Progression of Emphysema Evaluated by MRI Using Hyperpolarized 3He (Hp 3He) Measurements in Patients with Alpha-1-Antitrypsin (A1AT) Deficiency Compared with CT and Lung Function Tests

被引:13
|
作者
Stavngaard, T. [1 ]
Sogaard, L. Vejby [1 ]
Batz, M. [2 ]
Schreiber, L. M. [3 ]
Dirksen, A. [4 ]
机构
[1] Copenhagen Univ Hosp, Danish Res Ctr Magnet Resonance, Hvidovre, Denmark
[2] Johannes Gutenberg Univ Mainz, Inst Phys, D-6500 Mainz, Germany
[3] Johannes Gutenberg Univ Mainz, Sch Med, Dept Intervent & Diagnost Radiol, Mainz, Germany
[4] Univ Copenhagen, Gentofte Hosp, Dept Resp Med, Copenhagen, Denmark
关键词
ADC; emphysema; hyperpolarized gas; lung; MRI; progression; DIFFUSION-COEFFICIENT; MAGNETIC-RESONANCE; COMPUTED DENSITY; MORPHOMETRY; GAS; POLARIZATION; VENTILATION; DEFINITION; RELAXATION; SMOKERS;
D O I
10.3109/02841850903213822
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The progression of emphysema is traditionally measured by pulmonary function test, with forced expiratory volume in 1 s (FEV1) being the most accepted and used measurement. However, FEV1 is insensitive in detecting mild/slow progression of emphysema because of low reproducibility as compared to yearly decline. Purpose: To investigate the progression of emphysema over a period of 2 years using diffusion-weighted hyperpolarized (HP) He-3 magnetic resonance imaging (MRI) in patients with alpha-1-antitrypsin (A1AT) deficiency. Material and Methods: Nine patients with severe A1AT deficiency were studied over a period of 2 years (baseline, year 1, and year 2) with Hp He-3 MRI using apparent diffusion coefficient (ADC), lung function tests (FEV1 and carbon monoxide lung diffusion capacity [D-L,D-CO]), and computed tomography (CT) using densitometric parameters (15th percentile density [CT-PD15] and relative area of emphysema below -910 HU [CT-RA-910]). Results: Seven patients were scanned three times, one patient two times, and one patient only at baseline. The mean increase in ADC values from first to last Hp He-3 MR scanning was 3.8% (0.014 cm (2)/s [SD 0.024 cm(2)/s]; not significant). The time trends for FEV1, D-L,D-CO, CT-PD15, and CT-RA-910 were all statistically significant. We found a high correlation between ADC and D-L,D-CO (P<0.001). Conclusion: This pilot study indicates the possible use of nonionizing HP He-3 MRI for monitoring the progression of emphysema. However, in the future, larger studies are needed to confirm these preliminary results.
引用
收藏
页码:1019 / 1026
页数:8
相关论文
共 50 条
  • [31] Free-breathing Pulmonary 1H and Hyperpolarized 3He MRI: Comparison in COPD and Bronchiectasis
    Capaldi, Dante P. I.
    Sheikh, Khadija
    Guo, Fumin
    Svenningsen, Sarah
    Etemad-Rezai, Roya
    Coxson, Harvey O.
    Leipsic, Jonathon A.
    McCormack, David G.
    Parraga, Grace
    ACADEMIC RADIOLOGY, 2015, 22 (03) : 320 - 329
  • [32] Comparison of 1H MRI and 3He MRI ventilation images in patients with cystic fibrosis and patients with lung cancer
    Marshall, Helen
    Voskrebenzev, Andreas
    Biancardi, Alberto
    Smith, Laurie
    Tahir, Bilal
    Wild, Jim
    Vogel-Claussen, Jens
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [33] Interpretation of multiple breath washout (MBW) measurements of lung function using mathematical modelling and hyperpolarised 3He gas MRI
    Whitfield, Carl
    Smith, Laurie
    Jensen, Oliver
    West, Noreen
    Wildman, Martin
    Collier, Guilhem
    Wild, Jim
    Horsley, Alex
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [34] Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales:: Comparison with healthy subjects and patients with COPD
    Wang, Chengbo
    Altes, Talissa A.
    Mugler, John P., III
    Miller, G. Wilson
    Ruppert, Kai
    Mata, Jaime F.
    Cates, Gordon D., Jr.
    Borish, Larry
    de lange, Eduard E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 80 - 88
  • [35] Hyperpolarized 3He MR for Sensitive Imaging of Ventilation Function and Treatment Efficiency in Young Cystic Fibrosis Patients with Normal Lung Function
    Bannier, Elise
    Cieslar, Katarzyna
    Mosbah, Karim
    Aubert, Francoise
    Duboeuf, Francois
    Salhi, Zahir
    Gaillard, Sophie
    Berthezene, Yves
    Cremillieux, Yannick
    Reix, Philippe
    RADIOLOGY, 2010, 255 (01) : 225 - 232
  • [36] Imaging of the lungs using 3He MRI: Preliminary clinical experience in 18 patients with and without lung disease
    Kauczor, HU
    Ebert, M
    Kreitner, KF
    Nilgens, H
    Surkau, R
    Heil, W
    Hofmann, D
    Otten, EW
    Thelen, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 538 - 543
  • [37] Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan
    Miller, GW
    Altes, TA
    Brookeman, JR
    de Lange, EE
    Mugler, JP
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (05) : 218 - 226
  • [38] A Model for Predicting Future FEV1 Decline in Smokers Using Hyperpolarized 3He Magnetic Resonance Imaging
    Baron, Ryan J.
    Hamedani, Hooman
    Kadlecek, Stephen J.
    Duncan, Ian F.
    Xin, Yi
    Siddiqui, Sarmad
    Pourfathi, Mehrdad
    Cereda, Maurizio
    Rizi, Rahim R.
    ACADEMIC RADIOLOGY, 2019, 26 (03) : 383 - 394
  • [39] Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan
    G. W. Miller
    T. A. Altes
    J. R. Brookeman
    E. E. de Lange
    J. P. Mugler III
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 218 - 226
  • [40] Hyperpolarized 3He diffusion MRI and histology of secreted frizzled related protein-1 (SFRP1) deficient lungs in a Murine model
    Siddiqui, Sarmad
    Xin, Yi
    Emami, Kiarash
    D'Armiento, Jeanine
    Shiomi, Takayuki
    Profka, Harrilla
    Mongkolwisetwara, Puttisarn
    Rizi, Rahim
    MAGNETIC RESONANCE IMAGING, 2014, 32 (05) : 535 - 540