Calculation of beam quality correction factors for various thimble ionization chambers using the Monte Carlo code PENELOPE

被引:23
|
作者
Erazo, Fabian [1 ,2 ]
Lallena, Antonio M. [1 ]
机构
[1] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
[2] SOLCA, Inst Canc, Cuenca, Ecuador
来源
关键词
Ionization chamber perturbation factors; PENELOPE; NE2571; A19; A12S; HIGH-ENERGY PHOTON; REFERENCE DOSIMETRY; K(Q) FACTORS;
D O I
10.1016/j.ejmp.2012.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The beam quality correction factor k(Q,Q0) and the perturbation factor p(Q), commonly considered in dosimetry with ionization chambers, were calculated for the NE2571 and the Standard Imaging A19 and Al2S chambers, using the Monte Carlo simulation code PENELOPE. For the NE2571 chamber, the values of k(Q,Q0) obtained are in very good agreement with those found in previous works by Wulff et al. and Muir and Rogers with the code EGSnrc and also with the experimental results summarized in the NCS code of practice. For p(Q), a difference of similar to 0.4% has been found between our results and those obtained with EGSnrc for Co-60 and this difference increases slightly with TPR1020 values. These factors have been calculated also for the A19 and Al2S chambers of Standard Imaging. The values of k(Q,Q0) show reasonable agreement with those recently calculated by Muir and Rogers and the measurements of McEwen. (C) 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 50 条
  • [21] Validation of the Raystation Monte Carlo Code using dedicated ionization chambers
    Pittomvils, G.
    Bogaert, E.
    Thysebaert, P.
    De Wagter, C.
    Lievens, Y.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S931 - S931
  • [22] Response calculation for standard ionization chambers in the APMP using EGS4 Monte Carlo code
    Sato, Yasushi
    Yunoki, Akira
    Hino, Yoshio
    Yamada, Takahiro
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1211 - 1214
  • [23] Monte Carlo Calculation to Determine Tandem Ionization Chamber Response to X-Rays Beam Using PENELOPE
    Pianoschi, T.
    Goes, E.
    Nicolucci, P.
    Costa, A.
    Pela, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [24] Towards absolute activity measurements by ionisation chambers using the PENELOPE Monte-Carlo code
    de Vismes, A
    Amiot, MN
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (04) : 267 - 272
  • [25] Calculation of perturbation correction factors for some reference dosimeters in high-energy photon beams with the Monte Carlo code PENELOPE
    Mazurier, J
    Gouriou, J
    Chauvenet, B
    Barthe, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06): : 1707 - 1717
  • [26] Monte Carlo calculation of replacement correction factors for plane-parallel chambers
    Wang, L.
    Rogers, D. W. O.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S55 - S55
  • [27] Monte Carlo Calculation of Perturbation Correction Factors for AirFilled Ionization Chambers in Clinical Proton Beams Using TOPAS/GEANT4
    Baumann, K.
    Kaupa, S.
    Engenhart-Cabillic, R.
    Zink, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E281 - E282
  • [28] Monte Carlo calculation of perturbation correction factors for air-filled ionization chambers in clinical proton beams using TOPAS/GEANT
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 175 - 191
  • [29] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [30] Influence of Beam Quality Correction Factors on Measurement Depth in Scanning Proton Beams Using Monte Carlo Calculation
    Ichihara, M.
    Yasui, K.
    Omachi, C.
    Toshito, T.
    Nagata, J.
    Oshika, R.
    Kurata, S.
    Hayashi, N.
    MEDICAL PHYSICS, 2021, 48 (06)