Hydrogen peroxide biosensor based on hemoglobin-modified gold nanoparticles-screen printed carbon electrode

被引:32
|
作者
Elewi, Ali Saad [1 ]
Al-Shammaree, Shatha Abdul Wadood [1 ]
Kareem, Abdul M. A. [1 ]
Sammarraie, A. L. [1 ]
机构
[1] Univ Baghdad, Dept Chem, Coll Sci, Baghdad, Iraq
关键词
Hydrogen peroxide biosensor; Screen-printed carbon electrode; Gold nanoparticles; Hemoglobin direct electrochemistry; BY-LAYER FILMS; DIRECT ELECTROCHEMISTRY; HORSERADISH-PEROXIDASE; HEME-PROTEINS; SILVER NANOPARTICLES; ELECTROCATALYSIS; NANOCOMPOSITE; NANOTUBES; GRAPHENE; REDUCTION;
D O I
10.1016/j.sbsr.2020.100340
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor based on hemoglobin immobilized on screen-printed carbon electrode (SPCE) pre-electrodeposited with gold nanoparticles (AuNPs) was developed to measure hydrogen peroxide (H2O2) concentration. Cyclic voltammetry method was utilized for AuNPs electrodeposition process and characterized the Hb behaviour in the modified electrode. The highest electro active surface area (0.07 cm(2)) of working electrode in SPCE was obtained when the potential was swept (in electrodeposition experiment) from 0 to +1 V for 15 cycles in phosphate buffer solution (PBS) (pH 7) containing 0.1 nM AuNPs. Direct electrochemical of hemoglobin in the modified electrode showed quasi-reversible redox behaviour at -0.2 V and -0.3 V on forward and revers scan respectively, in PBS (pH 7) at scan rate 0.05 Vs(-1) vs. Ag/AgCl. The modified electrode was used to measure hydrogen peroxide concentration with a linear response over 3 mu M to 240 mu M and a detection limit of 0.6 mu M at -0.35 V. The apparent Michaelis-Menten constant value of Hb in the modified SPCE to measure H2O2 was calculated to be 235 mu M with sensitivity of 0.918 AM(-1) cm(-2). The surface morphology of the SPCE and its modification were investigated using Atomic Force Microscope (AFM). As a result, the new modified biosensor exhibited a high sensitivity, good reproducibility and stability.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Disposable biosensor based on a hemoglobin colloidal gold-modified screen-printed electrode for determination of hydrogen-peroxide
    Xu, XX
    Liu, SQ
    Ju, HX
    [J]. IEEE SENSORS JOURNAL, 2004, 4 (04) : 390 - 394
  • [2] Development of a peroxide biosensor made of a thiolated-viologen and hemoglobin-modified gold electrode
    Kafi, A. K. M.
    Lee, Dong-Yun
    Park, Sang-Hyun
    Kwon, Young-Soo
    [J]. MICROCHEMICAL JOURNAL, 2007, 85 (02) : 308 - 313
  • [3] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574
  • [4] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    [J]. Microchimica Acta, 2012, 176 : 279 - 285
  • [5] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [6] Hydrogen Peroxide Biosensor based on Carbon Paste Modified Electrode with Hemoglobin and Copper(II) Oxide Nanoparticles
    Abbasi, Amin
    Shamsazar, Ali
    Shamsazar, Fatemeh
    Asadi, Asadollah
    Shamsaldini, Soghra
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (04): : 3986 - 3996
  • [7] Design and development of a highly stable hydrogen peroxide biosensor on screen printed carbon electrode based on horseradish peroxidase bound with gold nanoparticles in the matrix of chitosan
    Tangkuaram, Tanin
    Ponchio, Chatchai
    Kangkasomboon, Thippayawadee
    Katikawong, Panadda
    Veerasai, Waret
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10): : 2071 - 2078
  • [8] Ultrasensitive cholesterol biosensor based on enzymatic silver deposition on gold nanoparticles modified screen-printed carbon electrode
    Huang, Yong
    Cui, Lijie
    Xue, Yewei
    Zhang, Songbai
    Zhu, Nixuan
    Liang, Jintao
    Li, Guiyin
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 77 : 1 - 8
  • [9] Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on Au@Ag Nanoparticles Modified Carbon Ionic Liquid Electrode
    Xia, Fa-Feng
    Xiao, Guo-Rong
    Ma, Chun-Yang
    Ma, Chun-Hua
    Chu, Dian-Qing
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (04) : 359 - 365
  • [10] Amperometric Biosensor for Hydrogen Peroxide Based on Direct Electrocatalysis by Hemoglobin Immobilized on Gold Nanoparticles/ 1,6-Diaminohexane Modified Glassy Carbon Electrode
    Mingyu Tang
    Shihong Chen
    Ruo Yuan
    Yaqin Chai
    Fengxian Gao
    Yi Xie
    [J]. Analytical Sciences, 2008, 24 : 487 - 491