Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection

被引:78
|
作者
Qin, Yong-Lin [1 ]
Deng, Gang [1 ]
Li, Tian-Xiao [3 ]
Jing, Rui-Wei [2 ]
Teng, Gao-Jun [1 ]
机构
[1] Southeast Univ, Zhongda Hosp, Sch Med, Dept Intervent Radiol & Vasc Surg, Nanjing 210009, Peoples R China
[2] Southeast Univ, Dept Stat, Sch Publ Hlth, Nanjing 210009, Peoples R China
[3] Henan Prov Peoples Hosp, Dept Intervent Radiol, Zhengzhou, Peoples R China
关键词
COMPLICATED ACUTE; DESCENDING AORTA; REPAIR; ECHOCARDIOGRAPHY; PREDICTOR; PROGNOSIS; DIAMETER; TEARS;
D O I
10.1016/j.jvs.2012.04.019
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study evaluated the risk factors of incomplete thrombosis in the false lumen after thoracic endovascular aortic repair (TEVAR) in patients with extensive acute type B aortic dissection. Methods: This was a retrospective study at Zhongda Hospital and Henan Provincial People's Hospital, China. Between January 2005 and May 2008, patients with acute type B dissection who underwent TEVAR at two centers were reviewed and 124 who met the following criteria were included in this study: (1) dissection involving the aorta below the level of the celiac artery, (2) completely patent false lumen at the time of intervention, and (3) complete initial diagnostic computed tomography (CT) scans and all follow-up CT scans available. Exclusion criteria were (1) aortic dissection secondary to trauma, (2) intramural hematoma, and (3) Marfan patients. The main outcome measures were demographics, comorbidity profiles, technical details of procedures, anatomic characteristics of dissection, and false lumen status of thrombosis during follow-up. Ordinal regression analysis was performed with variables that reached P < .20 on univariate analysis to investigate independent risk factors of incomplete thrombosis in the false lumen. Results: Univariate analysis showed that the age at TEVAR, hypertension, maximum diameter of the abdominal aorta and false lumen at the abdominal level, re-entry tears, and visceral branches that arose partially or totally from the false lumen had a P < .20. Further analysis with an ordinal regression model showed that the visceral branches that arose partially or totally from the false lumen (odds ratio [OR], 10.054; P < .001), re-entry tears (OR, 30.661; P < .001), and maximum diameter of the false lumen on the abdominal aorta (OR, 1.265; P = .004) were the significant risk factors of incomplete thrombosis in the false lumen after TEVAR. Conclusions: Visceral branches that arose partially or totally from the false lumen, re-entry tears, and maximum diameter of the false lumen on the abdominal aorta were the risk factors of incomplete thrombosis in the false lumen after TEVAR in extensive acute type B dissection. (J Vasc Surg 2012;56:1232-8.)
引用
收藏
页码:1232 / 1238
页数:7
相关论文
共 50 条
  • [31] Endovascular treatment of acute type B aortic dissection
    Taylor, PR
    Bell, RE
    Reidy, JF
    ACTA CHIRURGICA BELGICA, 2004, 104 (05) : 513 - 518
  • [32] False lumen size: a powerful predictor of acute type B aortic dissection
    Nature Clinical Practice Cardiovascular Medicine, 2009, 6 (1): : 4 - 5
  • [33] Endovascular graft deployment in the false lumen of type B dissection
    Follis, Fabrizio
    Filippone, Gianfranco
    Stabile, Amerigo
    Montalbano, Giuseppe
    Floriano, Maria
    Finazzo, Mario
    Follis, Marco
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (04) : 597 - 599
  • [34] Role of initial medical treatment and effectiveness of thoracic endovascular aortic repair for acute type A aortic dissection with thrombosed false lumen
    Masada, Kenta
    Shinzato, Kento
    Koizumi, Shigeki
    Yokawa, Koki
    Kasai, Mio
    Inoue, Yosuke
    Seike, Yoshimasa
    Sasaki, Hiroaki
    Matsuda, Hitoshi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 63 (05)
  • [35] False Lumen Embolization to Treat Disseminated Intravascular Coagulation After Thoracic Endovascular Aortic Repair of Type B Aortic Dissection
    Mendes, Bernardo C.
    Oderich, Gustavo S.
    Erben, Young
    Reed, Nanette R.
    Pruthi, Rajiv K.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (06) : 938 - 941
  • [36] A misplaced guide wire in the false lumen during endovascular repair of a type B aortic dissection
    Fayad, Ashraf
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (11): : 947 - 948
  • [37] A misplaced guide wire in the false lumen during endovascular repair of a type B aortic dissection
    Ashraf Fayad
    Canadian Journal of Anesthesia, 2007, 54 : 947 - 948
  • [38] Partial false lumen thrombosis as a predictor of mortality in patients with type B acute aortic dissection: Insights from the international registry of acute aortic dissection (IRAD)
    Tsai, TT
    Evangelista, A
    Nienaber, C
    Myrmel, T
    Sechtem, U
    Cooper, JV
    Suzuki, T
    Fattori, R
    Distante, A
    Sundt, T
    Beckman, J
    Januzzi, J
    Isselbacher, E
    Eagle, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 315A - 315A
  • [39] A Successful Endovascular Technique for Complete False Lumen Thrombosis in Chronic Abdominal Aortic Dissection
    Hiruma, Hiromitsu
    Ogawa, Yukihisa
    Chiba, Kiyoshi
    Maruhashi, Takaaki
    Kotoku, Akiyuki
    Mimura, Hidefumi
    Miyairi, Takeshi
    Nishimaki, Hiroshi
    ANNALS OF VASCULAR DISEASES, 2021, 14 (01) : 75 - 78
  • [40] Exploring hemodynamic mechanisms and re-intervention strategies for partial false lumen thrombosis in Stanford type B aortic dissection after thoracic aortic endovascular repair
    Wang, Jian
    Chen, Bing
    Gao, Fan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 417