NON-RIGID BIOMEDICAL IMAGE REGISTRATION USING GRAPH CUTS WITH A NOVEL DATA TERM

被引:0
|
作者
Chowdhury, Ananda S. [1 ]
Roy, Rounak [1 ]
Bose, Sumon Kr [1 ]
Khalifa, Fahmi [2 ]
Elnakib, Ahmed [2 ]
El-Baz, Ayman [2 ]
机构
[1] Jadavpur Univ, Dept Elect & Telecommun Engn, Kolkata 700032, India
[2] Univ Louisville, Dept Bioengn, BioImaging Lab, Louisville, KY 40292 USA
关键词
Non-rigid registration; graph cuts; data term; brain MRI; retinal images;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Problem of non-rigid registration has become very important in the area of biomedical imaging. A non-rigid registration problem is modeled as an optimization problem and is solved using graph cuts and MRFs in recent years. In this paper, we have improved the graph cuts-based solution to non-rigid registration with a novel data term. The proposed data term has several advantages. Firstly, displacement labels can be directly assigned from this data term. Secondly, our data term imposes stricter penalty for intensity mismatches and hence yields higher registration accuracy. Finally, this data term can efficiently handle the dissimilarities in the intensity patterns between the floating and the reference images which may also arise due to some changes in illumination in addition to motion. We show the effectiveness of the proposed method on MRI images of brain and light microscopy images of retina. Experimental results indicate the superiority of our technique over some well-known non-rigid registration algorithms.
引用
收藏
页码:446 / 449
页数:4
相关论文
共 50 条
  • [41] Two algorithms for non-rigid image registration and their evaluation
    Xie, ZY
    Ng, L
    Gee, J
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 157 - 164
  • [42] Non-rigid Image Registration with Spatial Structure Preservation
    Bi, Dongsheng
    Zhu, Yanhui
    [J]. 2018 26TH INTERNATIONAL CONFERENCE ON GEOINFORMATICS (GEOINFORMATICS 2018), 2018,
  • [43] NON-RIGID IMAGE REGISTRATION - HOW DOES IT WORK?
    Hawkes, D.
    McClelland, J.
    Modat, M.
    Roth, H.
    Ourselin, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S185 - S185
  • [44] Effect of optimization framework on rigid and non-rigid multimodal image registration
    Chakraborty, Sayan
    Pradhan, Ratika
    Dey, Nilanjan
    Gonzalez Crespo, Ruben
    Tavares, Joao Manuel R. S.
    [J]. SCIENCEASIA, 2022, 48 : 1 - 11
  • [45] A novel learning-based dissimilarity metric for rigid and non-rigid medical image registration by using Bhattacharyya Distances
    So, Ronald W. K.
    Chung, Albert C. S.
    [J]. PATTERN RECOGNITION, 2017, 62 : 161 - 174
  • [46] Non-rigid point set registration using color and data downsampling
    Saval-Calvo, Marcelo
    Orts-Escolano, Sergio
    Azorin-Lopez, Jorge
    Garcia-Rodriguez, Jose
    Fuster-Guillo, Andres
    Morell-Gimenez, Vicente
    Cazorla, Miguel
    [J]. 2015 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2015,
  • [47] Optimized imaging using non-rigid registration
    Berkels, Benjamin
    Binev, Peter
    Blom, Douglas A.
    Dahmen, Wolfgang
    Sharpley, Robert C.
    Vogt, Thomas
    [J]. ULTRAMICROSCOPY, 2014, 138 : 46 - 56
  • [48] Non-rigid registration using distance functions
    Paragios, N
    Rousson, M
    Ramesh, V
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2003, 89 (2-3) : 142 - 165
  • [49] A novel scheme for automatic non-rigid image registration using deformation invariant feature and geometric constraint
    Deng, Zhipeng
    Lei, Lin
    Zhou, Shilin
    [J]. IMAGE AND SIGNAL PROCESSING FOR REMOTE SENSING XXI, 2015, 9643
  • [50] Hausdorff distance based non-rigid image registration using feature points
    Peng Xiaoming
    Chen Wufan
    Ma Qian
    [J]. 2006 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS PROCEEDINGS, VOLS 1-4: VOL 1: SIGNAL PROCESSING, 2006, : 442 - +