Comparison of 3D BOLD functional MRI with spiral acquisition at 1.5 and 4.0 T

被引:36
|
作者
Yang, YH [1 ]
Wen, H
Mattay, VS
Balaban, RS
Frank, JA
Duyn, JP
机构
[1] NIH, OIR, Lab Diagnost Radiol Res, Bethesda, MD 20892 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[3] NIMH, Clin Brain Disorders Branch, NIH, Bethesda, MD 20892 USA
关键词
functional MRI; spiral scan; high field;
D O I
10.1006/nimg.1998.0422
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In order to investigate the merit of high field strength for BOLD-contrast-based functional magnetic resonance imaging (fMRI) studies, multishot gradient echo fMRI experiments during motor cortex activation were performed on 1.5- and 4.0-T scanners with equivalent hardware, on the same volunteers, in these studies, artifactual vascular enhancement related to inflow effects was minimized, and large brain areas were covered by using a 3D scan technique. Temporal signal stability was optimized by using spiral readout gradients. The sensitivity for detection of activated regions was assessed by measuring the number of "activated voxels" and their average t score in predefined regions of interest. When comparing fMRI experiments with the same total scan time, performed on six subjects, and with acquisition parameters optimized for each field strength separately the 4.0-T scanner proved to give superior results, with a 70% greater number of activated voxels and a 20% higher average t score for the activated voxels.
引用
收藏
页码:446 / 451
页数:6
相关论文
共 50 条
  • [1] Fast 3D functional MR imaging at 1.5 T with spiral acquisition
    Yang, Y
    Duyn, JH
    Glover, GH
    VanGelderen, P
    Mattay, VS
    Frank, JA
    [J]. RADIOLOGY, 1996, 201 : 446 - 446
  • [2] Fast 3D functional magnetic resonance imaging at 1.5 T with spiral acquisition
    Yang, YH
    Glover, GH
    vanGelderen, P
    Mattay, VS
    Santha, AKS
    Sexton, RH
    Ramsey, NF
    Moonen, CTW
    Weinberger, DR
    Frank, JA
    Duyn, JH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 620 - 626
  • [3] Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer functional MRI at 7 T
    Beckett, Alexander J. S.
    Dadakova, Tetiana
    Townsend, Jennifer
    Huber, Laurentius
    Park, Suhyung
    Feinberg, David A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3128 - 3145
  • [4] Functional bold MRI: advantages of the 3 T vs. the 1.5 T
    Garcia-Eulate, Reyes
    Garcia-Garcia, David
    Dominguez, Pablo D.
    Noguera, Jose J.
    De Luis, Esther
    Rodriguez-Oroz, Maria C.
    Zubieta, Jose L.
    [J]. CLINICAL IMAGING, 2011, 35 (03) : 236 - 241
  • [5] Comparison of spiral-in/out and spiral-out BOLD fMRI at 1.5 and 3T
    Preston, AR
    Thomason, ME
    Ochsner, KN
    Cooper, JC
    Glover, GH
    [J]. NEUROIMAGE, 2004, 21 (01) : 291 - 301
  • [6] Time-Resolved 3D Pulmonary Perfusion MRI Comparison of Different k-Space Acquisition Strategies at 1.5 and 3 T
    Attenberger, Ulrike I.
    Ingrisch, Michael
    Dietrich, Olaf
    Herrmann, Karin
    Nikolaou, Konstantni
    Reiser, Maximilian F.
    Schoenberg, Stefan
    Fink, Christian
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 525 - 531
  • [7] Double Spiral Array Coil Design for Enhanced 3D Parallel MRI at 1.5 Tesla
    Mueller, Matthias F.
    Blaimer, Martin
    Breuer, Felix
    Lanz, Titus
    Webb, Andrew
    Griswold, Mark
    Jakob, Peter
    [J]. CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (02) : 67 - 79
  • [8] Comparison of functional MR-venography and EPI BOLD fMRI at 1.5 T
    Baudendistel, K
    Reichenbach, JR
    Metzner, R
    Schroeder, J
    Schad, LR
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (08) : 989 - 991
  • [9] Submillimeter balanced SSFP BOLD-functional MRI accelerated with 3D stack-of-spirals at 9.4 T
    Valsala, Praveen Iyyappan
    Veldmann, Marten
    Bosch, Dario
    Scheffler, Klaus
    Ehses, Philipp
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (01) : 186 - 201
  • [10] 3D T1-weighted MRI of the human knee at 1.5T
    Borthakur, A
    Regatte, RR
    Akella, SV
    Wheaton, AJ
    Kneeland, JB
    Reddy, R
    [J]. RADIOLOGY, 2002, 225 : 329 - 329