Activity regimes for 82Rb cardiac PET: Effects on absolute MBF and MPI

被引:5
|
作者
Hoff, Camilla M. [1 ]
Sorensen, Jens [2 ,3 ]
Christensen, Nana L. [1 ]
Bouchelouche, Kirsten [1 ,2 ]
Tolbod, Lars [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Nucl Med & PET, Aarhus, Denmark
[2] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[3] Uppsala Univ, Dept Surg Sci, Radiol, Uppsala, Sweden
关键词
PET; MPI; myocardial blood flow; instrumentation; image analysis; MYOCARDIAL BLOOD-FLOW; RB-82; PET; PERFUSION; QUANTIFICATION; ACCURACY;
D O I
10.1007/s12350-020-02266-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Selection of optimal tracer activity for 82Rb PET is based on a trade-off between necessary count-statistics in the late static phase and detector saturation in the early blood-pool phase. Administered tracer activity recommended in prescribing information differs substantially from recommendations in current literature. The present study examines the effect on both absolute myocardial blood flow (MBF), myocardial flow reserve (MFR) and relative myocardial perfusion imaging (MPI) of reducing dose. Methods Forty patients were scanned twice on a PMT-based PET/CT (GE D690): At recommended activity (1110 MBq) and at either 740 or 370 MBq. MBF, MFR, total perfusion deficit (TPD) and ejection fractions (EF) were quantified. Results were compared using linear regression and Bland-Altman plots. Results Linear correlation between MBF at 1110 MBq at either reduced activity had anR(2) > 0.98. A small bias (+/- 5%-9%) was observed with opposite signs for 1110/740 and 1110/370. Limits of agreement for MBF were larger for 1110/370. MFR had a lower linear correlation (R-2 = 0.96), but wide limits of agreement especially for 1110/370. TPD and EF correlated well at 1110/740 (R-2 = 0.96 and 0.99, respectively), but large scatter was observed for 1110/370. Conclusion Reduction of the tracer activity to 740 MBq, significantly reduced dead-time correction factors, while still producing reliable static and gated images. However, despite large dead-time at 1110 MBq, no systematic bias on absolute MBF was observed compared to reduced activities.
引用
收藏
页码:449 / 460
页数:12
相关论文
共 50 条
  • [1] Activity regimes for 82Rb cardiac PET: Effects on absolute MBF and MPI
    Camilla M. Hoff
    Jens Sørensen
    Nana L. Christensen
    Kirsten Bouchelouche
    Lars Tolbod
    Journal of Nuclear Cardiology, 2022, 29 : 449 - 460
  • [2] Comparison of 82Rb PET/CT MPI with cardiac catheterization
    Backhaus, Hans
    Johnson, Carlyn
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [3] Reduced variance of MBF estimates by dynamic 82Rb PET
    Moody, Jonathan
    Ficaro, Edward
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] Improved homogeneity of normal MBF using factor analysis with 82Rb PET
    Klein, Ran
    Yoshinaga, Keiichiro
    Katoh, Chietsugu
    Adler, Andy
    Beanlands, Robert
    Tamaki, Nagara
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [5] Assessment of endothelial dependent coronary vasoreactivity in patients with OSA using MBF quantification with 82Rb cardiac PET
    Dunet, Vincent
    Heinzer, Raphael
    Rey-Bataillard, Vincianne
    Beysard, Nicolas
    Delaloye, Aline
    Jayet, Pierre-Yves
    Lovis, Alban
    Allenbach, Gilles
    Prior, John
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [6] IMPROVED HOMOGENEITY OF NORMAL MBF USING FACTOR-ANALYSIS WITH 82RB PET
    Klein, R.
    Yoshinaga, K.
    Katoh, C.
    Adler, A.
    Beanlands, R. B.
    Tamaki, N.
    DeKemp, R. A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 136D - 136D
  • [7] Quantification of myocardial blood flow (MBF) from 82Rb cardiac PET studies: A comparison study of two automatic
    Dunet, Vincent
    Hatem, Natalie Abi
    El Hakmaoui, Fatima
    Allenbach, Gilles
    Brady, Thomas
    Prior, John
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [8] Pathophysiologic correlates of 82Rb biodistribution in cardiac PET/CT
    Brown, Tracy Lynnette Yarbrough
    Voicu, Corina
    Merrill, Jennifer
    Bengel, Frank M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (03) : 479 - 484
  • [9] Detection of serial changes in absolute myocardial perfusion with 82Rb PET
    deKemp, RA
    Ruddy, TD
    Hewitt, T
    Dalipaj, MM
    Beanlands, RSB
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (08) : 1426 - 1435
  • [10] Pathophysiologic correlates of 82Rb biodistribution in cardiac PET/CT
    Tracy Lynnette Yarbrough Brown
    Corina Voicu
    Jennifer Merrill
    Frank M. Bengel