Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea

被引:3
|
作者
Zheng, Zhenzhen [1 ]
Zhang, Yitao [2 ]
Chen, Mingdi [1 ]
Chen, Xiaojuan [3 ]
Li, Chunhe [4 ]
Wang, Chaoyu [5 ]
Zhu, Jinru [1 ]
Lin, Junyan [6 ]
Ou, Xudong [6 ]
Zou, Zhihong [6 ]
Wang, Zhiwei [6 ]
Deng, Junzhong [1 ]
Chen, Riken [6 ]
机构
[1] Guangdong Med Univ, Affiliated Hosp 2, Zhanjiang, Peoples R China
[2] Yangjiang Hosp Tradit Chinese Med, Yangjiang, Peoples R China
[3] Jiaying Univ, Med Coll, Meizhou, Peoples R China
[4] Guangzhou Univ Chinese Med, Affiliated Hosp 1, Guangzhou, Peoples R China
[5] Taishan Hosp Tradit Chinese Med, Jiangmen, Peoples R China
[6] Guangzhou Med Univ, State Key Lab Resp Dis, Natl Clin Res Ctr Resp Dis, Guangzhou Inst Resp Hlth,Affiliated Hosp 1, Guangzhou, Peoples R China
关键词
obstructive sleep apnea; Epworth Sleepiness Scale; STOP-Bang questionnaire; diagnostic; polysomnography; EXCESSIVE DAYTIME SLEEPINESS; RISK-FACTOR; HEALTH; IMPACT; OSA; MORTALITY; STROKE;
D O I
10.3389/fpubh.2022.950585
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
ObjectiveThis paper evaluates the application value of the STOP-Bang questionnaire combined with the Epworth Sleepiness Scale (ESS) in screening for obstructive sleep apnea (OSA) in the population. MethodThousand-six hundred seventy-one patients with suspected OSA who visited the Sleep Medicine Center of the First Affiliated Hospital of Guangzhou Medical University from August 2017 to August 2020 were monitored by overnight polysomnography (PSG) after completing the ESS scale and STOP-Bang questionnaire. The sensitivity, specificity, positive predictive value, negative predictive value and receiver operating characteristic (ROC) curves of the two scales were calculated, and the accuracy in predicting OSA of the STOP-Bang questionnaire combined with ESS was analyzed. ResultsWith Apnea Hypopnea Index (AHI) cutoffs of >= 5, >= 15 and >= 30 events/h, the areas under the ROC curve scored by STOP-Bang were 0.724, 0.703 and 0.712, and those of ESS were 0.632, 0.634 and 0.695; the diagnostic odds ratio (DOR) values of STOP-Bang for OSA, moderate to severe OSA, and severe OSA were 3.349, 2.651 and 3.189, and those of ESS were 2.665, 2.279 and 3.289. The STOP-Bang score of three was used as the cut-off point for OSA diagnosis with higher sensitivity and lower specificity, while ESS had higher specificity. STOP-Bang (>= 3) combined with ESS significantly improved its specificity for predicting OSA. ConclusionThe STOP-Bang questionnaire is a simple and effective new tool for screening patients for OSA, while a STOP-Bang score of >= 3 combined with ESS can further improve its specificity. Thus, we suggest further screening with ESS after a STOP-Bang score of >= 3 in suspected patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Epworth Sleepiness Scale and STOP-Bang questionnaire as screening tools for obstructive sleep apnea
    Pimentel, C.
    Santos, C.
    Feijo, S.
    [J]. JOURNAL OF SLEEP RESEARCH, 2020, 29 : 219 - 219
  • [2] Comparison of Berlin Questionnaire, STOP-Bang, and Epworth Sleepiness Scale for Diagnosing Obstructive Sleep Apnea in Persian Patients
    Amra, Babak
    Javani, Maedeh
    Soltaninejad, Forogh
    Penzel, Thomas
    Fietze, Ingo
    Schoebel, Christoph
    Farajzadegan, Ziba
    [J]. INTERNATIONAL JOURNAL OF PREVENTIVE MEDICINE, 2018, 9
  • [3] STOP-Bang questionnaire is superior to Epworth sleepiness scales, Berlin questionnaire, and STOP questionnaire in screening obstructive sleep apnea hypopnea syndrome patients
    Luo Jinmei
    Huang Rong
    Zhong Xu
    Xiao Yi
    Zhou Jiong
    [J]. CHINESE MEDICAL JOURNAL, 2014, 127 (17) : 3065 - 3070
  • [4] Diagnostic Accuracy of the STOP-BANG Questionnaire and the EPWORTH SLEEPINESS SCALE in Detecting Obstructive Sleep Apnea in Bariatric Surgery Candidates
    Hassan, S.
    Mubarik, A.
    Burney, W.
    Khan, S.
    Qasim, M.
    Basit, M.
    Haq, F.
    Rahaghi, F. N.
    Muddassir, S.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [5] Comparison of Stop Bang Questionnaire and Epworth Sleepiness Scale for Screening of Obstructive Sleep Apnoea
    Talatam, Ram Phanindra
    Suriyan, Subramanian
    Nagesh, Nalini Jayanthi
    Seema, S.
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2020, 9 (37): : 2700 - 2703
  • [6] Obstructive sleep apnea screening in different age groups: performance of the Berlin, STOP-Bang questionnaires and Epworth Sleepiness Scale
    Silva, Daniel Villela e
    Alves, Davi da Silveira Barroso
    Nobrega, Mariana da Rocha Rodrigues
    Ribeiro, Felipe Braga Coelho Gomes
    Franco, Leandro Yukio Yatabe
    da Silva, Isadora Rodrigues
    Joffily, Lucia
    da Rocha, Maira
    Godoy, Paulo Henrique
    [J]. BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2023, 89 (04)
  • [7] Validation of the nosas score for obstructive sleep apnea screening in the Greek population and comparison with Epworth Sleepiness Scale, Berlin- and the STOP-Bang questionnaire
    Georgakopoulou, V. E.
    Pantazis, N.
    Tsiafaki, X.
    Anevlavis, S.
    Nena, E.
    Amfilochiou, A.
    Steiropoulos, P.
    [J]. JOURNAL OF SLEEP RESEARCH, 2022, 31
  • [8] A Screening Tool of Obstructive Sleep Apnea STOP-Bang Questionnaire
    Yang, Yiliang
    Chung, Frances
    [J]. SLEEP MEDICINE CLINICS, 2013, 8 (01) : 65 - +
  • [9] USE OF THE EPWORTH SLEEPINESS SCALE, THE NOSAS, AND THE STOP-BANG QUESTIONNAIRE TO IDENTIFY PATIENTS WITH MODERATE-TO-SEVERE OBSTRUCTIVE SLEEP APNEA
    Yin, S.
    Xu, H.
    Zhang, C.
    Zou, J.
    Guan, J.
    Yi, H.
    [J]. SLEEP, 2020, 43 : A230 - A230
  • [10] Screening Ability of STOP-Bang Questionnaire for Obstructive Sleep Apnea
    Kawada, Tomoyuki
    [J]. ANESTHESIA AND ANALGESIA, 2019, 128 (03): : E48 - E49