Magnetic resonance imaging with the Digisonic SP Neurelec cochlear implant

被引:26
|
作者
Vincent, C. [1 ]
Ruzza, I. [1 ]
Vaneecloo, F. M. [1 ]
Dubrulle, F. [2 ]
机构
[1] CHRU, Otol & Neurotol Dept, Hop Salengro, F-59037 Lille, France
[2] CHRU, Dept Radiol, F-59037 Lille, France
关键词
cochlear implant; MRI; radiology; deafness;
D O I
10.1007/s00405-007-0576-6
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The goal of this study was to evaluate the MR compatibility of the Neurelec Digisonic SP cochlear implant by performing in vitro and in vivo tests. All tests were performed on 1.5 T machine. Torque and force were measured to observe a potential displacement of the internal receiver. Demagnetisation of the internal magnet was monitored inside the MRI scanner and outside the MRI scanner (in the MRI room). Potential-induced voltage on electrodes was measured in vitro, performing the usual MR sequences. Heating around the internal receiver was measured after the same MR sequences. Following in vitro tests, in vivo MR imaging (brain and posterior fossa MRI) was performed to evaluate the induced signal void and geometrical distortion. In vivo test was performed with one volunteer who had a cochlear implant device fixed to the surface of the skin with a bandage. All the in vitro tests were in compliance with standard EN 45502-2-3 relating to Cochlear Implants. In vivo MRI scans demonstrated an image distortion for spin echo sequences of 7 cm maximum around the internal magnet. Magnetic resonance imaging with the Neurelec Digisonic SP cochlear implant is possible with no measurable adverse effects for either the patient or the device. Image artefact around the internal magnet, however, is unavoidable.
引用
收藏
页码:1043 / 1046
页数:4
相关论文
共 50 条
  • [31] Reversing the polarity of a cochlear implant magnet after magnetic resonance imaging
    Jeon, Ju Hyun
    Bae, Mi Ran
    Chang, Jae Won
    Choi, Jae Young
    [J]. AURIS NASUS LARYNX, 2012, 39 (04) : 415 - 417
  • [32] The reversed internal magnet of cochlear implant after magnetic resonance imaging
    Kong, Soo-Keun
    Oh, Se-Joon
    Lee, Il-Woo
    Goh, Eui-Kyung
    [J]. AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2014, 35 (02) : 239 - 241
  • [33] SPEECH CODING STRATEGIES OF THE DIGISONIC FULLY DIGITIZED COCHLEAR IMPLANT
    CHOUARD, CH
    OUAYOUN, M
    MEYER, B
    FUGAIN, C
    [J]. ACTA OTO-LARYNGOLOGICA, 1995, 115 (02) : 264 - 268
  • [34] THE FRENCH MULTICHANNEL COCHLEAR IMPLANT DIGISONIC - CLINICAL-RESULTS
    CHOUARD, CH
    [J]. BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 1994, 178 (02): : 161 - 175
  • [35] Adverse Events and Discomfort During Magnetic Resonance Imaging in Cochlear Implant Recipients
    Kim, Bo Gyung
    Kim, Jin Won
    Park, Jeong Jin
    Kim, Sung Huhn
    Kim, Hee Nam
    Choi, Jae Young
    [J]. JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2015, 141 (01) : 45 - 52
  • [36] Magnetic Resonance Imaging Artifacts and Cochlear Implant Positioning at 1.5 T In Vivo
    Schroeer, Dirk
    Grupe, Gloria
    Rademacher, Grit
    Mutze, Sven
    Ernst, Arneborg
    Seidl, Rainer
    Mittmann, Philipp
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [37] Value of Routine Magnetic Resonance Imaging for the Preoperative Assessment of Cochlear Implant Candidates
    Alzhrani, Farid
    Babkour, Alaa
    Al-Muhawas, Fida
    Alsanosi, Abdulrahman
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (12)
  • [38] Adverse events in pediatric cochlear implant patients undergoing magnetic resonance imaging
    Gallant, Sara C.
    Danehy, Amy R.
    Licameli, Greg R.
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2021, 140
  • [39] Perception in noise with the Digisonic SP cochlear implant: Clinical trial of Saphyr processor's upgraded signal processing
    Bergeron, F.
    Hotton, M.
    [J]. EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2016, 133 : S4 - S6
  • [40] Digisonic® cochlear implant signal processing for speech intelligibility improvement in noise
    Wable, J
    Gallego, S
    Chouard, CH
    Meyer, B
    [J]. COCHLEAR IMPLANTS - AN UPDATE, 2002, : 159 - 164