Copper-film electrodes for Pb(II) trace analysis and a detailed electrochemical impedance spectroscopy study

被引:16
|
作者
Finsgar, Matjaz [1 ]
Xhanari, Klodian [1 ,2 ]
Petovar, Barbara [1 ]
机构
[1] Univ Maribor, Fac Chem & Chem Engn, Smetanova Ulica 17, SLO-2000 Maribor, Slovenia
[2] Univ Tirana, Fac Nat Sci, Blvd Zogu 1, Tirana 1001, Albania
关键词
Copper-film electrode; Electrochemical impedance spectroscopy; Anodic stripping voltammetry; Method optimisation; Method validation; ANODIC-STRIPPING VOLTAMMETRY; CARBON ELECTRODE; BISMUTH; ANTIMONY; CADMIUM(II); TIN; PB; MICROELECTRODE; NITRATE; METALS;
D O I
10.1016/j.microc.2019.04.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical performance of differently prepared in situ copper-film glassy carbon electrodes (CuFE) was compared with the bare glassy carbon electrode (GCE) for the electroanalytical determination of Pb(II) traces in a solution containing 0.1 M HCl and 0.4 M NaCl. Electrodes were prepared and validated for different accumulation potentials in order to check the influence of hydrogen evolution on the performance of the methods. The methods were first validated for limit of detection, linear concentration range, sensitivity, accuracy, and precision. The applicability of the CuFE method was also tested in a real sample analysis (local tap water). The main focus of this work is to understand the electroanalytical behaviour of such systems by performing a detailed electrochemical impedance spectroscopy (EIS) study at potentials that are more negative, just before, and more positive than the Pb(II) stripping signal develops. For comparison, the same analysis was also performed for the bare GCE. Moreover, the EIS spectra were also obtained at the open circuit potential in order to test the electrodeposited material. Different equivalent electrical circuits were employed in order to fully describe the situation on the electrodes surface. It was shown that the CuFE system is under kinetic control when the stripping signal is obtained, whereas it is under both kinetic and diffusion control at potentials more positive than the Pb (II) stripping peak potential. On the other hand, in the case of the bare GCE, the system is under both kinetic and diffusion control even before the analytical signal is obtained. This is the main electroanalytical difference between the modified and the non-modified electrodes and might be responsible for the differences in their analytical performances.
引用
收藏
页码:863 / 871
页数:9
相关论文
共 50 条
  • [11] Electrochemical Impedance Analysis of Polyaniline-Film on Tungsten Electrodes
    Chon, J.-K.
    Byoung Hoon Min
    Daehan Hwahak Hwoejee /Journal of the Korean Chemical Society, 40 (01):
  • [12] Electrochemical impedance spectroscopy study of silver cementation on copper
    Alemany, C
    Diard, JP
    LeGorrec, B
    Montella, C
    ELECTROCHIMICA ACTA, 1996, 41 (09) : 1483 - 1489
  • [13] Electrochemical impedance study of polypyrrole modified electrodes bearing bathophenanthroline disulfonate in copper analysis
    Shin, KK
    Zhang, YZ
    ELECTROCHIMICA ACTA, 1997, 42 (03) : 461 - 469
  • [14] Electrochemical impedance study and sensitive voltammetric determination of Pb(II) at electrochemically activated glassy carbon electrodes
    Zen, JM
    Chung, HH
    Hangovan, G
    Kumar, AS
    ANALYST, 2000, 125 (06) : 1139 - 1146
  • [15] Preparation of dendritic bismuth film electrodes and their application for detection of trace Pb (II) and Cd (II)
    Zhou, Huizhu
    Hou, Huanhuan
    Dai, Lei
    Li, Yuehua
    Zhu, Jing
    Wang, Ling
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2016, 24 (03) : 410 - 414
  • [16] Emerging Applications of Electrochemical Impedance Spectroscopy in Tear Film Analysis
    Ozdalgic, Berin
    Gul, Munire
    Uygun, Zihni Onur
    Atçeken, Nazente
    Tasoglu, Savas
    Biosensors, 2022, 12 (10):
  • [17] Emerging Applications of Electrochemical Impedance Spectroscopy in Tear Film Analysis
    Ozdalgic, Berin
    Gul, Munire
    Uygun, Zihni Onur
    Atceken, Nazente
    Tasoglu, Savas
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [18] Corrosion protection of copper by polypyrrole film studied by electrochemical impedance spectroscopy and the electrochemical quartz microbalance
    Lei, Yanhua
    Ohtsuka, Toshiaki
    Sheng, Nan
    APPLIED SURFACE SCIENCE, 2015, 357 : 1122 - 1132
  • [19] Study of copper dissolution and passivation processes by electrochemical impedance spectroscopy
    Folquer, ME
    Ribotta, SB
    Real, SG
    Gassa, LM
    CORROSION, 2002, 58 (03) : 240 - 247
  • [20] ANALYSIS OF ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY DATA FOR LITHIUM ELECTRODES AND LITHIUM BATTERIES
    BAGOTZKY, VS
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 357 (1-2): : 251 - 259