Magnetic resonance imaging with the Digisonic SP Neurelec cochlear implant

被引:26
|
作者
Vincent, C. [1 ]
Ruzza, I. [1 ]
Vaneecloo, F. M. [1 ]
Dubrulle, F. [2 ]
机构
[1] CHRU, Otol & Neurotol Dept, Hop Salengro, F-59037 Lille, France
[2] CHRU, Dept Radiol, F-59037 Lille, France
关键词
cochlear implant; MRI; radiology; deafness;
D O I
10.1007/s00405-007-0576-6
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The goal of this study was to evaluate the MR compatibility of the Neurelec Digisonic SP cochlear implant by performing in vitro and in vivo tests. All tests were performed on 1.5 T machine. Torque and force were measured to observe a potential displacement of the internal receiver. Demagnetisation of the internal magnet was monitored inside the MRI scanner and outside the MRI scanner (in the MRI room). Potential-induced voltage on electrodes was measured in vitro, performing the usual MR sequences. Heating around the internal receiver was measured after the same MR sequences. Following in vitro tests, in vivo MR imaging (brain and posterior fossa MRI) was performed to evaluate the induced signal void and geometrical distortion. In vivo test was performed with one volunteer who had a cochlear implant device fixed to the surface of the skin with a bandage. All the in vitro tests were in compliance with standard EN 45502-2-3 relating to Cochlear Implants. In vivo MRI scans demonstrated an image distortion for spin echo sequences of 7 cm maximum around the internal magnet. Magnetic resonance imaging with the Neurelec Digisonic SP cochlear implant is possible with no measurable adverse effects for either the patient or the device. Image artefact around the internal magnet, however, is unavoidable.
引用
收藏
页码:1043 / 1046
页数:4
相关论文
共 50 条
  • [1] Magnetic resonance imaging with the Digisonic SP Neurelec cochlear implant
    C. Vincent
    I. Ruzza
    F. M. Vaneecloo
    F. Dubrulle
    [J]. European Archives of Oto-Rhino-Laryngology, 2008, 265 : 1043 - 1046
  • [2] Multicenter evaluation of Neurelec Digisonic® SP cochlear implant reliability
    Luminiţa Rădulescu
    Sebastian Cozma
    Casimir Niemczyk
    Nicolas Guevara
    Ivan Gahide
    John Economides
    Jean-Pierre Lavieille
    Renaud Meller
    Jean-Pierre Bébéar
    Emilien Radafy
    Philippe Bordure
    Djamel Djennaoui
    Eric Truy
    [J]. European Archives of Oto-Rhino-Laryngology, 2013, 270 : 1507 - 1512
  • [3] Multicenter evaluation of Neurelec Digisonic® SP cochlear implant reliability
    Radulescu, Luminita
    Cozma, Sebastian
    Niemczyk, Casimir
    Guevara, Nicolas
    Gahide, Ivan
    Economides, John
    Lavieille, Jean-Pierre
    Meller, Renaud
    Bebear, Jean-Pierre
    Radafy, Emilien
    Bordure, Philippe
    Djennaoui, Djamel
    Truy, Eric
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (04) : 1507 - 1512
  • [4] Minimally invasive pocket technique for the implantation of Neurelec Digisonic SP cochlear implant
    Vanlommel, Martine
    Lipski, Samuel
    Dolhen, Pierre
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2014, 271 (05) : 913 - 918
  • [5] Minimally invasive pocket technique for the implantation of Neurelec Digisonic SP cochlear implant
    Martine Vanlommel
    Samuel Lipski
    Pierre Dolhen
    [J]. European Archives of Oto-Rhino-Laryngology, 2014, 271 : 913 - 918
  • [6] Speech Performance and Sound Localization Abilities in Neurelec Digisonic® SP Binaural Cochlear Implant Users
    Verhaert, Nicolas
    Lazard, Diane S.
    Gnansia, Dan
    Bebear, Jean-Pierre
    Romanet, Philippe
    Meyer, Bernard
    Pean, Vincent
    Mollard, Dominique
    Truy, Eric
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2012, 17 (04) : 256 - 266
  • [7] Short-term results of Neurelec Digisonic SP cochlear implantation in prelingually deafened children
    Ozgul Akin Senkal
    Evren Hizal
    Haluk Yavuz
    Ismail Yilmaz
    Levent Naci Ozluoglu
    [J]. European Archives of Oto-Rhino-Laryngology, 2014, 271 : 1415 - 1422
  • [8] Surgical experience with two generations of digisonic cochlear implants (Neurelec)
    Mom, T.
    Akkari, M.
    Bascoul, A.
    Gilain, L.
    Avan, P.
    [J]. 10TH EUROPEAN SYMPOSIUM ON PAEDIATRIC COCHLEAR IMPLANTATION, 2011, : 97 - 103
  • [9] Comparison between Bilateral Cochlear Implants and Neurelec Digisonic® SP Binaural Cochlear Implant: Speech Perception, Sound Localization and Patient Self-Assessment
    Bonnard, Damien
    Lautissier, Sylvie
    Bosset-Audoit, Amelie
    Coriat, Geraldine
    Beraha, Max
    Maunoury, Antoine
    Martel, Jacques
    Darrouzet, Vincent
    Bebear, Jean-Pierre
    Dauman, Rene
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2013, 18 (03) : 171 - 183
  • [10] Short-term results of Neurelec Digisonic SP cochlear implantation in prelingually deafened children
    Senkal, Ozgul Akin
    Hizal, Evren
    Yavuz, Haluk
    Yilmaz, Ismail
    Ozluoglu, Levent Naci
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2014, 271 (06) : 1415 - 1422