Study of the Pollution Cleaning Technology on Water Systems of Floor Heating Central Air Conditioning with Environmental Materials

被引:0
|
作者
Hua Hongyan [1 ]
Zhang Zhen [1 ]
机构
[1] Zhengzhou Inst Aeronaut Ind Management, Zhengzhou, Peoples R China
关键词
central air conditioning; cleaning technology; environmental materials; water systems pollution;
D O I
10.4028/www.scientific.net/AMR.600.92
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Energy saving of floor heating air-conditioning system in buildings becomes a key and hot topic in energy saving area when the energy crisis puts the whole world in a seriously hard position. Cleaning water system of central air conditioning will reduce energy consumption, and improve the operating performance and efficiency. In this paper, pollution condition of water system is introduced, the necessity of cleaning water system is analyzed, and the technological process of the water system cleaning for an office building floor heating central air conditioning is discussed.
引用
收藏
页码:92 / 95
页数:4
相关论文
共 50 条
  • [1] Bath central heating and air conditioning systems Economic Analysis
    Yang, Jingang
    [J]. MATERIAL SCIENCE AND ADVANCED TECHNOLOGIES IN MANUFACTURING, 2014, 852 : 745 - 748
  • [2] Environmental impact and life cycle assessment of heating and air conditioning systems, a simplified case study
    Prek, M
    [J]. ENERGY AND BUILDINGS, 2004, 36 (10) : 1021 - 1027
  • [3] Application of Water Pump Proportionality Law to Heating and Air Conditioning Systems
    Fu, Yongzheng
    Zhou, Xiaobei
    Zhou, Hongdan
    [J]. ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3054 - +
  • [4] Criteria for the selection of control valves for central heating and air-conditioning systems
    Gottfried, Knabe
    [J]. HLH Dusseldorf, 1997, 48 (05): : 54 - 60
  • [5] An Analysis of Hygiene Status of Central Air Conditioning Ventilation Systems and the Cleaning Industry in China
    Lu Kai
    Zhao Xin
    Liao Yan
    Chen Yu
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL ACADEMIC CONFERENCE ON ENVIRONMENTAL AND OCCUPATIONAL MEDICINE, 2010, : 46 - 48
  • [6] Indoor air pollution by different heating systems: Coal burning, open fireplace and central heating
    Moriske, HJ
    Drews, M
    Ebert, G
    Menk, G
    Scheller, C
    Schondube, M
    Konieczny, L
    [J]. TOXICOLOGY LETTERS, 1996, 88 (1-3) : 349 - 354
  • [7] Optimizing the topologies of heating, ventilation, and air-conditioning water systems in supertall buildings: A pilot study
    Feng, Fan
    Fu, Yangyang
    Hou, Jin
    Xu, Peng
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (04) : 371 - 381
  • [8] Study of the Aeraulic Flows in a Building Including Heating and Air Conditioning Systems
    Laaroussi, N.
    Chihab, Y.
    Garoum, M.
    Benet, L-V.
    Lacroux, F.
    [J]. FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2015, 11 (04): : 354 - 365
  • [9] Study of the aeraulic flows in a building including heating and air conditioning systems
    Mohammed V University in Rabat, EST de Salé, Materials, Energy and Acoustics , Avenue Prince Héritier, BP. 227, Salé Medina, Morocco
    不详
    78180, France
    不详
    F-92084
    [J]. Fluid Dyn. Mater. Process., 4 (354-365):
  • [10] Analysis of energy saving technology for Central Air Conditioning water system operation
    Liu, Jingfeng
    Wang, Jun
    Li, Guangpeng
    [J]. INTERNATIONAL CONFERENCE ON MECHANICAL DESIGN AND SIMULATION (MDS 2022), 2022, 12261