Temperature-independent refractometer based on a tapered photonic crystal fiber interferometer

被引:15
|
作者
Ni, Kai [1 ,2 ]
Chan, Chi Chiu [2 ]
Dong, Xinyong [1 ,2 ]
Poh, C. L. [2 ]
Li, Tao [1 ,2 ]
机构
[1] China Jiliang Univ, Inst Optoeletron Technol, Hangzhou 310027, Zhejiang, Peoples R China
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, Singapore 637457, Singapore
基金
中国国家自然科学基金;
关键词
Refractometer; Temperature-independent; Photonic crystal fiber interferometer; Fiber tapers; SENSITIVITY; SENSOR;
D O I
10.1016/j.optcom.2012.11.037
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A temperature-independent refractometer by using a tapered photonic crystal fiber (PCF) based Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. It is fabricated by sandwiching a tapered PCF of 29 mm long between two standard single mode fibers (SMFs) with the fully collapsed air holes of the PCF in the fusion splicing region. It has been found that tapering the PCF greatly enhances the sensitivity of the refractometer. A maximum sensitivity of 1529 nm/RIU (refractive index unit) is achieved within the range from 1.3355 to 1.413. The refractometer is nearly temperature-insensitive due to the ultra low temperature dependence of the used. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 241
页数:4
相关论文
共 50 条
  • [31] Hydrogen sulfide gas sensor based on graphene-coated tapered photonic crystal fiber interferometer
    Feng, Xu
    Feng, Wenlin
    Tao, Chuanyi
    Deng, Dashen
    Qin, Xiang
    Chen, Rong
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 540 - 545
  • [32] Experimental research of curvature sensor based on tapered photonic crystal fiber Mach-Zehnder interferometer
    School of Information Science and Engineering, Yanshan University, Qinhuangdao
    Hebei
    066004, China
    不详
    Hebei
    066004, China
    Guangxue Xuebao, 5
  • [33] Temperature-independent strain sensor based on a core-offset multi-mode fiber interferometer
    Dong, Bo
    Wei, Li
    Zhou, Da-Peng
    Liu, Wing-Ki
    Lit, John W. Y.
    FIBER OPTIC SENSORS AND APPLICATIONS VI, 2009, 7316
  • [34] Refractive index sensing based on photonic crystal fiber interferometer structure with up-tapered joints
    Zhao, Yong
    Li, Xue-gang
    Cai, Lu
    Yang, Yang
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 406 - 410
  • [35] Tapered Photonic Crystal Fiber Based Mach-Zehnder Interferometer for Enhanced Refractive Index Sensing
    Ahmed, Farid
    Jun, Martin B. G.
    2015 IEEE SENSORS, 2015, : 1355 - 1358
  • [36] Fiber Sagnac interferometer based on a liquid-filled photonic crystal fiber for temperature sensing
    Liu, Qiang
    Li, Shu-Guang
    Shi, Min
    OPTICS COMMUNICATIONS, 2016, 381 : 1 - 6
  • [37] Photonic crystal fiber half-taper probe based refractometer
    Wang, Pengfei
    Ding, Ming
    Bo, Lin
    Guan, Chunying
    Semenova, Yuliya
    Sun, Weimin
    Yuan, Libo
    Brambilla, Gilberto
    Farrell, Gerald
    OPTICS LETTERS, 2014, 39 (07) : 2076 - 2079
  • [38] Optical fiber interferometer for temperature-independent refractive index measuring over a broad range
    Flores-Bravo, J. A.
    Illarramendi, M. A.
    Zubia, Joseba
    Villatoro, Joel
    OPTICS AND LASER TECHNOLOGY, 2021, 139 (139):
  • [39] Miniature tapered photonic crystal fiber interferometer with enhanced sensitivity by acid microdroplets etching
    Qiu, Sun-jie
    Chen, Ye
    Kou, Jun-long
    Xu, Fei
    Lu, Yan-qing
    APPLIED OPTICS, 2011, 50 (22) : 4328 - 4332