Effect of Postoperative Peroxide Bleaching on the Marginal Seal of Composite Restorations Bonded With Self-etch Adhesives

被引:9
|
作者
Roubickova, A. [1 ]
Dudek, M. [1 ]
Comba, L. [1 ]
Housova, D. [1 ]
Bradna, P. [1 ]
机构
[1] Charles Univ Prague, Inst Clin & Expt Dent Med, Fac Med 1, Gen Teaching Hosp, Prague, Czech Republic
关键词
HYDROLYTIC STABILITY; HYDROGEN-PEROXIDE; STRENGTH; RESIN; PERFORMANCE; LEAKAGE;
D O I
10.2341/12-385-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine the effect of peroxide bleaching on the marginal seal of composite restorations bonded with several adhesive systems. Combined cylindrical Class V cavities located half in enamel and half in dentin were prepared on the buccal and lingual surfaces of human molars. The cavities were bonded with the self-etch adhesives Clearfil SE-Bond (CLF), Adper Prompt (ADP), and iBond (IBO) and an etch-and-rinse adhesive Gluma Comfort Bond (GLU) and restored with a microhybrid composite Charisma. Experimental groups were treated 25 times for eight hours per day with a peroxide bleaching gel Opalescence PF 20, while the control groups were stored in distilled water for two months and then subjected to a microleakage test using a dye penetration method. Scanning electron microscopy was used to investigate the etching and penetration abilities of the adhesives and morphology of debonded restoration-enamel interfaces after the microleakage tests. Statistical analyses were performed using nonparametric Kruskal-Wallis, Mann-Whitney, and Wilcoxon tests at p=0.05. The microleakage of all GLU groups was low and not significantly affected by peroxide bleaching. Low microleakage was recorded for CLF control groups, but after bleaching, a small but significant increase in microleakage at the enamel margin indicated its sensitivity to peroxide bleaching. For ADP and IBO control groups, the microleakage at the enamel margins was significantly higher than for GLU and CLF and exceeded that at the dentin margins. Bleaching did not induce any significant changes in the microleakage. Electron microscopy analysis indicated that in our experimental setup, decreased adhesion and mechanical resistance of the ADP- and IBO-enamel interfaces could be more important than the chemical degradation effects induced by the peroxide bleaching gel.
引用
收藏
页码:644 / 654
页数:11
相关论文
共 50 条
  • [31] Total-etch versus self-etch adhesive - Effect on postoperative sensitivity
    Perdigao, J
    Geraldeli, S
    Hodges, JS
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2003, 134 (12): : 1621 - 1629
  • [32] Effect of chlorhexidine on the shear bond strength of self-etch adhesives to dentin
    Chaharom, Mohammad Esmaeel Ebrahimi
    Ajami, Amir Ahmad
    Kimyai, Soodabeh
    Abbasi, Ahmad
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (49): : 10054 - 10057
  • [33] Effect of dentin dehydration and composite resin polymerization mode on bond strength of two self-etch adhesives
    Samimi, Pooran
    Alizadeh, Mehdi
    Shirban, Farinaz
    Davoodi, Amin
    Khoroushi, Maryam
    CONTEMPORARY CLINICAL DENTISTRY, 2016, 7 (01) : 16 - 20
  • [34] Short-Term Comparison of Clinical Performance of Universal Adhesives with Self-Etch Mode in NCCL Restorations
    Karabay, Ferda
    Demirci, Mustafa
    Tuncer, Safa
    Tekce, Neslihan
    Berkman, Meric
    Baydemir, Canan
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2023, 31 (02): : 78 - 91
  • [35] Influence of the LED curing source and selective enamel etching on dentin bond strength of self-etch adhesives in class I composite restorations
    Eduardo José Souza-Junior
    Cíntia Tereza Pimenta Araújo
    Lúcia Trazzi Prieto
    Luís Alexandre Maffei Sartini Paulillo
    Lasers in Medical Science, 2012, 27 : 1175 - 1182
  • [36] Effect of EDTA conditioning on cervical restorations bonded with a self-etch adhesive: A randomized double-blind clinical trial
    Luque-Martinez, Issis
    Angel Munoz, Miguel
    Mena-Serrano, Alexandra
    Hass, Viviane
    Reis, Alessandra
    Loguercio, Alessandro D.
    JOURNAL OF DENTISTRY, 2015, 43 (09) : 1175 - 1183
  • [37] Influence of the LED curing source and selective enamel etching on dentin bond strength of self-etch adhesives in class I composite restorations
    Souza-Junior, Eduardo Jose
    Pimenta Araujo, Cintia Tereza
    Prieto, Lucia Trazzi
    Maffei Sartini Paulillo, Luis Alexandre
    LASERS IN MEDICAL SCIENCE, 2012, 27 (06) : 1175 - 1182
  • [38] Effect of cyclic loading on the microtensile bond strengths of total-etch and self-etch adhesives
    Toledano, M
    Osorio, R
    Albaladejo, A
    Aguilera, FS
    Tay, FR
    Ferrari, M
    OPERATIVE DENTISTRY, 2006, 31 (01) : 25 - 32
  • [39] Effect of acidic monomer concentration on the dentin bond stability of self-etch adhesives
    Leal, Fernanda B.
    Madruga, Francine C.
    Prochnow, Emilia P.
    Lima, Giana S.
    Ogliari, Fabricio A.
    Piva, Evandro
    Moraes, Rafael R.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2011, 31 (06) : 571 - 574
  • [40] Microleakage after thermocycling of 4 etch and rinse and 3 self-etch adhesives with and without a flowable composite lining
    Gueders, A. M.
    Charpentier, J. F.
    Albert, A. I.
    Geerts, S. O.
    OPERATIVE DENTISTRY, 2006, 31 (04) : 450 - 455