Correlation between corneal hysteresis, corneal resistance factor, and ocular pulse amplitude in healthy subjects

被引:2
|
作者
Ehongo, A. [1 ]
de Maertelaer, V. [1 ]
Cullus, P. [1 ]
Pourjavan, S. [1 ]
机构
[1] ULB, Hop Erasme, Serv Ophtalmol, B-1070 Brussels, Belgium
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2008年 / 31卷 / 10期
关键词
Corneal hysteresis; corneal resistance factor; ocular pulse amplitude; Pascal dynamic contour tonometer; ocular response analyzer;
D O I
10.1016/S0181-5512(08)74747-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The Ocular Response Analyzer (ORA) measures corneal biomechanical properties: corneal hysteresis (CH) and the corneal resistance factor (CRF). The Pascal Dynamic Contour Tonometer (PDCT) measures the ocular pulse amplitude (OPA), which represents the systolic-diastolic variation in intraocular pressure (IOP). Both ORA(R) and OPA values are lower in glaucoma patients than in normal patients. Our purpose was to assess whether there is a correlation between CH, CRF, and OPA values in healthy subjects. Design and participants: Prospective observational study including 81 eyes of 41 healthy adult volunteers. Patients with ocular eye disease, previous refractive or intraocular surgery, contact lenses, or topical or general medications were excluded. Methods: Patients underwent four ORA, three OPA, and two Goldmann Applanation Tonometry (GAT) measurements. For each device, the mean of all measurements were considered for this study. The statistical analysis by Spearman rank correlations was performed for right (RE), left (LE), and both eyes. The correlation between the two eyes of each subject was taken into account and canonical correlations were calculated using the SAS statistical software to improve the power of the analysis. Results: The mean age was 43.6 +/- 14.6 years. The mean central corneal thickness was 545 +/- 32 mu m for RE, 553 +/- 34 mu m for LE, and 550 +/- 32 mu m for both eyes. The mean IOP(GAT) values for RE, LE, and both eyes were, respectively 14.3 +/- 2.9 mmHg, 14.0 +/- 2.9 mmHg, and 14.2 +/- 2.9 mmHg. Spearman correlations were not statistically significant for separated RE and LE analysis. For both eyes, these correlations were r(S) = 0.210, p = 0.193 for OPA/CH and r(S) = 0.388, p = 0.013 for CPA/CRF. The Spearman correlation was statistically significant for OPA/CRF. This result was confirmed by canonical correlations (p = 0.002) and in addition, CH was statistically correlated to OPA in the latter analysis (p = 0.010). Conclusion: A statistically significant correlation was found between corneal biomechanical property values as measured by ORA(R) and ocular pulse amplitude values as measured by PDCT in healthy subjects.
引用
收藏
页码:999 / 1005
页数:7
相关论文
共 50 条
  • [41] The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis
    Fujishiro, Takashi
    Matsuura, Masato
    Fujino, Yuri
    Murata, Hiroshi
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    [J]. JOURNAL OF GLAUCOMA, 2020, 29 (06) : 479 - 484
  • [42] Lack of Association Between Corneal Hysteresis and Corneal Resistance Factor With Glaucoma Severity in Primary Angle Closure Glaucoma (vol 56, pg 6879, 2015)
    Nongpiur, Monisha E.
    Png, Owen
    Chiew, Jestin W.
    Fan, Kenric R.
    Girard, Michael J. A.
    Wong, Tina
    Goh, David
    Perera, Shamira A.
    Aung, Tin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (03) : 876 - 876
  • [43] Relationship between Corneal Hysteresis and Visual Field Progression in Glaucoma and Ocular Hypertensive Eyes
    Pazos, Marta
    Anton, Alfonso
    Jesus Lopez-Valladares, Maria
    Tinguaro Diaz-Aleman, Valentin
    Fallon, Monica
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [44] Fluctuations of the Ocular Response Analyzer in measuring Corneal Hysteresis of subjects with and without Glaucoma and other Systemic Conditions
    Chandrasekaran, Subhashini
    Uppuluri, Siri
    Sadek, Hadeel
    Lu, Ziyao
    Khouri, Albert S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [45] Corneal Biomechanics Determination in Healthy Myopic Subjects
    Qiu, Kunliang
    Lu, Xuehui
    Zhang, Riping
    Wang, Geng
    Zhang, Mingzhi
    [J]. JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [46] Diurnal Variation of Ocular Hysteresis, Corneal Thickness, and Intraocular Pressure
    Shen, Meixiao
    Wang, Jianhua
    Qu, Jia
    Xu, Suzhong
    Wang, Xiaoxing
    Fang, Haizhen
    Lu, Fan
    [J]. OPTOMETRY AND VISION SCIENCE, 2008, 85 (12) : 1185 - 1192
  • [47] Correlation between central corneal thickness and intraocular pressure in normal subjects
    Renucci, AM
    Romano, AC
    Yoo, SH
    Muallem, M
    Culbertson, WW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U377 - U377
  • [48] Wavelet Representation of the Corneal Pulse for Detecting Ocular Dicrotism
    Melcer, Tomasz
    Danielewska, Monika E.
    Iskander, D. Robert
    [J]. PLOS ONE, 2015, 10 (04):
  • [49] Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
    Figueiredo, Bruno P.
    Cronemberger, Sebastiao
    Kanadani, Fabio N.
    [J]. CLINICAL OPHTHALMOLOGY, 2013, 7 : 1615 - 1621
  • [50] Variation of Corneal Hysteresis in a Population Based Study of Chinese Subjects
    Chung, R.
    Narayanaswamy, A.
    Wong, T. Y.
    Park, J.
    Wong, W. L.
    Saw, S. M.
    Aung, T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)