Radio frequency measurements and tuning of the China Material Irradiation Facility RFQ

被引:9
|
作者
Li, Chenxing [1 ,2 ,3 ]
He, Yuan [1 ]
Wang, Fengfeng [1 ]
Yu, Peiyan [1 ,3 ]
Yang, Lei [1 ,3 ]
Li, Chunlong [1 ]
Wang, Wenbin [1 ]
Xu, Xianbo [1 ]
Shi, Longbo [1 ]
Ma, Wei [1 ,3 ]
Sun, Liepeng [1 ]
Lu, Liang [1 ]
Wang, Zhijun [1 ]
Shi, Aimin [1 ]
Wang, Tieshan [2 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China
[2] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Gansu, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Bead-pull measurement; RFQ tuning; Multi-port coupling; Q value measurement;
D O I
10.1016/j.nima.2018.02.047
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The full assembly and alignment of the China Material Irradiation Facility RFQ have been completed. Before the completion, the assembly and braze of single segments had been done. Radio frequency measurements of each module with dummy extension undercuts were performed before and after braze. The results reveal that there is no unexpected deformation after braze. After the full assembly, RF measurements and tuning have been performed in order to compensate the errors originated from the fabrication, braze and assembly. The impact of these errors on the field distribution is depressed to a level that is restricted by beam dynamics simulation. In this paper, the procedure of radio frequency measurement and tuning will be expatiated and the ultimate RF parameters of the cavity after tuning will be presented.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 50 条
  • [31] RF tuning and beam commissioning of CW RFQ for China-ADS Injector-I
    Hua Shi
    Huafu Ouyang
    Shengchang Wang
    Ningchuang Zhou
    Gang Wu
    Nuclear Science and Techniques, 2018, 29
  • [32] RF tuning and beam commissioning of CW RFQ for China-ADS Injector-I
    Shi, Hua
    Ouyang, Huafu
    Wang, Shengchang
    Zhou, Ningchuang
    Wu, Gang
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (10)
  • [33] RF tuning and beam commissioning of CW RFQ for China-ADS Injector-I
    Hua Shi
    Huafu Ouyang
    Shengchang Wang
    Ningchuang Zhou
    Gang Wu
    Nuclear Science and Techniques, 2018, 29 (10) : 21 - 29
  • [34] Precise tuning technique of frequency conversion crystals of SG facility
    Zhang Fan
    Zhong Wei
    Jia Huai Ting
    Wang YuanCheng
    Guo HuaiWen
    Deng XueWei
    Zhou Wei
    XX INTERNATIONAL SYMPOSIUM ON HIGH-POWER LASER SYSTEMS AND APPLICATIONS 2014, 2015, 9255
  • [35] Design Optimization of Radio Frequency Discrete Tuning Varactors
    Mendes, Luis
    Solteiro Pires, Eduardo J.
    de Moura Oliveira, Paulo B.
    Tenreiro Machado, Jose A.
    Fonseca Ferreira, Nuno M.
    Vaz, Joao Caldinhas
    Rosario, Maria J.
    APPLICATIONS OF EVOLUTIONARY COMPUTING, PROCEEDINGS, 2009, 5484 : 343 - +
  • [36] DESIGN STUDY OF FUSION MATERIAL IRRADIATION TEST FACILITY IN JAPAN
    MIYAHARA, A
    MIYAHARA, K
    KAWASAKI, S
    YAMAMOTO, K
    NISHIZAWA, H
    JOURNAL OF NUCLEAR MATERIALS, 1986, 141 : 1003 - 1010
  • [37] Neutronics and activation characteristics of the international fusion material irradiation facility
    Simakov, SP
    Fischer, U
    Möslang, A
    Vladimirov, P
    Wasastjerna, F
    Wilson, PPH
    FUSION ENGINEERING AND DESIGN, 2005, 75-79 : 813 - 817
  • [38] Protection of Radio Astronomy Frequency in China
    Wu Shengyin Beijing Astronomical Observatory The Chinese Academy of Sciences Beijing China
    云南天文台台刊, 1999, (S1) : 90 - 93
  • [39] DOSIMETRY TECHNIQUES FOR MEASUREMENTS IN CO-60 IRRADIATION FACILITY
    ABDELREHIM, F
    ABDELFATTAH, AA
    SOLIMAN, FAS
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1994, 19 (2A): : 143 - 152
  • [40] Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor
    Colautti, P.