Interactive image guided surgery using frameless stereotactic system

被引:0
|
作者
Whang, CJ
Ra, YS
Lee, CH
Sohn, MJ
Lee, DJ
Kwun, BD
机构
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Interactive image guided surgery using frameless stereotactic system has been introduced in the neurosurgery for stereotactic localization without a standard frame. Viewing Wand system, one of clinically available frameless stereotactic system has been applied in 107 patients with various neurosurgical diseases in authors' hospital. To improve accuracy of this navigating system, we established the guideline of registration on the experimental basis of the phantom model. Though spatial accuracy of Viewing Wand system was acceptable in the clinical points of view, better accuracy can be expected when we use combined registration of external markers and random surface points as many as possible. Ninety-three percents of all cases were benefited by using the frameless stereotactic system. Especially the lesions located at eloquent area, subcortical, deep seated and intraventricular area can be approached safely by intraoperative navigation and real time feed back without damage of critical structures. Conclusively, image guided surgery using frameless stereotactic system is an useful tool in performing minimally invasive neurosurgery and locating anatomical structures and lesions to be removed.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [21] Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope - Commentary
    Alp, MS
    SURGICAL NEUROLOGY, 1998, 49 (03): : 288 - 289
  • [22] Fast-MICP for frameless image-guided surgery
    Lee, Jiann-Der
    Huang, Chung-Hsien
    Wang, Sheng-Ta
    Lin, Chung-Wei
    Lee, Shin-Tseng
    MEDICAL PHYSICS, 2010, 37 (09) : 4551 - 4559
  • [23] THE NEUROSTATION SYSTEM FOR IMAGE-GUIDED, FRAMELESS STEREOTAXY
    GERMANO, IM
    NEUROSURGERY, 1995, 37 (02) : 348 - 350
  • [24] Interactive image guided surgery (IIGS)
    Capanna, AH
    BIOMEDICAL SENSING, IMAGING, AND TRACKING TECHNOLOGIES II, 1997, 2976 : 184 - 189
  • [25] VARIOGUIDE: A NEW FRAMELESS IMAGE-GUIDED STEREOTACTIC SYSTEM-ACCURACY STUDY AND CLINICAL ASSESSMENT COMMENTS
    Bakay, Roy A. E.
    Gross, Robert E.
    Hall, Walter A.
    NEUROSURGERY, 2009, 64 (05) : 371 - 373
  • [26] Image localization for frameless stereotactic radiotherapy
    Meeks, SL
    Bova, FJ
    Wagner, TH
    Buatti, JM
    Friedman, WA
    Foote, KD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (05): : 1291 - 1299
  • [27] Stereotactic and image-guided surgery - Preface
    Batjer, HH
    Loftus, CM
    TECHNIQUES IN NEUROSURGERY, 2003, 8 (01): : 1 - 1
  • [28] The Impact of Imaging Frequency on Intrafraction Setup Corrections in Frameless Image Guided Stereotactic Radiosurgery
    Westerly, D.
    Stuhr, K.
    Altunbas, C.
    Diot, Q.
    Kavanagh, B.
    Miften, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] FRAMELESS IMAGE-GUIDED INTRACRANIAL STEREOTACTIC RADIOSURGERY: CLINICAL OUTCOMES FOR BRAIN METASTASES
    Breneman, John C.
    Steinmetz, Ryan
    Smith, Aaron
    Lamba, Michael
    Warnick, Ronald E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 702 - 706
  • [30] Image-guided, frameless stereotactic sectioning of the corpus callosum in children with intractable epilepsy
    Hodaie, M
    Musharbash, A
    Otsubo, H
    Snead, OC
    Chitoku, S
    Ochi, A
    Holowka, S
    Hoffman, HJ
    Rutka, JT
    PEDIATRIC NEUROSURGERY, 2001, 34 (06) : 286 - 294