Label-free electrochemical immunosensors for the detection of zeranol using graphene sheets and nickel hexacyanoferrate nanocomposites

被引:9
|
作者
Xue, Xiaodong [1 ]
Wei, Dong [1 ]
Feng, Rui [1 ]
Wang, Huan [2 ]
Wei, Qin [2 ]
Du, Bin [1 ]
机构
[1] Univ Jinan, Sch Resources & Environm Sci, Jinan 250022, Peoples R China
[2] Univ Jinan, Key Lab Chem Sensing & Anal Univ Shandong, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
关键词
SIGNAL AMPLIFICATION STRATEGY; NANOPARTICLES; OXIDE; FILM;
D O I
10.1039/c3ay40608c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel label-free electrochemical immunosensor has been developed by immobilizing graphene sheets (GS) and nickel hexacyanoferrate nanocomposites (NiNPs) for the detection of zeranol (ZER). NiNPs were used as electron transfer mediators, and electroactivity was greatly enhanced in the presence of GS, which was ascribed to the good electron-transfer ability of GS. The modification procedure was characterized by cyclic voltammetry (CV). The detection is based on the current change of the modified electrode before and after the antigen-antibody reaction. Under optimum conditions, the detection of ZER demonstrated that the immunosensor exhibited a wide linear range of 0.05-10.0 ng mL(-1) with a low detection limit of 6 pg mL(-1). The proposed immunosensor also showed good performances such as high sensitivity, good selectivity and stability. The reliability of the developed immunosensor has been proved by the detection of ZER in river water samples with satisfactory results.
引用
收藏
页码:4159 / 4164
页数:6
相关论文
共 50 条
  • [31] Label-Free Electrochemical Methods for Disease Detection
    Rahn, Kira L.
    Peramune, Umesha
    Zhang, Tianyi
    Anand, Robbyn K.
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2023, 16 (49-69) : 49 - 69
  • [32] Quinone-Based Polymers for Label-Free and Reagentless Electrochemical Immunosensors: Application to Proteins, Antibodies and Pesticides Detection
    Piro, Benoit
    Reisberg, Steeve
    Anquetin, Guillaume
    Huynh-Thien Duc
    Minh-Chau Pham
    BIOSENSORS-BASEL, 2013, 3 (01): : 58 - 76
  • [33] 1D ZnO-Au nanocomposites as label-free photoluminescence immunosensors for rapid detection of Listeria monocytogenes
    Myndrul, Valerii
    Yanovska, Anna
    Babayevska, Nataliya
    Korniienko, Viktoriia
    Diedkova, Kateryna
    Jancelewicz, Mariusz
    Pogorielov, Maksym
    Iatsunskyi, Igor
    TALANTA, 2024, 271
  • [34] Label-free electrochemical immunosensors based on surface-initiated atom radical polymerization
    Yuan, Liang
    Wei, Wei
    Liu, Songqin
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 79 - 85
  • [35] Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy
    Ortiz-Aguayo, Dionisia
    del Valle, Manel
    SENSORS, 2018, 18 (02)
  • [36] Graphene Nanoplatelets/Chitosan-Modified Electrochemical Immunosensor for the Label-Free Detection of Haptoglobin
    Adhikari, Juthi
    Mohd-Naim, Noor Faizah
    Ahmed, Minhaz Uddin
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4176 - 4183
  • [37] Label-free electrochemical aptasensor for thrombin detection based on the nafion@graphene as platform
    Sun, Tao
    Wang, Li
    Li, Na
    Gan, Xianxue
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (09) : 1081 - 1085
  • [38] Label-free and reagentless electrochemical genosensor based on graphene acid for meat adulteration detection
    Flauzino, Jose M. R.
    Nguyen, Emily P.
    Yang, Qiuyue
    Rosati, Giulio
    Panacek, David
    Brito-Madurro, Ana G.
    Madurro, Joao M.
    Bakandritsos, Aristides
    Otyepka, Michal
    Merkoci, Arben
    BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [39] Label-free electrochemical aptasensor for thrombin detection based on the nafion@graphene as platform
    Tao Sun
    Li Wang
    Na Li
    Xianxue Gan
    Bioprocess and Biosystems Engineering, 2011, 34 : 1081 - 1085
  • [40] Label-free amino acid detection based on nanocomposites of graphene oxide hybridized with gold nanoparticles
    Zhang, Qian
    Zhang, Diming
    Lu, Yanli
    Xu, Gang
    Yao, Yao
    Li, Shuang
    Liu, Qingjun
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 963 - 970