Cooling tower fill fouling control in a geothermal power plant

被引:0
|
作者
Yu, FP [1 ]
Ginn, LD [1 ]
McCoy, WF [1 ]
机构
[1] Nalco Chem Co, Nalco Ctr 1, Naperville, IL 60563 USA
来源
CORROSION REVIEWS | 1999年 / 17卷 / 3-4期
关键词
film fill; cooling tower; biofouling; biocide; biodispersant; biodetergent; thermal efficiency;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Since its first introduction to the market in the 1970s, cooling tower film fill technology has significantly increased thermal performance and reduced the size of cooling towers. However, the narrow spaces between film fill sheets make them more susceptible to fouling. Without proper chemical treatment, deposits can accumulate within the film fill resulting in reduced tower efficiency, increased fouling and plugging of the fill. These phenomena could eventually lead to collapse of the tower structure. This paper describes a new approach to remedy the high efficiency film fill fouling problem in a geothermal power plant. The plant has a long history of fill fouling problems due to complex make-up water chemistry and desert-related environmental conditions. In recent years, various biocide and biodispersant treatments have significantly improved fouling control by slowing down tower fill deposition rates. However, no program has been successful in reducing fill weight gain, especially during the summer months. Within six weeks after starting a new control program, the average weight of the tower fill deposits dropped 22% and thermal performance of the cooling tower increased 20%. The treatment resulted in significant improvements in cooling tower operation and power generation efficiency.
引用
收藏
页码:205 / 217
页数:13
相关论文
共 50 条
  • [31] NUMERICAL ANALYSIS OF COOLING TOWER WATER FOULING IN ENHANCED TUBES
    Fu, Ping
    Li, Hong-Xia
    Li, Wei
    Du, Yi-Lin
    Xiao, Sheng-Lan
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 4, 2014,
  • [32] Modeling oscillatory fouling in enhanced tubes in cooling tower systems
    Jie Wu
    Zhengjiang Zhang
    Lin Cheng
    Wei Li
    Zhiming Xu
    Heat and Mass Transfer, 2011, 47 : 563 - 569
  • [33] Modeling oscillatory fouling in enhanced tubes in cooling tower systems
    Wu, Jie
    Zhang, Zhengjiang
    Cheng, Lin
    Li, Wei
    Xu, Zhiming
    HEAT AND MASS TRANSFER, 2011, 47 (05) : 563 - 569
  • [34] Design and erection of the cooling tower at the Niederaußem power plant, unit K
    Busch, D.
    VGB PowerTech, 2001, 81 (03): : 91 - 95
  • [35] Hardness removal of wastewater of power plant cooling tower using electrocoagulation system
    Arabian, Daryush
    Pouretedal, Hamidreza
    DESALINATION AND WATER TREATMENT, 2023, 289 : 50 - 61
  • [37] Batch and continuous bleaching regimen in the cooling tower of Montazer Ghaem power plant
    Afshar, Majid Ghahraman
    Azimi, Mohammadrerza
    Habibi, Nemat
    Masihi, Hamidreza
    Esameilpour, Mohsen
    JOURNAL OF HAZARDOUS MATERIALS ADVANCES, 2023, 11
  • [38] Optimized operation of a cooling pond tower system for a steam cycle power plant
    Beckman, WA
    Mitchell, JW
    Kirchoff, J
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59 - PTS I AND II, 1997, 59 : 962 - 967
  • [39] Optimized operation of a cooling pond tower system for a steam cycle power plant
    Beckman, WA
    Mitchell, JW
    Kirchhoff, J
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59, I AND II, 1997, 59 : 962 - 967
  • [40] EVALUATING POWER-PLANT COOLING-TOWER BLOWDOWN REDUCTION METHODS
    NELSON, GR
    MECHANICAL ENGINEERING, 1975, 97 (04) : 67 - 68