Experimental Study of Post-fire Performance of Ceramsite Concrete Filled Steel Tabular Columns

被引:2
|
作者
Wang, Xintang [1 ]
Yin, Jie [1 ]
Zhou, Ming [1 ]
Wang, Jianmin [1 ]
机构
[1] Ningbo Univ, Fac Architectural Civil Engn & Environm, Ningbo 315211, Zhejiang, Peoples R China
关键词
Ceramsite Concrete; Steel tabular column; Post-fire performance; Experiment;
D O I
10.4028/www.scientific.net/AMM.71-78.3733
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The post-fire performance of a set of ceramsite concrete filled steel tabular short columns (noted as CCSSC) after exposure to fire are experimentally studied. Effect of the maximum value of fire response temperatures and geometrical parameters of the composite columns on the strength and ductility of the specimens were especially discussed. The test results show that the specimens of CCSSC have higher post-fire bearing capacity and better ductility, and both of maximum response temperature and geometrical parameters of the specimens presented here have great effect on the post-fire bearing capacity and ductility of ceramsite concrete-filled steel short columns after exposure to fire.
引用
收藏
页码:3733 / 3736
页数:4
相关论文
共 50 条
  • [41] Study of Post-fire Behavior of a Profiled Sheet-Ceramsite Concrete Composite Floor
    Wang, Xintang
    Zhou, Ming
    Sun, Pingxin
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 1857 - 1860
  • [42] Experimental and numerical study on the performance of hollow and concrete-filled elliptical steel columns subjected to severe fire
    Ali, Faris
    Nadjai, Ali
    Goodfellow, N.
    FIRE AND MATERIALS, 2016, 40 (04) : 635 - 652
  • [43] Post-fire behaviour and resistances of square recycled aggregate concrete-filled stainless steel tube stub columns
    Wang, Ziyi
    Zhong, Yukai
    Jiang, Ke
    Su, Meini
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2024, 197
  • [44] Study on the post-fire axial compressive performance of the lightweight ceramsite foamed concrete sandwich composite shear wall
    Liu, Chunyang
    Su, Jing
    Li, Zhenbao
    Luan, Kaiye
    Zhou, Guangkai
    STRUCTURES, 2023, 58
  • [45] Study on fire-resistance performance of reinforced concrete filled steel tubular columns
    Han, Jinsheng
    Dong, Yuli
    Xu, Zhaodong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (SUPPL. 2): : 265 - 270
  • [46] Post-fire mechanical behaviour of ultra-high-performance concrete-filled steel tube (UHPCFST) stub columns under compression
    Wang, Tan
    Yu, Min
    Zhang, Xipeng
    Cheng, Shanshan
    Liu, Sumei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [47] Fire performance of concrete filled steel tubular beam-columns
    Han, LH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (06) : 695 - 709
  • [48] Fire Performance of Steel Tubular Columns Filled with Normal Strength Concrete
    Szymkuc, Wojciech
    Glema, Adam
    Malendowski, Michal
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 865 - 872
  • [49] Experimental study on steel-reinforced concrete-filled steel tubular columns under the fire
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    Du, Er-Feng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185 (185)
  • [50] Experimental study on the seismic performance of concrete filled steel tubular laced columns
    Huang, Zhi
    Jiang, Li-Zhong
    Chen, Y. Frank
    Luo, Yao
    Zhou, Wang-Bao
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (06): : 719 - 731