MEASUREMENT OF THE EQUIVALENT INDIVIDUAL DOSES FOR PATIENTS IN ANGIOGRAPHY PROCEDURE AND INTERVENTIONAL RADIOLOGY WITH THERMOLUMINESCENT SYSTEMS

被引:0
|
作者
Adam, Daniela [1 ]
Stochioiu, Ana [2 ]
机构
[1] Bucharest Emergency Univ Hosp, Bucharest, Romania
[2] Horia Hulubei Natl Inst Phys & Nucl Engn, IFIN HH, Magurele, Romania
来源
ROMANIAN JOURNAL OF PHYSICS | 2013年 / 58卷 / 3-4期
关键词
equivalent dose; TLD; DAP;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The aspects of radiation injuries in IR were highlighted and the increasing concern about the high skin dose levels in cardiology and other IR procedures, as it is very important a close monitoring in order to prevent stochastic effects and, in time, deterministic effects. The present study reports on investigations that we have performed to allow the calculation of the individual penetrant radiation dose, Hp(10) in interventional radiology and also the important results in determining the homogeneity of the radiation flux. In order to determine the uniformity of large area beams with a better precision, thermoluminescent matrices of 8 x 12cm size, containing arrays of chips, uniformly distributed in each row and column of the matrix, were used. From the measurements we obtained accurate data of the dose received by patients in different areas of the body. Measurement method using TLD's is net superior to the measurement with Dap-meter. Due to the potential for stochastic and deterministic effects existing in interventional radiology, dosimetry information is required to make the interventionalist aware of the potential for such effects.
引用
收藏
页码:330 / 336
页数:7
相关论文
共 45 条
  • [21] Trauma Hybrid Operating Room (THOR) shortened procedure time in abdominopelvic trauma patients requiring surgery and interventional radiology procedures
    Prichayudh, Supparerk
    Rajruangrabin, Jaratvit
    Sriussadaporn, Suvit
    Pak-art, Rattaplee
    Sriussadaporn, Sukanya
    Kritayakirana, Kritaya
    Samorn, Pasurachate
    Narueponjirakul, Natawat
    Uthaipaisanwong, Apinan
    Aimsupanimitr, Punthita
    Chaisiriprasert, Patcharee
    Kranokpiraksa, Pawanrat
    Chanpen, Nantiskarn
    Pinjaroen, Nutcha
    Ouwongprayoon, Pongsakorn
    Charoenvisal, Ching
    Jantarattana, Trirat
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (02): : 513 - 518
  • [22] Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures
    Cusma, JT
    Bell, MR
    Wondrow, MA
    Taubel, JP
    Holmes, DR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) : 427 - 435
  • [23] The Role of Interventional Radiology and Management of an Angiography Suite in the Treatment of COVID-19 Patients: Single-Center, 2-Year Experience
    Shim, Jongjoon
    Lee, Jae Myeong
    MEDICINA-LITHUANIA, 2023, 59 (02):
  • [24] Estimation of equivalent organ and effective doses to patients undergoing coronary angiography and percutaneous coronary intervention procedures using Monte Carlo simulation
    Ngaile, J. E.
    Msaki, P. K.
    Nyanda, P. B.
    Muhulo, A. P.
    Muhogora, W. E.
    Mvungi, R.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [25] Conversion factors of effective and equivalent organ doses with the air kerma area product in patients undergoing coronary angiography and percutaneous coronary interventions
    Brambilla, M.
    Cannillo, B.
    Matheoud, R.
    Compagnone, G.
    Rognoni, A.
    Bongo, A. S.
    Carriero, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 189 - 196
  • [26] Combined Interventional Radiology Followed by Endoscopic Therapy as a Single Procedure for Patients With Failed Initial Endoscopic Biliary Access: A Single Academic Center Experience
    Tomizawa, Yutaka
    Mccluskey, Kevin
    Santos, Ernesto
    Digiorgio, Jose
    Gelrud, Andres
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 402 - 402
  • [27] Measurement of Pulmonary Circulation Parameters Using Time-Resolved MR Angiography in Patients After Ross Procedure
    Lakoma, Anna
    Tuite, David
    Sheehan, John
    Weale, Peter
    Carr, James C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 912 - 919
  • [28] Randomized study comparing the impact of FFR measurement in patients with intermediate coronary stenoses allocated by angiography to conservative versus interventional treatment SPECTRUM trial
    Figueiredo, G. L.
    Marin, G. B.
    Badran, A. V.
    Novaes, G. C.
    Lemos, D. C.
    Lago, I. M.
    Haddad, J. L.
    Lima-Filho, M. O.
    Lemos-Neto, P. A.
    Marin-Neto, J. A.
    EUROPEAN HEART JOURNAL, 2015, 36 : 1193 - 1193
  • [29] Phase I/II Study of Transjugular Transhepatic Peritoneovenous Venous Shunt, a New Procedure to Manage Refractory Ascites in Cancer Patients: Japan Interventional Radiology in Oncology Study Group 0201
    Arai, Yasuaki
    Inaba, Yoshitaka
    Sone, Miyuki
    Saitoh, Hiroya
    Takeuchi, Yoshito
    Shioyama, Yasukazu
    Nakajima, Yasuo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : W621 - W626
  • [30] INTERCOMPARISON ON THE MEASUREMENT OF THE QUANTITY PERSONAL DOSE EQUIVALENT HP(10) IN PHOTON FIELDS. LINEARITY DEPENDENCE, LOWER LIMIT OF DETECTION AND UNCERTAINTY IN MEASUREMENT OF DOSIMETRY SYSTEMS OF INDIVIDUAL MONITORING SERVICES IN GABON AND GHANA
    Meye, P. Ondo
    Schandorf, C.
    Amoako, J. K.
    Manteaw, P. O.
    Amoatey, E. A.
    Adjei, D. N.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (03) : 250 - 260