Sliding hip screw versus the Targon PF nail in the treatment of trochanteric fractures of the hip A RANDOMISED TRIAL OF 600 FRACTURES

被引:83
|
作者
Parker, M. J. [1 ]
Bowers, T. R.
Pryor, G. A. [1 ]
机构
[1] Peterborough & Stamford Hosp NHS Fdn Trust, Peterborough City Hosp, Dept Orthopaed, Peterborough PE3 9GZ, Cambs, England
来源
关键词
INTERTROCHANTERIC FRACTURES; FEMORAL FRACTURES; MOBILITY SCORE; INTRAMEDULLARY; RELIABILITY; FIXATION; FEMUR;
D O I
10.1302/0301-620X.94B3.28406
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In a randomised trial involving 598 patients with 600 trochanteric fractures of the hip, the fractures were treated with either a sliding hip screw (n = 300) or a Targon PF intramedullary nail (n = 300). The mean age of the patients was 82 years (26 to 104). All surviving patients were reviewed at one year with functional outcome assessed by a research nurse blinded to the treatment used. The intramedullary nail was found to have a slightly increased mean operative time (46 minutes (SD 12.3) versus 49 minutes (so 12.7), p < 0.001) and an increased mean radiological screening time (0.3 minutes (SD 0.2) versus 0.5 minutes (SD 0.3), p < 0.001). Operative difficulties were more common with the intramedullary nail. There was no statistically significant difference between implants for wound healing complications (p = 1), or need for post-operative blood transfusion (p = 1), and medical complications were similarly distributed in both groups. There was a tendency to fewer revisions of fixation or conversion to an arthroplasty in the nail group, although the difference was not statistically significant (nine versus three cases, p = 0.14). The extent of shortening, loss of hip flexion, mortality and degree of residual pain were similar in both groups. The recovery of mobility was superior for those treated with the intramedullary nails (p = 0.01 at one year from injury). In summary, both implants produced comparable results but there was a tendency to better return of mobility for those treated with the intramedullary nail.
引用
收藏
页码:391 / 397
页数:7
相关论文
共 50 条
  • [21] Femoral Medialization, Fixation Failures, and Functional Outcome in Trochanteric Hip Fractures Treated With Either a Sliding Hip Screw or an Intramedullary Nail From Within a Randomized Trial
    Bretherton, Christopher P.
    Parker, Martyn J.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (12) : 642 - 646
  • [22] Fixed nail plates versus sliding hip systems for the treatment of trochanteric femoral fractures: a meta analysis of 14 studies
    Chinoy, MA
    Parker, MJ
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (03): : 157 - 163
  • [23] Sliding hip screw versus sliding helical blade for intertrochanteric fractures
    Fang, C.
    Lau, T. W.
    Wong, T. M.
    Lee, H. L.
    Leung, F.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (03): : 398 - 404
  • [24] Critical evaluation: sliding hip screw or Gamma nail for hip fractures? Appraisal of a Cochrane review
    Adie, Sam
    Harris, Ian A.
    [J]. ANZ JOURNAL OF SURGERY, 2009, 79 (11) : 851 - 853
  • [25] Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw
    Madsen, JE
    Naess, L
    Aune, AK
    Alho, A
    Ekeland, A
    Stromsoe, K
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) : 241 - 248
  • [26] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [27] Dynamic hip screw versus proximal femoral nail for treatment of trochanteric hip fractures: an outcome analyses with a minimum 2 years of follow-up
    Orcun Sahin
    Huseyin Demirors
    Rahmican Akgun
    Ihsan Senturk
    Ismail Cengiz Tuncay
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 473 - 480
  • [28] A Comparison of Proximal Femoral Nail Antirotation and Dynamic Hip Screw Devices in Trochanteric Fractures
    Zou, J.
    Xu, Y.
    Yang, H.
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (04) : 1057 - 1064
  • [29] Dynamic hip screw versus proximal femoral nail for treatment of trochanteric hip fractures: an outcome analyses with a minimum 2 years of follow-up
    Sahin, Orcun
    Demirors, Huseyin
    Akgun, Rahmican
    Senturk, Ihsan
    Tuncay, Ismail Cengiz
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (06): : 473 - 480
  • [30] Surgical treatment of intertrochanteric hip fractures with associated femoral neck fractures using a sliding hip screw
    Kyle, RF
    Ellis, TJ
    Templeman, DC
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (01) : 1 - 4