Focus group analysis of hand-held radiation detector design

被引:2
|
作者
Savory, Paul [1 ]
Crowe, James V. [2 ]
Hallbeck, M. Susan [2 ]
机构
[1] Univ Nebraska, Dept Management, Lincoln, NE 68588 USA
[2] Univ Nebraska, Innovat Design & Ergon Anal Lab, Lincoln, NE 68588 USA
关键词
Focus group; First responder; Radiation detector; Product development; ANSI N42.34;
D O I
10.1016/j.ergon.2011.11.003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A focus group session is a useful tool for learning user expectations, preferences, and suggested enhancements during the design stage of a new product. This paper showcases the usefulness of using a mixed-method focus group study of first responders to examine the design of a hand-held radiation detector. The study used a survey and a semi-structured script that explored five main topics: difficulties of using radiation detection with respect to the equipment and environment; preferences for handle design; preferences for control design; preferences for screen, menu, and interface design, and instructional and maintenance issues. The focus group indicated a desire for fewer and bigger buttons to control the device, a desire for a san serif font type for the display, a request to minimize the use of abbreviations and symbols in the text display, having a color coding display bar to describe radiation levels, and a need for detailed maintenance procedures and processes. These results provide important feedback for planning the development and testing of a more ergonomic radiation detector. Relevance to industry: A hand-held radiation detector to test for fissionable materials is one of the essential tools used by first responders. This paper presents the results from a focus group of first responders exploring characteristics for a more ergonomic detector. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [21] Design and evaluation of an ergonomic hand-held scraper
    Sheu, FH
    Chang, CL
    [J]. ADVANCES IN OCCUPATIONAL ERGONOMICS AND SAFETY 1997, 1997, : 181 - 184
  • [22] Hand-Held Spectrophotometer Design for Textile Fabrics
    Bocekci, Veysel Gokhan
    Yildiz, Kazim
    [J]. 2ND INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND SMART MATERIALS (ICEESM 2017), 2017, 1884
  • [23] The Design of TPMS Hand-held Diagnostic Instrument
    Hou, Dongdong
    Hu, Dairong
    Guo, Kun
    [J]. SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS II, PTS 1 AND 2, 2014, 475-476 : 82 - 85
  • [24] Hand-held scanner: LLNL introduces portable rad detector
    [J]. Nuclear News, 2003, 46 (09):
  • [25] A systematic ergonomic approach for the analysis, design and evaluation of hand-held tools
    Strasser, Helmut
    [J]. ERGONOMICS FOR ALL: CELEBRATING PPCOE'S 20 YEARS OF EXCELLENCE, 2011, : 329 - 334
  • [26] Radiation effects on human operators of hand-held radios
    Skacan, L
    Malaric, K
    [J]. PROCEEDINGS ELMAR-2005, 2005, : 349 - 352
  • [27] Hand-held chemical analysis instruments - An overview of vapor detection and the state of the art in hand-held detectors
    Harden, CS
    [J]. ANALYTICAL CHEMISTRY ASSOCIATED WITH THE DESTRUCTION OF CHEMICAL WEAPONS, 1997, 13 : 289 - 302
  • [28] Hand-Held Device
    Hadas, Rachel
    [J]. HUDSON REVIEW, 2019, 71 (04): : 791 - 794
  • [29] Hand-held computers
    Busby, B
    [J]. HEALTH PHYSICS, 2001, 81 (04): : 365 - 365
  • [30] Hand-held computer
    不详
    [J]. GAS ENGINEERING & MANAGEMENT, 1998, 38 (06): : 27 - 27