We report on the performance of a widely tunable continuous wave mode-hop-free external-cavity quantum cascade laser operating at lambda similar to 5.2 mu m combined with cavity ring-down spectroscopy (CRDS) technique for high-resolution molecular spectroscopy. The CRDS system has been utilized for simultaneous and molecule-specific detection of several environmentally and bio-medically important trace molecular species such as nitric oxide, nitrous oxide, carbonyl sulphide and acetylene (C2H2) at ultra-low concentrations by probing numerous rotationally resolved ro-vibrational transitions in the mid-IR spectral region within a relatively small spectral range of similar to 0.035 cm(-1). This continuous wave external-cavity quantum cascade laser-based multi-component CRDS sensor with high sensitivity and molecular specificity promises applications in environmental sensing as well as non-invasive medical diagnosis through human breath analysis.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Saturated cavity ring-down spectroscopy of 12C16O2 near 1.57 μm
    Jiang, Shan
    Tan, Yan
    Liu, An-Wen
    Zhou, Xiao-Guo
    Hu, Shui-Ming
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2024, 37 (01) : 13 - 18
  • [42] Using a DS-DBR laser for widely tunable near-infrared cavity ring-down spectroscopy
    Whittaker, K. E.
    Ciaffoni, L.
    Hancock, G.
    Hurst, P. L.
    Peverall, R.
    Ritchie, G. A. D.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 116 (01): : 157 - 168
  • [43] Using a DS-DBR laser for widely tunable near-infrared cavity ring-down spectroscopy
    K. E. Whittaker
    L. Ciaffoni
    G. Hancock
    P. L. Hurst
    R. Peverall
    G. A. D. Ritchie
    Applied Physics B, 2014, 116 : 157 - 168
  • [44] Infrared near-field spectroscopy of trace explosives using an external cavity quantum cascade laser
    Craig, Ian M.
    Taubman, Matthew S.
    Lea, A. Scott
    Phillips, Mark C.
    Josberger, Erik E.
    Raschke, Markus B.
    OPTICS EXPRESS, 2013, 21 (25): : 30401 - 30414
  • [45] Cavity ring-down spectroscopy of 15N enriched N2O near 1.56 μm
    Liu, A-W
    Hu, C-L
    Wang, J.
    Perevalov, V., I
    Hu, S-M
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2019, 232 : 1 - 9
  • [46] The self- and foreign-absorption continua of water vapor by cavity ring-down spectroscopy near 2.35 μm
    Mondelain, D.
    Vasilchenko, S.
    Cermak, P.
    Kassi, S.
    Campargue, A.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2015, 17 (27) : 17762 - 17770
  • [47] An EC-QCL based N2O sensor at 5.2 μm using cavity ring-down spectroscopy for environmental applications
    Banik, Gourab Dutta
    Som, Suman
    Maity, Abhijit
    Pal, Mithun
    Maithani, Sanchi
    Mandal, Santanu
    Pradhan, Manik
    ANALYTICAL METHODS, 2017, 9 (15) : 2315 - 2320
  • [48] Cavity ring-down spectroscopy using an EC-QCL operating at 7.5 μm for direct monitoring of methane isotopes in air
    Maity, Abhijit
    Pal, Mithun
    Banik, Gourab Dutta
    Maithani, Sanchi
    Pradhan, Manik
    LASER PHYSICS LETTERS, 2017, 14 (11)
  • [49] High resolution spectroscopy of silane with an external-cavity quantum cascade laser: Absolute line strengths of the v3 fundamental band at 4.6 μm
    van Helden, J. H.
    Lopatik, D.
    Nave, A.
    Lang, N.
    Davies, P. B.
    Roepcke, J.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 151 : 287 - 294
  • [50] Sensitive trace gas detection with cavity enhanced absorption spectroscopy using a continuous wave external-cavity quantum cascade laser (vol 103, 131114, 2013)
    van Helden, J. H.
    Lang, N.
    Macherius, U.
    Zimmermann, H.
    Roepcke, J.
    APPLIED PHYSICS LETTERS, 2014, 104 (09)