Reduced Equivalent Static Wind Loads for Tall Buildings with Tuned Liquid Dampers

被引:3
|
作者
Ross, A. S. [1 ]
El Damatty, A. A. [1 ]
El Ansary, A. M. [1 ]
机构
[1] Univ Western Ontario, Dept Civil & Environm Engn, London, ON N6A 5B9, Canada
关键词
Tall buildings; Tuned liquid dampers; Sloshing motion; Vibration control; Damping; Serviceability; Wind tunnel Tests; SCREENS; TLD; EXCITATION; MODEL; TMD;
D O I
10.4028/www.scientific.net/AMM.226-228.1218
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The tuned liquid damper (TLD) is a proven and an increasingly popular auxiliary device for mitigating the dynamic effects induced by wind loading on tall buildings. As buildings become taller, lighter, and more flexible, there is a greater contribution from the dynamic component. The most reliable tool for assessing the dynamic component is wind tunnel testing. A boundary layer wind tunnel is capable of accurately calculating an equivalent static wind load (ESWL) acting on a building. The current study investigates the reduction in the ESWL of a lateral-torsional coupled building with a TLD system installed. The building is sensitive to torsion in the first two vibration modes. The current investigation uses three unique multi-modal TLD systems designed specifically for a lateral-torsional coupled building. The building ESWL is evaluated with the TLD systems using measurements from tests conducted at the Boundary Layer Wind Tunnel Laboratory at Western University.
引用
收藏
页码:1218 / 1227
页数:10
相关论文
共 50 条
  • [1] Alongwind static equivalent wind loads and responses of tall buildings. Part I: Unfavorable distributions of static equivalent wind loads
    Zhou, Y
    Gu, M
    Xiang, HF
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 79 (1-2) : 135 - 150
  • [2] Tunable Tuned Liquid Column Dampers with Multi Cells for Wind Vibration Control of Tall Buildings
    Kim, Dong-Ik
    Min, Kyung-Won
    Park, Ji-Hun
    Lee, Hye-Ri
    Kim, Jae-Keon
    Hwang, Kyu-Seok
    Gil, Yong-Sik
    [J]. SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2012, PTS 1 AND 2, 2012, 8345
  • [3] Wind load effects and equivalent static wind loads of tall buildings based on synchronous pressure measurements
    Huang, Guoqing
    Chen, Xinzhong
    [J]. ENGINEERING STRUCTURES, 2007, 29 (10) : 2641 - 2653
  • [4] EFFECT OF TUNED MASS DAMPERS ON WIND INDUCED RESPONSE OF TALL BUILDINGS
    TANAKA, H
    MAK, CY
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1983, 14 (1-3) : 357 - 368
  • [5] EQUIVALENT STATIC WIND LOADS FOR TALL BUILDING DESIGN
    SIMIU, E
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (04): : 719 - 725
  • [6] EQUIVALENT STATIC WIND LOADS FOR TALL BUILDING DESIGN
    SIMIU, E
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1976, 102 (04): : 719 - 737
  • [7] EQUIVALENT STATIC WIND LOADS FOR TALL BUILDING DESIGN
    DAVENPORT, AG
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (02): : 463 - 467
  • [8] EQUIVALENT STATIC WIND LOADS FOR TALL BUILDING DESIGN
    PANOFSKY, HA
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (04): : 925 - 925
  • [9] EQUIVALENT STATIC WIND LOADS FOR TALL BUILDING DESIGN
    VICKERY, BJ
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (06): : 1308 - 1309
  • [10] EQUIVALENT STATIC WIND LOADS FOR TALL BUILDING DESIGN
    VELLOZZI, J
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (10): : 2068 - 2069