The effects of a surfactant on the mass transfer in spray-tower extraction column

被引:24
|
作者
Chen, LH [1 ]
Lee, YL [1 ]
机构
[1] Chia Nan Coll Pharm & Sci, Dept Appl Chem, Tainan 717, Taiwan
关键词
extraction; mass transfer coefficient; interfacial area; surfactant; dynamic surface effects;
D O I
10.1016/S1385-8947(99)00028-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For an extraction process, the overall efficiency of mass transfer is determined by the mass transfer coefficient and the interfacial area. A small amount of surfactant has the effect of decreasing the mass transfer coefficient while increasing the interfacial area. The extraction efficiency thus varies in a complex manner with the concentration of surfactant due to the two competing factors. To obtain a better understanding of these effects, the two factors were studied individually. A single-drop extraction apparatus was used to study the effects of a surfactant on the mass transfer coefficient in a previous work. In this work, the effects of a surfactant on the overall efficiency and mass transfer area were investigated in a spray-tower extraction column. The results show that sodium lauryl sulphate (SLS) has a negative effect on the overall efficiency. The value of K(R)a decreases rapidly with increasing SLS concentration, approaches a minimum at about 10 ppm, and then increases monotonically with further addition of SLS. With increasing surfactant concentration, the interfacial area increases more rapidly at a low SLS concentration, which is mainly due to the inhibition of drop coalescence by the dynamic surface effect. However, the slower increasing rate of mass transfer area at higher SLS concentrations results from a decrease in drop size with decreasing interfacial tension. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [41] Mass transfer coefficients in mixer-settler extraction column
    Nii, S
    Suzuki, J
    Tani, K
    Takahashi, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1997, 30 (06) : 1083 - 1089
  • [42] Enzyme mass transfer coefficient in a sieve plate extraction column
    Bhawsar, P.C.M.
    Pandit, A.B.
    Sawant, S.B.
    Joshi, J.B.
    1600, Elsevier Sequoia SA, Lausanne, Switzerland (55): : 1 - 2
  • [43] Investigation of the mass transfer parameters of caffeine extraction in a packed column
    Bilgin, Mehmet
    Hasdemir, I. Metin
    Aydin, Ahmet
    Dramur, Umur
    Turkish Journal of Engineering & Environmental Sciences/Turk Muhendislik ve Cevre Bilimleri Dergisi, 22 (06): : 471 - 477
  • [44] EXTRACTION IN A PILOT-UNIT SPRAY TOWER
    GEANKOPLIS, CJ
    WELLS, PL
    HAWK, EL
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1951, 43 (08): : 1848 - 1856
  • [45] MASS TRANSFER AND DEODORIZATION EFFICIENCY IN A COUNTERCURRENT SPRAY TOWER FOR LOW SUPERFICIAL GAS VELOCITIES
    Turpin, A.
    Couvert, A.
    Laplanche, A.
    Paillier, A.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2009, 87 (01): : 53 - 59
  • [46] Lipoxygenase-1 mass-transfer coefficient in aqueous two-phase system using spray extraction column
    Arsalani, V
    Rostami, K
    Kheirolomoom, A
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (19) : 7469 - 7473
  • [47] Mass transfer analysis of the extraction of Cr(VI) by liquid surfactant membrane
    Banerjea, S
    Datta, S
    Sanyal, SK
    SEPARATION SCIENCE AND TECHNOLOGY, 2000, 35 (04) : 483 - 501
  • [48] Surfactant mass transfer effects on drop detachment.
    Jin, F
    Stebe, KJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U651 - U651
  • [49] Mass transfer characteristics in extraction column with trapezoidal pulsed sieve plate
    Zhang, Weibo
    Dai, Weizhi
    Hu, Xi'en
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 1993, 7 (03): : 214 - 220
  • [50] MASS-TRANSFER AND AXIAL-DISPERSION IN A KUHNI EXTRACTION COLUMN
    DONGAONKAR, KR
    PRATT, HRC
    STEVENS, GW