Reduced Equivalent Static Wind Loads for Tall Buildings with Tuned Liquid Dampers

被引:3
|
作者
Ross, A. S. [1 ]
El Damatty, A. A. [1 ]
El Ansary, A. M. [1 ]
机构
[1] Univ Western Ontario, Dept Civil & Environm Engn, London, ON N6A 5B9, Canada
关键词
Tall buildings; Tuned liquid dampers; Sloshing motion; Vibration control; Damping; Serviceability; Wind tunnel Tests; SCREENS; TLD; EXCITATION; MODEL; TMD;
D O I
10.4028/www.scientific.net/AMM.226-228.1218
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The tuned liquid damper (TLD) is a proven and an increasingly popular auxiliary device for mitigating the dynamic effects induced by wind loading on tall buildings. As buildings become taller, lighter, and more flexible, there is a greater contribution from the dynamic component. The most reliable tool for assessing the dynamic component is wind tunnel testing. A boundary layer wind tunnel is capable of accurately calculating an equivalent static wind load (ESWL) acting on a building. The current study investigates the reduction in the ESWL of a lateral-torsional coupled building with a TLD system installed. The building is sensitive to torsion in the first two vibration modes. The current investigation uses three unique multi-modal TLD systems designed specifically for a lateral-torsional coupled building. The building ESWL is evaluated with the TLD systems using measurements from tests conducted at the Boundary Layer Wind Tunnel Laboratory at Western University.
引用
收藏
页码:1218 / 1227
页数:10
相关论文
共 50 条
  • [31] DYNAMIC TORNADIC WIND LOADS ON TALL BUILDINGS
    WEN, YK
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1975, 101 (NST1): : 169 - 185
  • [32] Effect of proximity on wind loads on tall buildings
    Ahuja, Ashok Kumar
    Raj, Ritu
    [J]. CONSTRUCTION MATERIALS AND STRUCTURES, 2014, : 1303 - 1309
  • [33] The practical effects of friction for tuned mass dampers installed in tall buildings
    Love, J. S.
    Haskett, T. C.
    [J]. ENGINEERING STRUCTURES, 2022, 265
  • [34] Wind-induced response and equivalent static wind load for base-isolated tall buildings
    Li, Zhihao
    Huang, Guoqing
    Zhou, Ying
    Yang, Qingshan
    Yang, Xudong
    [J]. Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2024, 54 (04): : 852 - 860
  • [35] Effects of tuned mass damper on correlation of wind-induced responses and combination coefficients of equivalent static wind loads of high-rise buildings
    Wang, Qinhua
    Li, Ziyi
    Garg, Ankit
    Hazra, Budhaditya
    Xie, Zhuangning
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (06):
  • [36] Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building
    Suthar, Sameer J.
    Jangid, Radhey Shyam
    [J]. INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (01)
  • [37] Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building
    Sameer J. Suthar
    Radhey Shyam Jangid
    [J]. Innovative Infrastructure Solutions, 2022, 7
  • [38] Equivalent static wind loads on high-rise buildings based on inversion method
    Huang, Dong-Mei
    Zhu, Le-Dong
    Ding, Quan-Shun
    Chen, Wei
    [J]. Gongcheng Lixue/Engineering Mechanics, 2012, 29 (01): : 99 - 105
  • [39] Across-Wind Equivalent Static Wind Loads and Responses of Super-High-Rise Buildings
    Quan, Yong
    Gu, Ming
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (12) : 2145 - 2155