Comparison of pedometer and accelerometer measures of free-living physical activity

被引:292
|
作者
Tudor-Locke, C
Ainsworth, BE
Thompson, RW
Matthews, CE
机构
[1] Arizona State Univ, Dept Exercise & Wellness, Mesa, AZ 85212 USA
[2] Univ S Carolina, Dept Epidemiol, Columbia, SC USA
[3] Univ S Carolina, Dept Biostat, Columbia, SC USA
[4] Univ S Carolina, Dept Exercise Sci, Columbia, SC USA
来源
关键词
motion sensors; movement; behavior; exercise; ambulatory monitoring;
D O I
10.1097/00005768-200212000-00027
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purpose of this investigation was 1) to evaluate agreement between dual-mode CSA accelerometer outputs and Yamax pedometer outputs assessed concurrently under free-living conditions; 2) to determine the relationship between pedometer-steps per day and CSA-time spent in inactivity and in light-, moderate-, and vigorous- intensity activities; and 3) to identify a value of pedometer-steps per day that corresponds with a minimum of 30 CSA-min.d(-1) of moderate ambulatory activity. Methods: Data were analyzed from 52 participants (27 men, 25 women; mean age = 38.2 +/- 12.0 yr; mean BMI = 26.4 +/- 4.5 kg.m(-2)) who were enrolled in the International Physical Activity Questionnaire study and wore both motion sensors during waking hours for 7 consecutive days. Results: Participants averaged 415.0 +/- 159.5 CSA-counts.min(-1).d(-1), 357,601 +/- 138,425 CSA-counts.d(-1), 11,483 +/- 3,856 CSA-steps.d(-1), and 9,638 +/- 4,030 pedometer-steps.d(-1). There was a strong relationship between all CSA outputs and pedometer outputs (r = 0.74-0.86). The mean difference in steps detected between instruments was 1845 +/- 2116 steps.d(-1) (CSA > pedometer; t = 6.29, P < 0.0001). There were distinct differences (effect sizes >0.80) in mean CSA-time (min.d(-1)) in moderate and vigorous activity with increasing pedometer-determined activity quartiles; no differences were noted for inactivity or light activity. Approximately 33 CSA-min.d(-1) of moderate activity corresponded with 8000 pedometer-steps.d(-1). Conclusion: Differences in mean steps per day detected may be due to differences in set instrument sensitivity thresholds and/or attachment. Additional studies with different populations are needed to confirm a recommended number of steps per day associated with the duration and intensity of public health recommendations for ambulatory activity.
引用
收藏
页码:2045 / 2051
页数:7
相关论文
共 50 条
  • [31] Physical activity in confined conditions as an indicator of free-living physical activity
    Westerterp, KR
    Kester, ADM
    OBESITY RESEARCH, 2003, 11 (07): : 865 - 868
  • [32] Validation of the RT3 accelerometer for measuring physical activity of children in simulated free-living conditions
    Sun, David Xiaoqian
    Schmidt, Gordon
    Teo-Koh, Sock Miang
    PEDIATRIC EXERCISE SCIENCE, 2008, 20 (02) : 181 - 197
  • [33] Estimating Free-living Physical Activity Using A Wrist-worn Actigraph Accelerometer: Can It Be Done?
    Petrucci, Greg J., Jr.
    Marcotte, Robert T.
    Cox, Melanna F.
    Staudenmayer, John
    Freedson, Patty S.
    Sirard, John R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 164 - 165
  • [34] Physical activity classification in free-living conditions using smartphone accelerometer data and exploration of predicted results
    Lee, Kangjae
    Kwan, Mei-Po
    COMPUTERS ENVIRONMENT AND URBAN SYSTEMS, 2018, 67 : 124 - 131
  • [35] Classification of accelerometer wear and non-wear events in seconds for monitoring free-living physical activity
    Zhou, Shang-Ming
    Hill, Rebecca A.
    Morgan, Kelly
    Stratton, Gareth
    Gravenor, Mike B.
    Bijlsma, Gunnar
    Brophy, Sinead
    BMJ OPEN, 2015, 5 (05):
  • [36] A Comparison of Two Motion Sensors for the Assessment of Free-Living Physical Activity of Adolescents
    Cuberek, Roman
    El Ansari, Walid
    Fromel, Karel
    Skalik, Krzysztof
    Sigmund, Erik
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2010, 7 (04): : 1558 - 1576
  • [37] Activity Detection in Uncontrolled Free-living Conditions Using a Single Accelerometer
    Lee, Sunghoon Ivan
    Ozsecen, Muzaffer Yalgin
    Della Toffola, Luca
    Daneault, Jean-Francois
    Puiatti, Alessandro
    Patel, Shyamal
    Bonato, Paolo
    2015 IEEE 12TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2015,
  • [38] Comparisons of Accelerometer and Pedometer Determined Steps in Free Living Samples
    Behrens, Timothy K.
    Dinger, Mary K.
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2011, 8 (03): : 390 - 397
  • [39] Comparison of two ActiGraph accelerometer generations in the assessment of physical activity in free living conditions
    Vanhelst J.
    Mikulovic J.
    Bui-Xuan G.
    Dieu O.
    Blondeau T.
    Fardy P.
    Béghin L.
    BMC Research Notes, 5 (1)
  • [40] Calculating an Actical Accelerometer Cut Point in Free Living Conditions through Comparison with Pedometer Data
    Holleman, Robert G.
    Ronis, David L.
    Richardson, Caroline R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S204 - S204