Pelvic circumferential compression devices (PCCDs): a best evidence equipment review

被引:4
|
作者
Bryson, D. J. [1 ,2 ,3 ]
Davidson, R. [2 ,4 ]
Mackenzie, R. [2 ,5 ]
机构
[1] Leicester Royal Infirm, Trauma & Orthopaed CT2, Leicester, Leics, England
[2] Leicester Royal Infirm, Emergency Dept, Leicester LE1 5WW, Leics, England
[3] Univ Hosp Leicester, Leicester Royal Infirm, Dept Trauma & Orthopaed, Leicester, Leics, England
[4] Lincoln Cty Hosp, Emergency Dept, Lincoln, Lincs, England
[5] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Emergency Dept, Cambridge, England
关键词
Pelvic trauma; Fracture; ATLS; Circumferential compression; Pelvic binders; FRACTURES; STABILIZATION;
D O I
10.1007/s00068-012-0180-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Traumatic disruption of the pelvis can lead to significant morbidity and mortality. ATLS(A (R)) guidance advocates temporary stabilisation or 'closure' of the disrupted pelvis with a compression device or sheet. We undertook a best evidence equipment review to assess the ease and efficacy of the application of two leading commercially available devices, the T-PODA (R) and the SAM Pelvic Sling (TM) II. Fifty health care professionals and medical students participated in pelvic circumferential compression device (PCCD) education and assessment. Participants received a 10-min lecture on the epidemiology and aetiology of pelvic fractures and the principles of circumferential compression, followed by a practical demonstration. Three volunteers acted as trauma victims. Assessment included the time taken to secure the devices and whether this was achieved correctly. All participants completed a post-assessment survey. Both devices were applied correctly 100% of the time. The average time taken to secure the SAM Pelvic Sling (TM) II was 18 s and for the T-PODA (R), it was 31 s (p a parts per thousand currency sign 0.0001). Forty-four participants (88%) agreed or strongly agreed that the SAM Pelvic Sling (TM) II was easy to use compared to 84% (n = 42) for the T-PODA (R). Thirty-nine participants (78%) reported that they preferred and, given the choice in the future, would select the T-PODA (R) over the SAM Pelvic Sling (TM) II (n = 11, 22%). The results of this study indicate that both PCCDs are easy and acceptable to use and, once learned, can be applied easily and rapidly. Participants applied both devices correctly 100% of the time, with successful application taking, on average, less than 60 s.
引用
收藏
页码:439 / 442
页数:4
相关论文
共 50 条
  • [21] Imposter or knight in shining armor? Pelvic circumferential compression devices (PCCD) for severe pelvic injuries in patients with multiple trauma: a trauma-registry analysis
    H. Trentzsch
    R. Lefering
    U. Schweigkofler
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 32
  • [22] Imposter or knight in shining armor? Pelvic circumferential compression devices (PCCD) for severe pelvic injuries in patients with multiple trauma: a trauma-registry analysis
    Trentzsch, H.
    Lefering, R.
    Schweigkofler, U.
    TraumaRegister DGU
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2024, 32 (01):
  • [23] Application of Circumferential Compression Device (Binder) in Pelvic Injuries: Room for Improvement
    Vaidya, Rahul
    Roth, Matthew
    Zarling, Bradley
    Zhang, Sarah
    Walsh, Christopher
    Macsuga, Jessica
    Swartz, John
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (06) : 766 - 774
  • [24] Noninvasive reduction of open-book pelvic fractures by circumferential compression
    Bottlang, M
    Simpson, T
    Sigg, J
    Krieg, JC
    Madey, SM
    Long, WB
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (06) : 367 - 373
  • [25] Emergent stabilization of pelvic ring injuries by controlled circumferential compression: A clinical trial
    Krieg, JC
    Mohr, M
    Ellis, TJ
    Simpson, TS
    Madey, SM
    Bottlang, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (03): : 659 - 664
  • [26] Pelvic circumferential compression in the presence of soft-tissue injuries: A case report
    Krieg, JC
    Mohr, M
    Mirza, AJ
    Bottlang, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (02): : 468 - 470
  • [27] THE CONCEALMENT OF SIGNIFICANT PELVIC INJURIES ON COMPUTED TOMOGRAPHY EVALUATION BY PELVIC COMPRESSION DEVICES
    Clements, Jenny
    Jeavons, Richard
    White, Craig
    McMurtry, Ian
    JOURNAL OF EMERGENCY MEDICINE, 2015, 49 (05): : 675 - 678
  • [28] Prehospital use of pelvic circumferential compression devices in a physician-based emergency medical service: A 6-year retrospective cohort study
    Zingg, Tobias
    Piaget-Rossel, Romain
    Steppacher, Julie
    Carron, Pierre-Nicolas
    Dami, Fabrice
    Borens, Olivier
    Albrecht, Roland
    Darioli, Vincent
    Taff, Patrick
    Maudet, Ludovic
    Pasquier, Mathieu
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [29] Prehospital use of pelvic circumferential compression devices in a physician-based emergency medical service: A 6-year retrospective cohort study
    Tobias Zingg
    Romain Piaget-Rossel
    Julie Steppacher
    Pierre-Nicolas Carron
    Fabrice Dami
    Olivier Borens
    Roland Albrecht
    Vincent Darioli
    Patrick Taffé
    Ludovic Maudet
    Mathieu Pasquier
    Scientific Reports, 10
  • [30] Improving the improvisational pelvic circumferential compression technique for open-book pelvic fractures using a simulation model and a sphygmomanometer
    Rega, Paul Patrick
    Fink, B.
    Sexton, M.
    Schneiderman, J.
    Kakish, E.
    McKenzie, N.
    Kenney, K.
    Jones, C.
    BMJ MILITARY HEALTH, 2020, 166 (0E) : E21 - E24