Hydrogen peroxide biosensor based on DNA-Hb modified gold electrode

被引:40
|
作者
Kafi, AKM
Yin, F
Shin, HK
Kwon, YS
机构
[1] Dong A Univ, Dept Port & Logist Syst, Pusan 604714, South Korea
[2] Dong A Univ, Dept Elect Engn, Pusan 604714, South Korea
关键词
DNA; hemoglobin; gold electrode; biosensor;
D O I
10.1016/j.tsf.2005.06.073
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A hydrogen peroxide (H2O2) biosensor based on DNA-hemoglobin (Hb) modified electrode is described in this paper. The sensor was designed by DNA and hemoglobin dropletting onto gold electrode surface layer by layer. The sensor based on the direct electron transfer of iron of hemoglobin showed a well electrocatalytic response to the reduction of the H2O2. This sensor offered an excellent electrochemical response for H2O2 concentration below micromole level with high sensitivity and selectivity and short response time. Experimental conditions influencing the biosensor performance such as, pH, potential were optimized and assessed. The levels of the RSD's (< 5%) for the entire analyses reflected the highly reproducible sensor performance. Using the optimized conditions the linearity for the detection of the H2O2 was observed from 10 to 120 mu M with the detection limit of 0.4 mu M (based on the S/N=3). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:420 / 424
页数:5
相关论文
共 50 条
  • [1] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Min-Jung Song
    Sung Woo Hwang
    Dongmok Whang
    [J]. Journal of Applied Electrochemistry, 2010, 40 : 2099 - 2105
  • [2] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2099 - 2105
  • [3] Amperometric biosensor for hydrogen Hemoglobin/DNA/Poly-2,6-pyridinediamine peroxide based on modified gold electrode
    Tong, Zhongqiang
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    Xie, Yi
    [J]. THIN SOLID FILMS, 2007, 515 (20-21) : 8054 - 8058
  • [4] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    [J]. Microchimica Acta, 2012, 176 : 279 - 285
  • [5] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [6] A novel amperometric hydrogen peroxide biosensor based on pyrrole-PAMAM dendrimer modified gold electrode
    Senel, Mehmet
    Cevik, Emre
    [J]. CURRENT APPLIED PHYSICS, 2012, 12 (04) : 1158 - 1165
  • [7] A Novel Electrochemical Biosensor Based on a Modified Gold Electrode for Hydrogen Peroxide Determination in Different Beverage Samples
    Navid Nasirizadeh
    Saeedeh hajihosseini
    Zahra Shekari
    Masoud Ghaani
    [J]. Food Analytical Methods, 2015, 8 : 1546 - 1555
  • [8] A Novel Electrochemical Biosensor Based on a Modified Gold Electrode for Hydrogen Peroxide Determination in Different Beverage Samples
    Nasirizadeh, Navid
    hajihosseini, Saeedeh
    Shekari, Zahra
    Ghaani, Masoud
    [J]. FOOD ANALYTICAL METHODS, 2015, 8 (06) : 1546 - 1555
  • [9] A hydrogen peroxide biosensor based on nano-Au/PAMAM dendrimer/cystamine modified gold electrode
    Liu, ZM
    Yang, Y
    Wang, H
    Liu, YL
    Shen, GL
    Yu, RQ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01) : 394 - 400
  • [10] Hydrogen peroxide biosensor based on hemoglobin-modified gold nanoparticles-screen printed carbon electrode
    Elewi, Ali Saad
    Al-Shammaree, Shatha Abdul Wadood
    Kareem, Abdul M. A.
    Sammarraie, A. L.
    [J]. SENSING AND BIO-SENSING RESEARCH, 2020, 28