Fundamental performance differences of CMOS and CCD imagers: Part VI

被引:8
|
作者
Janesick, James [1 ]
Elliott, Tom [1 ]
Andrews, James [2 ]
Tower, John [2 ]
机构
[1] SRI Sarnoff, Huntington Beach, CA 92649 USA
[2] SRI Sarnoff, Princeton, NJ 08543 USA
关键词
CMOS and CCD scientific imagers;
D O I
10.1117/12.2189941
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Past papers demonstrated advancements made on developing scientific PMOS/NMOS CMOS imagers that match or exceed CCD performance. New data and discussions presented in this paper present further progress on subject matters that include: 1). subcarrier read noise performance with understandings for how the noise floor can be reduced further, 2). comprehensive correlated double sampling (CDS) signal processing noise fundamentals in response to random telegraph and flicker noise sources, 3). high energy radiation damage test data from NASA's BSI SoloHi/WISPR CMOS imager and 4). update on a new scientific BSI PMOS/NMOS stitched Mk x Nk x 10 um 5TPPD pixel imager being fabricated for Lawrence Livermore National Lab (LLNL) and NASA's Europa Clipper mission.
引用
收藏
页数:17
相关论文
共 50 条
  • [42] Active control of environmental noise, VI: Performance of a fundamental free-field sound cancelling system
    Wright, SE
    Atmoko, H
    [J]. JOURNAL OF SOUND AND VIBRATION, 2001, 245 (04) : 581 - 609
  • [43] Imaging Performance Comparison of Novel CMOS Low-light-level Image Sensor and Electron Multiplying CCD Sensor
    Yang, Song
    Zhuang, Xuxia
    Xue, Fang
    Sun, Qian
    Ruan, Ningjuan
    [J]. AOPC 2017: OPTICAL SENSING AND IMAGING TECHNOLOGY AND APPLICATIONS, 2017, 10462
  • [44] Modelling and testing the x-ray performance of CCD and CMOS APS detectors using numerical finite element simulations
    Weatherill, Daniel P.
    Stefanov, Konstantin D.
    Greig, Thomas A.
    Holland, Andrew D.
    [J]. HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VI, 2014, 9154
  • [45] Charged aerosol detection and evaporative light scattering detection - Fundamental differences affecting analytical performance
    Acworth, I
    Thomas, D.
    [J]. PLANTA MEDICA, 2014, 80 (10) : 825 - 825
  • [46] The Importance of Fundamental Motor Skills in Identifying Differences in Performance Levels of U10 Soccer Players
    Jukic, Ivan
    Prnjak, Katarina
    Zoeliner, Anja
    Tufano, James J.
    Sekulic, Damir
    Salaj, Sanja
    [J]. SPORTS, 2019, 7 (07)
  • [47] On the Fundamental Differences between the NT and the KM Center of Sets Calculation Methods on the IT2-FLC Performance
    Sakalli, Ahmet
    Kumbasar, Tufan
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE 2015), 2015,
  • [48] Optimized mechanical performance of welded and molded butt joints: Part I - Similarities and differences
    Kagan, V
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2003, 22 (09) : 773 - 784
  • [49] HIGH-PERFORMANCE SALICIDE SHALLOW-JUNCTION CMOS DEVICES FOR SUBMICROMETER VLSI APPLICATION IN TWIN-TUB-VI
    LU, CY
    SUNG, JJ
    KIRSCH, HC
    TSAI, NS
    LIU, RC
    MANOCHA, AS
    HILLENIUS, SJ
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1989, 36 (11) : 2530 - 2536
  • [50] Performance differences in laparoscopic surgical skills between true high-definition and three-chip CCD video systems
    M. Hagiike
    E. H. Phillips
    G. Berci
    [J]. Surgical Endoscopy, 2007, 21 : 1849 - 1854