Simultaneous quantitative analysis of dextromethorphan, dextrorphan and chlorphenamine in human plasma by liquid chromatography-electrospray tandem mass spectrometry

被引:7
|
作者
Ding, Ying [1 ]
Huang, Kai [1 ]
Chen, Lan [1 ]
Yang, Jie [1 ]
Xu, Wen-Yan [1 ]
Xu, Xue-Jiao [1 ]
Duan, Ru [1 ]
Zhang, Jing [1 ]
He, Qing [1 ]
机构
[1] Nanjing Med Univ, Drug Clin Trial Inst, Wuxi Peoples Hosp, Wuxi 214023, Peoples R China
关键词
dextromethorphan; dextrorphan; chlorphenamine; HPLC-MS; MS; pharmacokinetics; CLINICAL PHARMACOKINETICS; METABOLITE DEXTRORPHAN; HUMAN URINE; LC-MS/MS; CHLORPHENIRAMINE; ASSAY; ANTIHISTAMINES; POPULATION; DEXTROPHAN;
D O I
10.1002/bmc.3054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and accurate HPLC-MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid-liquid extraction using ethyl acetate and separated on a Kromasil 60-5CN column (3 mu m, 2.1x150 mm) with mobile phase of acetonitrile-water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01-5 ng/mL for dextromethorphan, 0.02-5 ng/mL for dextrorphan and 0.025-20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra- and inter-day precisions were within 11% and accuracies were in the range of 92.9-102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg). Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:446 / 452
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry
    Lee, Chaelin
    Kim, Chong Hyeak
    Kim, Sunghwan
    Cho, Sung-Hee
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1058 : 8 - 13
  • [42] Simultaneous Determination of Seventeen Sulfonamide Residues in Chickens by Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Dong Dan
    Shao Bing
    Wu Yongning
    Wu Guohua
    Xue Ying
    Xu Shukun
    Tu Xiaoming
    Zhang Yanfeng
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (04) : 404 - 407
  • [43] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136
  • [44] Simultaneous determination of synthetic food additives in kimchi by liquid chromatography-electrospray tandem mass spectrometry
    Ho Jin Kim
    Mi Jin Lee
    Hye Jin Park
    Hye Jin Kim
    Soon Kil Cho
    Min Hee Jeong
    [J]. Food Science and Biotechnology, 2018, 27 : 877 - 882
  • [45] Simultaneous determination of multiple phytohormones in plant extracts by liquid chromatography-electrospray tandem mass spectrometry
    Durgbanshi, A
    Arbona, V
    Pozo, O
    Miersch, O
    Sancho, JV
    Gómez-Cadenas, A
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (22) : 8437 - 8442
  • [46] Measurement of dextromethorphan and dextrorphan in human urine using a novel isocratic liquid chromatography tandem mass spectrometry method
    McKeown, DA
    Lee, TD
    Holt, DW
    Johnston, A
    [J]. THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 222 - 222
  • [47] Determination of cortisol in human saliva using liquid chromatography-electrospray tandem mass spectrometry
    Jönsson, BAG
    Malmberg, B
    Amilon, A
    Garde, AH
    Orbæk, P
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (01): : 63 - 68
  • [48] Quantitative determination of armodafinil in human plasma by liquid chromatography-electrospray mass spectrometry: Application to a clinical study
    Chandasana, Hardik
    Kast, Johannes
    Bittman, Janina A.
    Derendorf, Hartmut
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (11)
  • [49] Quantitation of tamsulosin in human plasma by liquid chromatography-electrospray ionization mass spectrometry
    Ding, L
    Li, LM
    Tao, P
    Yang, J
    Zhang, ZX
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01): : 75 - 81
  • [50] Simultaneous analysis of 16 sulfonamide and trimethoprim antibiotics in environmental waters by liquid chromatography-electrospray tandem mass spectrometry
    Chang, Hong
    Hu, Jianying
    Asami, Mari
    Kunikane, Shoichi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1190 (1-2) : 390 - 393