin Estimation in Predonation Screening Using a Non-invasive Hemoglobin Sensor
    Kim, M.
    Kim, M.
    Hwang, Y.
    Kim, H.
    TRANSFUSION, 2012, 52 : 93A - 93A
  • [45] NON-INVASIVE SURVEY OF OLD PAINTINGS USING VNIR HYPERSPECTRAL SENSOR
    Matouskova, E.
    Pavelka, K.
    Svadlenkova, Z.
    XXIV INTERNATIONAL CIPA SYMPOSIUM, 2013, 40-5-W2 : 425 - 429
  • [46] Non-invasive measurement of spoilage of packed fish using halochromic sensor
    Devarayan, Kesavan
    Palanisamy, Yazhiniyan
    Mohan, Gangeswar
    Theivasigamani, Anand
    Kandasamy, Sabariswaran
    Sekar, Vimaladevi
    John, Evon Umesh Siluvai
    Sukumaran, Monikandon
    Marimuthu, Ramar
    Anjappan, Hema
    PIGMENT & RESIN TECHNOLOGY, 2025, 54 (03) : 467 - 472
  • [47] Vehicle detection using non-invasive magnetic wireless sensor network
    Liepins, M.
    Severdaks, A.
    2013 21ST TELECOMMUNICATIONS FORUM (TELFOR), 2013, : 601 - 604
  • [48] Non-Invasive Measurement for Cardiac Variations Using a Fiber Optic Sensor
    Lyu, Weimin
    Xu, Wei
    Yang, Fangang
    Chen, Shuyang
    Tan, Fengze
    Yu, Changyuan
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2021, 33 (18) : 990 - 993
  • [49] Non-invasive cell type selective in vivo monitoring of insulin resistance dynamics
    Meike Paschen
    Tilo Moede
    Barbara Leibiger
    Stefan Jacob
    Galyna Bryzgalova
    Ingo B. Leibiger
    Per-Olof Berggren
    Scientific Reports, 6
  • [50] Continuous non-invasive arterial pressure measurement: Evaluation of CNAP™ device during vascular surgery
    Biais, M.
    Vidil, L.
    Roullet, S.
    Masson, F.
    Quinart, A.
    Revel, P.
    Sztark, F.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2010, 29 (7-8): : 530 - 535