Study on Transient Voltage Stability of Wind Farm Incorporated System with Reactive Power Compensation Device

被引:0
|
作者
Huang, Tiezheng [1 ]
Ma, Jie [1 ]
Wang, Wei [1 ]
机构
[1] Econ & Tech Res Inst SEPC SGCC, Taiyuan 030002, Shanxi, Peoples R China
关键词
wind power generation; transient voltage stability; dynamic reactive compensation; BPA;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the rapid development of wind power generation technology in recent years, it has caused a number of new problems when large scale wind electricity incorporates into power system. One of the most serious problems is that the randomness and volatility of wind generation output or grid fault may lead wind farm to quit operation totally, then power balance of the system is broken and the transient voltage stability of the system is seriously threatened. Therefore, it's quite necessary to study transient voltage stability of the power system with wind power generation incorporated. Above all, the mechanism of transient voltage instability is explained. A model of an actual electrical network, with large-scale incorporation wind electricity 50% to the total installed, is built in BPA. Based on electrical network model, the simulation design and analysis are carried on in detailed. As wind speed fluctuation and short circuit fault are two common kinds of disturbances in wind power integrated system, we study the influences on the transient voltage stability of the system in both cases. On this basis, as SVC and STATCOM are two dynamic reactive compensation devices, their abilities of system voltage supporting are analyzed by comparing the voltage wave forms in cases of SVC or STATCOM being configured or not. Results show that, it can cause adverse impact in both cases of wind speed fluctuation and short circuit fault. When wind speed suddenly increases the voltage of the system decreases. While with SVC or STATCOM configured in the power system, decreasing extent of system voltage is reduced in case of wind speed suddenly changing. The results also show that the voltage supporting function is more obvious when STATCOM is configured than SVC. As for cases of single-phase grounding fault and three-phase grounding fault, when the fault occurs the voltage of the system decreases. But when SVC or STATCOM is configured in the power system, decreasing extent of system voltage is reduces. It can be observed that the dynamic reactive power compensation devices STATCOM has a greater contribution on system voltage supporting, it is more effective in the field of reactive power compensation than SVC.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Reactive Power Compensation In Order To Improve Static Voltage Stability in a Network with Wind Generation
    Eidiani, Mostafa
    Ashkhane, Yasser
    Khederzadeh, Mojtaba
    [J]. SECOND INTERNATIONAL CONFERENCE ON COMPUTER AND ELECTRICAL ENGINEERING, VOL 1, PROCEEDINGS, 2009, : 47 - +
  • [32] Reactive power optimization of power system with wind farm
    Wang, Hong
    Wang, Zhijie
    [J]. PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 5768 - 5771
  • [33] Improvement of Transient Voltage Stability of the Wind Farm using SVC
    Zhao, Yongbin
    Yang, Jun
    Sun, Qiuye
    Huang, Xu
    [J]. PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 653 - +
  • [34] Study on the Mechanism of Transient Voltage Stability of Wind Power With Power Electronic Interface
    Chen, Lei
    Dai, Yuanhang
    Min, Yong
    Hou, Kaiyuan
    [J]. 2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [35] Investigation of Wind Farm on Power System Voltage Stability Based on Bifurcation Theory
    Zeng, Zhiyuan
    Li, Xianqi
    Zhou, Jianzhong
    Zhang, Yongchuan
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2441 - 2444
  • [36] Reactive Power Compensation Solutions and Reactive Power Source Priority Impact on Wind Farm Losses
    Vegunta, Sarat Chandra
    Barlow, Mick J.
    Stapleton, Steve
    [J]. 2017 IEEE MANCHESTER POWERTECH, 2017,
  • [37] A Comparison among Reactive Power Compensation Strategies in Wind Farm Power Plant
    Calderaro, Vito
    Galdi, Vincenzo
    Conio, Gaspare
    Fusco, Roberto
    [J]. 2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [38] Reactive Power Voltage Stability Control of Power System with Wind Turbine Based on STATCOM
    Yao, Yan
    Gao, Feiling
    Zhou, Ziwang
    [J]. 2022 6TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING, ICPEE, 2022, : 31 - 36
  • [39] Wind Farm Power Plant: Optimal Capacitor Placement for Reactive Power Compensation
    Calderaro, Vito
    Galdi, Vincenzo
    Piccolo, Antonio
    Conio, Gaspare
    Fusco, Roberto
    [J]. 2013 4TH IEEE/PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2013,
  • [40] Study on Voltage Stability of Power Grid with Large Scale Wind Farm Interconnected
    Mi, Zengqiang
    Tian, Haifeng
    Yu, Yang
    Su, Xunwen
    Fan, Xiaowei
    Feng, Jinpeng
    [J]. 2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1333 - +