Impact of Initial eGlycemic Management System Dosing Strategy on Time to Target Blood Glucose Range

被引:0
|
作者
Emamdjomeh, Amir S. [1 ]
Warren, Jamie N. [1 ]
Harper, Courtney L. [1 ]
Olin, Jacqueline L. [1 ,2 ]
机构
[1] Novant Hlth Syst, Charlotte, NC USA
[2] Wingate Univ, Sch Pharm, Wingate, NC USA
来源
关键词
glucommander; electronic glucose management system; glycemic management; subcutaneous insulin; multiplier; custom;
D O I
10.1177/1932296821992352
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Glucommander (TM) (GM), an electronic glycemic management system, was implemented across a multi-hospital health system as the standard of care for glycemic control. GM provides insulin dosing recommendations based on patient-specific blood glucose (BG) trends after providers select either a custom dose or weight-based multiplier as the initial dosing strategy for the first 24hours. This study evaluated the impact of initial subcutaneous (SC) GM insulin dosing strategies on glycemic management. Methods: Non-intensive care unit patients treated with SC GM using either initial custom (based on provider discretion) or weight-based multiplier settings (0.3, 0.5, or 0.7units/kg/day) were evaluated in this retrospective chart review. The primary endpoint was time to target BG range defined as time to first two consecutive in range point of care BG. Secondary endpoints included percentage of BG values in target range, percentage of orders following institutional recommendations, length of stay (LOS), average BG, and incidence of hypoglycemia and hyperglycemia. Results: A review of 348 patients showed time to target BG was not significantly different between custom and multiplier groups (55 vs 64hours, P = .07). Target BG was achieved in less than half of patients in both groups (47% vs 44%, respectively). There were no differences in hospital LOS, proportion of BG in target range, rates of hypo/hyperglycemia, and average BG. Conclusions: Custom initial SC GM insulin dosing settings showed a nonsignificant decrease in time to target BG range compared to pre-defined multiplier settings. Future studies evaluating the impact of compliance with institutional recommendations on BG control are warranted.
引用
收藏
页码:242 / 250
页数:9
相关论文
共 50 条
  • [31] Effectiveness of Blood Glucose Time in Range to Reduce Risk of Blood Glucose Extrusion and Improve Blood Glucose Metrics in Type 1 Diabetic Patients
    Oraibi, Omar
    Somaili, Mohammed
    Elmakki, Erwa
    Alqassimi, Sameer
    Madkhali, Mohammed Ali
    Mohrag, Mostafa
    Abusageah, Faisal
    Alhazmi, Mohammed
    Alfaifi, Samar
    Ageeli, Ruba
    Sumayli, Mohammed
    Arishi, Fatimah
    Alhazmi, Abdulaziz H.
    Hummadi, Abdulrahman
    ENDOCRINE METABOLIC & IMMUNE DISORDERS-DRUG TARGETS, 2024, 24 (10) : 1197 - 1203
  • [32] Impact of Lowest Measured Capillary Blood Glucose and Time Spent in the Hypoglycemic Range on Mortality in Hospital Attendees with Diabetes
    Jones, Gregory C.
    Sainsbury, Christopher A.
    DIABETES, 2014, 63 : A561 - A561
  • [33] Early achievement of target cyclosporine levels during initial post-transplant period with a novel dosing strategy
    Chueh, SC
    Lai, MK
    TRANSPLANTATION PROCEEDINGS, 1998, 30 (05) : 1681 - 1682
  • [34] Time in Target Range: the Future of Assessing Adequacy of Blood Pressure Control?
    Schlaich, Markus P.
    HYPERTENSION, 2023, 80 (02) : 314 - 315
  • [35] Association of time in blood glucose range with outcomes following cardiac surgery
    Omar, Amr S.
    Salama, Ahmed
    Allam, Mahmoud
    Elgohary, Yasser
    Mohammed, Shaban
    Tuli, Alejandro Kohn
    Singh, Rajvir
    BMC ANESTHESIOLOGY, 2015, 15
  • [36] Association of time in blood glucose range with outcomes following cardiac surgery
    Amr S Omar
    Ahmed Salama
    Mahmoud Allam
    Yasser Elgohary
    Shaban Mohammed
    Alejandro Kohn Tuli
    Rajvir Singh
    BMC Anesthesiology, 15
  • [37] TIME IN TARGET GLUCOSE RANGE AND GLYCATED HEMOGLOBIN LEVELS DURING THE MINIMED 670G SYSTEM PIVOTAL TRIALS
    Shin, J.
    Liu, M.
    Chen, X.
    Cordero, T.
    Lee, S.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A85 - A86
  • [38] Management of Blood Transfusion in Aortic Valve Surgery: Impact of a Blood Conservation Strategy
    Yaffee, David W.
    Smith, Deane E., III
    Ursomanno, Patricia A.
    Hill, Fredrick T.
    Galloway, Aubrey C.
    DeAnda, Abe
    Grossi, Eugene A.
    ANNALS OF THORACIC SURGERY, 2014, 97 (01): : 95 - 101
  • [39] EVALUATION OF THE IMPACT OF A CHANGE IN TARGET BLOOD GLUCOSE RANGE IN CRITICALLY ILL PATIENTS RECEIVING INTRAVENOUS INSULIN AT A LARGE ACADEMIC MEDICAL CENTER
    Allen, John
    Glass, Maresa
    Alexander, Earnest
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U231 - U231
  • [40] Impact of the use of a smartphone-based blood glucose management system within a maternal diabetes service
    Hyams, Elizabeth
    Brackenridge, Anna
    White, Sara L.
    PRACTICAL DIABETES, 2024, 41 (03) : 16 - 23