Effect of norepinephrine on blood volume , cardiac output, and systemic filling pressure in patients undergoing liver transplantation

被引:1
|
作者
Mukhtar, Ahmed M. [1 ,5 ]
Fahmy, Ehab T. [1 ]
Eladawy, Akram A. [1 ]
Ali, Mohamed [1 ]
Elayashy, Mohamed [2 ]
Saner, Fuat [3 ]
Abdelaal, Amr [4 ]
Abdo, Mostafa [4 ]
Hussein, Amr S. [2 ]
机构
[1] Cairo Univ, Cairo, Egypt
[2] Cairo Univ, Kasralainy Fac Med, Anesthesia Surg ICU & Pain Management, Cairo, Egypt
[3] Univ Hosp Essen, Dept Gen Visceral& Transplantat Surg, Essen, Germany
[4] Ain Shams Univ, Cairo, Egypt
[5] 1 Saray St El Manial, Cairo, Egypt
关键词
Norepinephrine; Liver transplantation; Cardiac outoput; VENOUS RETURN; HEMODYNAMICS; CIRCULATION;
D O I
10.23736/S0375-9393.22.16526-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Patients with liver cirrhosis develop symptoms comparable to those of patients with sepsis, who have increased total vascular compliance, which may cause blood pooling in the venous pool. No previous studies have evaluated the effect of using norepinephrine on the intravascular blood volume. We investigated the norepinephrine infusion's effect on the mean systemic filling pressure, venous return, and cardiac preload in patients undergoing liver transplantation. METHODS: Overall, 33 patients who underwent living donor liver transplantation were included in this study. Cardiac output (CO) was measured using a PiCCO device (Pulsion Medical Systems, Munich, Germany). The mean systemic filling pressure was calculated using the inspiratory hold maneuver at four time intervals -at baseline, 10 min after the norepinephrine infusion, 5 min after norepinephrine discontinuation, and after infusion of 500 cc of 5% albumin. Other hemodynamic parameters, including the mean arterial pressure (MAP), pulse pressure variation, stroke volume variation, global end-diastolic volume, and mitral inflow velocity (E wave), were also evaluated. RESULTS: The norepinephrine infusion increased MAP and systemic vascular resistance in all patients. Moreover, it increased CO, mean systemic filling pressure, and global end-diastolic volume in 20 patients (60%), whereas there were no changes in these variables in 13 patients (40%). In all patients, norepinephrine infusion discontinuation caused a significant decrease in MAP, CO, resistance to venous return, and mean systemic filling pressure. Infusion of 500 cc colloid increased CO; however, interestingly, it was associated with a significant decrease in systemic vascular resistance; hence, MAP and mean systemic filling pressure showed no changes. CONCLUSIONS: The norepinephrine infusion at 0.1 mu g(-1) kg(-1) min(-1 )was associated with an increase in CO in patients with liver cirrhosis undergoing liver transplantation. Norepinephrine's effect on CO was primarily attributable to an increase in venous return due to an increase in mean systemic filling pressure.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 50 条
  • [31] The comparison between stroke volume variation and filling pressure as an estimate of right ventricular preload in patients undergoing renal transplantation
    Toyoda, Daisuke
    Fukuda, Mitsue
    Iwasaki, Ririko
    Terada, Takashi
    Sato, Nobukazu
    Ochiai, Ryoichi
    Kotake, Yoshifumi
    JOURNAL OF ANESTHESIA, 2015, 29 (01) : 40 - 46
  • [32] The comparison between stroke volume variation and filling pressure as an estimate of right ventricular preload in patients undergoing renal transplantation
    Daisuke Toyoda
    Mitsue Fukuda
    Ririko Iwasaki
    Takashi Terada
    Nobukazu Sato
    Ryoichi Ochiai
    Yoshifumi Kotake
    Journal of Anesthesia, 2015, 29 : 40 - 46
  • [33] Early atherosclerotic and cardiac damage in patients undergoing liver transplantation
    Pisano, Giuseppina
    Oberti, Giovanna
    Orlandi, Michela
    Zannoni, Stefania
    Lombardi, Rosa
    Donato, Maria F.
    Bertelli, Cristina
    Porzio, Marianna
    Caccamo, Lucio
    Dondossola, Daniele
    Colombo, Massimo
    Fargion, Silvia
    Fracanzani, Anna Ludovica
    HEPATOLOGY, 2017, 66 : 922A - 922A
  • [34] Comparison of the USCOM ultrasound cardiac output monitor with pulmonary artery catheter thermodilution in patients undergoing liver transplantation
    Wong, Lai-Sze Grace
    Yong, Boon-Hun
    Young, Karl Kong
    Lau, Lee-Sung
    Cheng, King-Lik
    Man, Jeff Siu-Fan
    Irwin, Michael G.
    LIVER TRANSPLANTATION, 2008, 14 (07) : 1038 - 1043
  • [35] EFFECT OF BLOOD VOLUME ON VENOUS PRESSURE IN CARDIAC TAMPONADE
    MORGAN, BC
    GUNTHEROTH, WG
    DILLARD, DH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1966, 51 (04): : 575 - +
  • [36] The effect of carbon arc radiation on blood pressure and cardiac output
    Johnson, JR
    Pollock, BE
    Mayerson, HS
    Laurens, H
    AMERICAN JOURNAL OF PHYSIOLOGY, 1936, 114 (03): : 594 - 602
  • [37] Stroke volume variation as a predictor of fluid responsiveness for cardiac output in patients undergoing cardiac surgery
    Klinzing, S
    Seeber, P
    Schiergens, V
    Sakka, S
    Reinhart, K
    Meier-Hellmann, A
    CRITICAL CARE MEDICINE, 2001, 29 (12) : A56 - A56
  • [38] SEROTONIN EFFECT ON CARDIAC OUTPUT AND CENTRAL BLOOD VOLUME OF ANAESTHETIZED DOG
    PAULET, G
    LEBARS, R
    BERNARD, JP
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1966, 160 (02): : 385 - &
  • [39] EFFECT OF HEMODIALYSIS ON BLOOD-VOLUME DISTRIBUTION AND CARDIAC-OUTPUT
    CHAIGNON, M
    CHEN, WT
    TARAZI, RC
    BRAVO, EL
    NAKAMOTO, S
    HYPERTENSION, 1981, 3 (03) : 327 - 332
  • [40] ACETYLCHOLINE EFFECT ON CARDIAC OUTPUT AND CENTRAL BLOOD VOLUME OF ANAESTHETIZED DOG
    PAULET, G
    LEBARS, R
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1970, 164 (02): : 400 - &