Analysis of a Gas Cooling System for an Infrared Sensor Window

被引:0
|
作者
Xuan, Zhefeng [1 ]
Goo, Nam Seo [1 ]
机构
[1] Konkuk Univ, Dept Adv Technol Fus, Seoul 143701, South Korea
关键词
Infrared sensor window; Cooling system; Steady state; Transient;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a cooling system for an infrared sensor window was analyzed. We applied the same conditions used in an experiment to a numerical analysis. For the heat-fluid-structure interaction analysis, we used a commercial professional heat-fluid-structure analysis program. The results of the analysis were found to be in good agreement with those of the experiment. Under steady-state conditions, the temperature distribution on the top surface of the window from the simulation results was a little higher than that from the experimental results. The rates of temperature increase in the transient simulation and the experiment were almost identical.
引用
收藏
页码:1420 / 1424
页数:5
相关论文
共 50 条
  • [31] Key Technique Analysis of Data Fusion with Infrared Sensor in Defense System
    Chen, Hui
    Feng, Xiaolin
    Liu, Chaorong
    [J]. 2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 6938 - 6942
  • [32] A 3.0-3.7 μm Infrared Sensor System for Cell Analysis
    van den Driesche, Sander
    Witarski, Wojciech
    Vellekoop, Michael J.
    [J]. SMART SENSORS, ACTUATORS, AND MEMS IV, 2009, 7362
  • [33] Design of a hybrid modular sensor system for gas and odor analysis
    Mitrovics, J
    Ulmer, H
    Noetzel, G
    Weimar, U
    Gopel, W
    [J]. TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 1355 - 1358
  • [34] Gas mixture analysis using a distributed chemical sensor system
    Eklöv, T
    Lundström, I
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3): : 274 - 282
  • [35] Gas mixture analysis using a distributed chemical sensor system
    Eklöv, T
    Lundström, I
    [J]. EUROSENSORS XII, VOLS 1 AND 2, 1998, : 587 - 590
  • [36] Experimental research on near-infrared CO gas analysis system for natural gas
    Li, Guolin
    Liu, Wenya
    Ji, Wenhai
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48
  • [37] THERMAL WINDOW LOUVER SYSTEM REDUCES HEATING AND COOLING LOADS
    MECKLER, G
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (02): : 36 - 41
  • [38] A WINDOW FOURIER-DOMAIN INFRARED SEARCH SYSTEM
    SHERMAN, JW
    DEHASETH, JA
    CAMERON, DG
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (08) : 1311 - 1316
  • [39] Study on the window cooling system of 300 keV Electron Accelerator
    Leo, K. W.
    Chulan, R. M.
    Hashim, S. A.
    Azhar, M.
    Dalim, Y.
    Mokhtar, M.
    Baijan, A. H.
    Sabri, R. M.
    Faiz, M.
    Azaman, A.
    Rosli, R. C.
    [J]. INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [40] System design and analysis concept of a highly adaptable NDIR sensor for gas analysis
    Graf, Alexander
    Mielenz, Holger
    Sauer, Maximilian
    Arndt, Michael
    Gerlach, Gerald
    [J]. TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,