MEASUREMENT OF THE EQUIVALENT INDIVIDUAL DOSES FOR PATIENTS IN ANGIOGRAPHY PROCEDURE AND INTERVENTIONAL RADIOLOGY WITH THERMOLUMINESCENT SYSTEMS

被引:0
|
作者
Adam, Daniela [1 ]
Stochioiu, Ana [2 ]
机构
[1] Bucharest Emergency Univ Hosp, Bucharest, Romania
[2] Horia Hulubei Natl Inst Phys & Nucl Engn, IFIN HH, Magurele, Romania
来源
ROMANIAN JOURNAL OF PHYSICS | 2013年 / 58卷 / 3-4期
关键词
equivalent dose; TLD; DAP;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The aspects of radiation injuries in IR were highlighted and the increasing concern about the high skin dose levels in cardiology and other IR procedures, as it is very important a close monitoring in order to prevent stochastic effects and, in time, deterministic effects. The present study reports on investigations that we have performed to allow the calculation of the individual penetrant radiation dose, Hp(10) in interventional radiology and also the important results in determining the homogeneity of the radiation flux. In order to determine the uniformity of large area beams with a better precision, thermoluminescent matrices of 8 x 12cm size, containing arrays of chips, uniformly distributed in each row and column of the matrix, were used. From the measurements we obtained accurate data of the dose received by patients in different areas of the body. Measurement method using TLD's is net superior to the measurement with Dap-meter. Due to the potential for stochastic and deterministic effects existing in interventional radiology, dosimetry information is required to make the interventionalist aware of the potential for such effects.
引用
收藏
页码:330 / 336
页数:7
相关论文
共 45 条
  • [1] Doses to patients in interventional radiology
    Staniszewska, MA
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C437 - C437
  • [2] ASSESSMENT OF LITHIUM BORATE THERMOLUMINESCENT DOSIMETERS FOR MEASUREMENT OF DOSES TO PATIENTS IN DIAGNOSTIC RADIOLOGY
    LANGMEAD, WA
    WALL, BF
    PALMER, KE
    BRITISH JOURNAL OF RADIOLOGY, 1976, 49 (587): : 956 - 962
  • [3] Effective doses in angiography and interventional radiology: calculation of conversion coefficients for angiography of the lower limbs
    Struelens, L
    Vanhavere, F
    Bosmans, H
    Van Loon, R
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926): : 135 - 142
  • [4] Measurement of internal constraints during.an interventional radiology procedure
    Ilic, D.
    Moix, I.
    Lambercy, O.
    Sache, L.
    Bleuler, H.
    Ohta, M.
    Augsburger, L.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2615 - 2618
  • [5] Patient doses in interventional radiology: Accuracy in measurement and proper use of nomenclature
    McParland, BJ
    RADIOLOGY, 1998, 209 (02) : 589 - 590
  • [6] Patient doses in interventional radiology:: Accuracy in measurement and proper use of nomenclature -: response
    Ruiz-Cruces, R
    Pérez-Martínez, M
    RADIOLOGY, 1998, 209 (02) : 590 - 590
  • [7] Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign
    Nikodemova, D.
    Brodecki, M.
    Carinou, E.
    Domienik, J.
    Donadille, L.
    Koukorava, C.
    Krim, S.
    Ruiz-Lopez, N.
    Sans-Merce, M.
    Struelens, L.
    Vanhavere, F.
    Zaknoune, R.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1210 - 1215
  • [8] Patients radiation doses analysis in a contemporary cohort of patients undergoing interventional radiology procedures
    Nogales, J. M.
    Ordiales, J. M.
    Martinez-Naharro, A.
    Yuste-Dominguez, M.
    Sanchez-Giralt, S.
    Lopez-Minguez, J. R.
    Gonzalez-Fernandez, R.
    Martinez-Caceres, G.
    Merchan-Herrera, A.
    Diaz-Cortegana, F.
    EUROPEAN HEART JOURNAL, 2012, 33 : 242 - 242
  • [9] MCNP Simulation of Radiation Doses Distributions in a Water Phantoms Simulating Interventional Radiology Patients
    He, Wenjun
    Mah, Eugene
    Huda, Walter
    Selby, Bayne
    Yao, Hai
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [10] Skin dose measurement for patients using imaging plates in interventional radiology procedures
    Ohuchi, Hiroko
    Satoh, Toshimitsu
    Eguchi, Yoichi
    Kaga, Yuji
    Arai, Takeshi
    Suzuki, Shin-ichi
    Yamadera, Akira
    HEALTH PHYSICS, 2007, 93 (01): : 78 - 86